AQD - Measurement Equipment**
measurementequipment
Public draft
targajau
2024-03-14 20:58:51.0
Common
0.1
false
false
AE22-PM2.5
AE22 Aethalometer with PM2.5 cyclone
valid
2022-12-02
2022-12-02
AE31
AE31 Aethalometer
valid
2022-12-02
2022-12-02
AE33
AE33 Aethalometer
valid
2022-12-02
2022-12-02
AE33-PM2.5
AE33 Aethalometer with PM2.5 cyclone
AE33 Aethalometer with PM2.5 cyclone
valid
2022-12-02
2022-12-02
AIRTOXICA73022
Chromatotec AirTOXIC BTX PID - A73022
Using gas chromatography, the model airTOXIC BTX PID measures the amount of Benzene, Toluene, Ethylbenzene and Xylenes in the air from sub-ppb levels up to 1,000 ppb.
valid
2022-12-02
2022-12-02
ANNOX
ANNOX
valid
2022-12-02
2022-12-02
API
Teledyne API undertermined
valid
2022-12-02
2022-12-02
API100
Teledyne API 100 UV Fluorescent SO2 Analyser
valid
2022-12-02
2022-12-02
API100A
Teledyne API 100A UV Fluorescent SO2 Analyser
valid
2022-12-02
2022-12-02
API100E
Teledyne API 100E UV Fluorescent SO2 Analyser
valid
2022-12-02
2022-12-02
API101
Teledyne API 101 UV Fluorescent SO2 Analyser
valid
2022-12-02
2022-12-02
API101A
Teledyne API 101A UV Fluorescent SO2 Analyser
valid
2022-12-02
2022-12-02
API200
Teledyne API 200 chemiluminescent NOx analyser
valid
2022-12-02
2022-12-02
API200A
Teledyne API 200A chemiluminescent NOx analyser
valid
2022-12-02
2022-12-02
API200AU
TELEDYNE API 200AU
Teledyne API 200AU chemiluminescent NOx analyser
valid
2022-12-02
2022-12-02
API200E
Teledyne API 200E chemiluminescent NOx analyser
valid
2022-12-02
2022-12-02
API200EU
Teledyne API 200EU chemiluminescent NOx analyser
valid
2022-12-02
2022-12-02
API200EU-BL
Teledyne API 200EU chemiluminescent NOx analyser - blue light
valid
2022-12-02
2022-12-02
API200UP
Teledyne API 200UP chemiluminescent NOx analyser
valid
2022-12-02
2022-12-02
API201A
Teledyne API 200A chemiluminescent NOx analyser
valid
2022-12-02
2022-12-02
API300
Teledyne API 300 gas filter correlation CO analyser
valid
2022-12-02
2022-12-02
API300A
Teledyne API 300A gas filter correlation CO analyser
valid
2022-12-02
2022-12-02
API300E
Teledyne API 300E gas filter correlation CO analyser
valid
2022-12-02
2022-12-02
API400
Teledyne API 400 UV photometric O3 analyser
valid
2022-12-02
2022-12-02
API400A
Teledyne API 400A UV photometric O3 analyser
valid
2022-12-02
2022-12-02
API400E
Teledyne API 400E UV photometric O3 analyser
valid
2022-12-02
2022-12-02
APIM100E
Teledyne API M100E UV Fluorescent SO2 Analyser
valid
2022-12-02
2022-12-02
APIM200E
Teledyne API M200E chemiluminescent NOx analyser
valid
2022-12-02
2022-12-02
APIM300E
Teledyne API M300E gas filter correlation CO analyser
valid
2022-12-02
2022-12-02
APIM400E
Teledyne API M400E UV photometric O3 analyser
valid
2022-12-02
2022-12-02
APIT100
Teledyne API T100 UV Fluorescent SO2 Analyser
valid
2022-12-02
2022-12-02
APIT200
Teledyne API T200 chemiluminescent NOx analyser
valid
2022-12-02
2022-12-02
APIT200U
Teledyne API T200U chemiluminescent NOx analyser
The Model T200U Trace-level NO/NO2/NOx analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. It uses the proven chemiluminescence principle and is designed to allow ultra-sensitive measurements with a lower detectable limit of 50 ppt while still meeting the requirements for use as a US EPA compliance analyzer.
The Model T200U combines a gold plated reaction cell with an enhanced performance pump, special low noise photomultiplier tube, and unique signal conditioning to provide exceptional sensitivity. In addition, a pre-reactor separates the NO-O3 reaction from background chemiluminescence to allow accurate auto-zero of the analyzer.
All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.
The Model T200U comes NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
valid
2022-12-02
2022-12-02
APIT300
Teledyne API T300 gas filter correlation CO analyser
valid
2022-12-02
2022-12-02
APIT400
Teledyne API T400 UV photometric O3 analyser
valid
2022-12-02
2022-12-02
BAM1020
MetOne BAM-1020
valid
2022-12-02
2022-12-02
BAM1020heated
MetOne BAM-1020 heated
valid
2022-12-02
2022-12-02
BAM1020unheated
MetOne BAM-1020 unheated
valid
2022-12-02
2022-12-02
COmonitorEurope
CO Monitor Europe
CO Monitor Europe
valid
2022-12-02
2022-12-02
CP7001-BTX
Chrompack BTX CP7001 Monitor
valid
2022-12-02
2022-12-02
DELTA
DELTA
valid
2022-12-02
2022-12-02
DKK-TOA_Gu-X-113E
DKK-TOA_Gu-X-113E
This instrument provides continuous and reliable measurement of Ozone in ambient air. Measurement is based on the UV photometric method as specified in ISO-13964
valid
2022-12-02
2022-12-02
Dasibi2110A
Dasibi 2110A
For measuring NO, NO2 and NOx
valid
2022-12-02
2022-12-02
EC9852
ECOTECH EC9852
The EC9852 Sulfur Compounds Analyser combines microprocessor control with fluorescence detection and an external converter to measure H2S and SO2 or TS, TRS and SO2 or H2S, SO2 and H2S + SO2 in the range of 0-2 ppm with a detection limit of 0.5 ppb for SO2.
valid
2022-12-02
2022-12-02
Ecophysics-CLD700AL
Eco Physics CLD 700 AL
valid
2022-12-02
2022-12-02
Ecophysics-CLD780TR
Eco Physics CLD 780 TR
valid
2022-12-02
2022-12-02
Enviro1003RS
Environnement S.A. Model 1003-RS O3
Environnement S.A. Model 1003-RS under DASIBI license
valid
2022-12-02
2022-12-02
Environnement_SF8
Environnement SF8
Environnement SF8 for black smoke and acidity
valid
2023-08-25
2023-08-25
F-701-20
F-701-20 Verewa / Durag
Ambient Air Dust Concentration Monitor
valid
2022-12-02
2022-12-02
FIDAS200
Palas model FIDAS 200
valid
2022-12-02
2022-12-02
FIDAS200E
Palas model FIDAS 200E
valid
2022-12-02
2022-12-02
FIDAS200S
Palas model FIDAS 200S
valid
2022-12-02
2022-12-02
GC5000BTX-FID
AMA GC5000 BTX Type FID
valid
2022-12-02
2022-12-02
GC5000BTX-PID
AMA GC5000 BTX Type PID
valid
2022-12-02
2022-12-02
GC855BTX
SINTECH SPECTRAS BTX GC 855 series undetermined
valid
2022-12-02
2022-12-02
http://www.synspec.nl/docs/manuals/manual-3-Manual%20operator%20Syntech%20Spectras%20GC955%20600-800.pdf
GC855BTX-600
SINTECH SPECTRAS BTX GC 855 serie 600
valid
2022-12-02
2022-12-02
GC866
Chromatotec GC866
Analysis of VOC/BTEX in ambient air at very low concentration levels (ppb/ppt) thanks to precontration using a trap
valid
2022-12-02
2022-12-02
GC955
SYNTECH SPECTRAS GC 955 series undetermined
valid
2022-12-02
2022-12-02
http://www.synspec.nl/docs/manuals/manual-3-Manual%20operator%20Syntech%20Spectras%20GC955%20600-800.pdf
GC955-600
SYNTECH SPECTRAS GC 955-600
valid
2022-12-02
2022-12-02
http://www.synspec.nl/docs/manuals/manual-3-Manual%20operator%20Syntech%20Spectras%20GC955%20600-800.pdf
GC 955-601
SYNTECH SPECTRAS GC 955-601
Gas chromatograph (GC) specifically built for the measurement of BTEX in ambient air. It can be utilised to simultaneously detect and measure up to 40 different components
valid
2022-12-02
2022-12-02
GC955-800
SYNTECH SPECTRAS GC 955-800
valid
2022-12-02
2022-12-02
http://www.synspec.nl/docs/manuals/manual-3-Manual%20operator%20Syntech%20Spectras%20GC955%20600-800.pdf
GRIMM-CPC5412
GRIMM CPC model 5412 Standard Condensation Particle Counter
Compact CPC for nanoparticle counting with optimized detection efficiency and response time, with integrated sample flow pump. Different calibrations possible
valid
2024-02-08
2024-02-08
GRIMM EDM 107
GRIMM model EDM 107 for PM10, PM2.5, PM1 and TC
valid
2022-12-02
2022-12-02
http://www.grimm-aerosol.com/downloads/datasheets/en/GrimmAerosolTechnik_Enviro_EDM107.pdf
The GRIMM model 107 monitor is designed to measure particle size distribution and particulate mass based on a light scattering measurement of individual particles in the sampled air
GRIMM EDM 180
GRIMM model EDM 180 for PM10 and PM2.5
valid
2022-12-02
2022-12-02
GRIMM-EDM180C
GRIMM model EDM 180-C for PM10 and PM2.5
valid
2022-12-02
2022-12-02
GRIMM-EDM180D
GRIMM model EDM 180-D for PM10, PM2.5, PM1 and TC
valid
2022-12-02
2022-12-02
GRIMM-EDM180MC
GRIMM model EDM 180-MC for PM10, PM2.5, PM1, TC and 31 size channels
valid
2022-12-02
2022-12-02
GRIMM-EDM280
GRIMM model EDM 280 for TSP, PM10, PM4, PM2.5, PM1, PMcoarse
GRIMM model EDM 280 for TSP, PM10, PM4, PM2.5, PM1, PMcoarse
valid
2024-02-08
2024-02-08
GRIMM EDM 365
GRIMM model EDM 365 for PM10, PM2.5, PM1 and TC
valid
2022-12-02
2022-12-02
http://www.grimm-aerosol.com/downloads/datasheets/en/GrimmAerosolTechnik_Enviro_GeneralCatalogue.pdf
IL-Punkkinen
IL-Punkkinen for NO2/NO hourly measurements
Device based on the modified automated Saltzman method by Finnish Meteorological Institute.
valid
2022-12-02
2022-12-02
Leckel_SEQ47-50
Leckel SEQ47/50
valid
2023-08-25
2023-08-25
LumexRA-915AM
MERCURY MONITOR RA-915AM
RA-915AM monitors are designed for continuous mercury measurements in ambient air, indoor air and in natural gas. Ideal for permanent unattended installation at air monitoring stations, RA-915AM monitor for ambient air allows ultra-sensitive measurements of background Hg concentrations and is compliant with the European standard EN 15852 for ambient air monitoring.
The monitors feature fully-automated unattended operation without the need for the monthly technician maintenance and frequent recalibration. The use of the instrument allows cutting down operation costs as the analyzer requires no argon cylinders for operation and no consumables.
The remote data transfer makes it possible to connect the monitor to data collection systems via RS232, Modbus, and analogue output.
valid
2022-12-02
2022-12-02
LumexRA-915M
Lumex RA-915M mercury vapor analyzer
Mercury Analyzer is a portable multifunctional atomic absorption spectrometer with Zeeman background correction, which eliminates the effect of interfering impurities. It is the only high sensitivity and selectivity instrument that does not require gold amalgam pre-concentration and subsequent regeneration steps. This enables the user to conduct real time air monitoring and detection of mercury vapor. Being combined with pyrolysis or cold vapour attachments for liquid and solid sample testing, the instrument can determine mercury content in water, soil, food products, natural and stack gases, may be used for dental and toxicological applications, etc.
valid
2022-12-02
2022-12-02
ML
ML
valid
2022-12-02
2022-12-02
check pollutant
ML2010
Monitor Labs model 2010 O3 analyser
valid
2022-12-02
2022-12-02
ML2030
Monitor Labs model 2030 CO analyser
valid
2022-12-02
2022-12-02
ML2040
Monitor Labs model 2040 SO2 analyser
valid
2022-12-02
2022-12-02
ML2041
Monitor Labs model 2041 NOx analyser
valid
2022-12-02
2022-12-02
ML2050
Monitor Labs model 2050 SO2 analyser
valid
2022-12-02
2022-12-02
ML8410
Monitor Labs model 8410 NOx analyser
Monitor Labs model 8410 NOx analyser
valid
2022-12-02
2022-12-02
ML8440
Monitor Labs model 8440 NOx analyser
valid
2022-12-02
2022-12-02
check pollutant
ML8441
Monitor Labs model 8841 NOx analyser
valid
2022-12-02
2022-12-02
check pollutant
ML8810
Monitor Labs model 8810 O3 analyser
valid
2022-12-02
2022-12-02
check pollutant
ML8830
Monitor Labs model 8830 CO analyser
valid
2022-12-02
2022-12-02
check pollutant
ML8831
Monitor Labs model 8831 CO analyser
valid
2022-12-02
2022-12-02
check pollutant
ML8840
Monitor Labs model 8840 NOx analyser
valid
2022-12-02
2022-12-02
check pollutant
ML8841
Monitor Labs model 8841 NOx analyser
valid
2022-12-02
2022-12-02
check pollutant
ML8850
Monitor Labs model 8850 SO2 analyser
valid
2022-12-02
2022-12-02
check pollutant
ML8850M
Monitor Labs model 8850M SO2 analyser
valid
2022-12-02
2022-12-02
check pollutant
ML8850S
Monitor Labs model 8850S SO2 analyser
valid
2022-12-02
2022-12-02
check pollutant
ML8930
Monitor Labs model 8930 CO analyser
Monitor Labs model 8930 CO analyser
valid
2022-12-02
2022-12-02
ML8941A
Monitor Labs model 8941A NOx analyser
valid
2022-12-02
2022-12-02
check pollutant
ML9800
Monitor Labs model 9800
valid
2022-12-02
2022-12-02
check pollutant
ML9810
Monitor Labs model 9810 O3 analyser
valid
2022-12-02
2022-12-02
ML9810A
Monitor Labs model 9810A O3 analyser
valid
2022-12-02
2022-12-02
ML9810B
Monitor Labs model 9810B O3 analyser
valid
2022-12-02
2022-12-02
ML9811
Monitor Labs model 9811 O3 analyser
valid
2022-12-02
2022-12-02
ML9812
Monitor Labs model 9812 O3 analyser
valid
2022-12-02
2022-12-02
ML9830
Monitor Labs model 9830 CO analyser
valid
2022-12-02
2022-12-02
ML9830B
Monitor Labs model 9830B CO analyser
valid
2022-12-02
2022-12-02
ML9832
Monitor Labs model 9832 CO analyser
valid
2022-12-02
2022-12-02
ML9840
Monitor Labs model 9840 NOx analyser
valid
2022-12-02
2022-12-02
ML9841
Monitor Labs model 9841 NOx analyser
valid
2022-12-02
2022-12-02
ML9841A
Monitor Labs model 9841A NOx analyser
valid
2022-12-02
2022-12-02
ML9841B
Monitor Labs model 9841B NOx analyser
valid
2022-12-02
2022-12-02
ML9841T
Monitor Labs model 9841T NOx analyser
valid
2022-12-02
2022-12-02
ML9850
Monitor Labs model 9850 SO2 analyser
valid
2022-12-02
2022-12-02
ML9850B
Monitor Labs model 9850B SO2 analyser
valid
2022-12-02
2022-12-02
NIRA-Venus301
NIRA-Venus301
NIRA-Venus301
valid
2022-12-02
2022-12-02
PNS18-DM-3.1
PNS 18-DM-3.1
The PNS DM consists of a low/medium volume sampler (LVS or MVS) and a filter changer with intake tube and sampling inlet. It collects fine particulate matter on sampling filters according to EN 12341:2014 (PM10 and PM2.5).
valid
2022-12-02
2022-12-02
PNS18-DM-6.1
PNS 18-DM-6.1
The PNS DM consists of a low/medium volume sampler (LVS or MVS) and a filter changer with intake tube and sampling inlet. It collects fine particulate matter on sampling filters according to EN 12341:2014 (PM10 and PM2.5).
valid
2022-12-02
2022-12-02
PNS18T-DM-3.1
PNS 18T-DM-3.1
The PNS T-DM combines a low / medium volume sampler (LVS or MVS) and a filter changer in a stainless steel cabinet. It collects fine particulate matter on sampling filters according to EN 12341:2014 (PM10 and PM2.5).
valid
2022-12-02
2022-12-02
PNS18T-DM-6.1
PNS 18T-DM-6.1
The PNS T-DM combines a low / medium volume sampler (LVS or MVS) and a filter changer in a stainless steel cabinet. It collects fine particulate matter on sampling filters according to EN 12341:2014 (PM10 and PM2.5).
valid
2022-12-02
2022-12-02
PNS24-DM-3.1
PNS 24-DM-3.1
The PNS DM consists of a low/medium volume sampler (LVS or MVS) and a filter changer with intake tube and sampling inlet. It collects fine particulate matter on sampling filters according to EN 12341:2014 (PM10 and PM2.5).
valid
2022-12-02
2022-12-02
PNS24-DM-6.1
PNS 24-DM-6.1
The PNS DM consists of a low/medium volume sampler (LVS or MVS) and a filter changer with intake tube and sampling inlet. It collects fine particulate matter on sampling filters according to EN 12341:2014 (PM10 and PM2.5).
valid
2022-12-02
2022-12-02
PNS24T-DM-3.1
PNS 24T-DM-3.1
The PNS T-DM combines a low / medium volume sampler (LVS or MVS) and a filter changer in a stainless steel cabinet. It collects fine particulate matter on sampling filters according to EN 12341:2014 (PM10 and PM2.5).
valid
2022-12-02
2022-12-02
PNS24T-DM-6.1
PNS 24T-DM-6.1
The PNS T-DM combines a low / medium volume sampler (LVS or MVS) and a filter changer in a stainless steel cabinet. It collects fine particulate matter on sampling filters according to EN 12341:2014 (PM10 and PM2.5).
valid
2022-12-02
2022-12-02
Passive_Palmes_Tube
Passive Palmes Tube
Passive Palmes Tube. Generally for NO2. However, available for other substances like NOX-NO, SO2, O3, C6H6...
valid
2023-08-25
2023-08-25
PicarroG2401
Picarro G2401 (used for CO measurement)
valid
2022-12-02
2022-12-02
SFIO342M
SFI O342M
valid
2022-12-02
2022-12-02
SIR-S-5001
SIR S-5001
The SIR Model S-5001 is a Non-Pulsed U.V. Fluorescence Sulfur Dioxide Analyzer. In the nalyzer, optically filtered pure monochromatic U.V. light from a Zinc lamp is focused onto the SO2 reaction chamber.
valid
2022-12-02
2022-12-02
SIR-S-5006
SIR S-5006
The SIR Model S-5006 is a Non-Dispersive Infrared (NDIR) Analyzer for the measurement of Carbon Monoxide concentrations in ambient air
valid
2022-12-02
2022-12-02
SIR-S-5012
SIR S-5012
The SIR Model S-5012 Nitrogen Oxides Analyzer is designed to measure the amount of nitric oxide (NO), nitrogen dioxide (NO2) and total oxides of nitrogen (NOx) in a continuous, ambient air sample
valid
2022-12-02
2022-12-02
SIR-S-5014
SIR S-5014
SIR Model S-5014 ozone analyser is a self-contained instrument which measures the concentration of ozone in a sample of ambient background) gas, such as air, oxygen, nitrogen, etc
valid
2022-12-02
2022-12-02
SRI8610
SRI 8610
valid
2022-12-02
2022-12-02
SRI8610-C
SRI8610-C
Compact gas chromatograph
valid
2022-12-02
2022-12-02
SWAM5aDual
SWAM 5a Dual channel monitor
valid
2022-12-02
2022-12-02
SWAM5aSingle
SWAM 5a Single channel monitor
FAI SWAM5a Single Channel
valid
2022-12-02
2022-12-02
Serinus10
Serinus 10 O3
valid
2022-12-02
2022-12-02
Serinus30
Serinus30 CO
valid
2022-12-02
2022-12-02
Serinus50
Serinus 50 SO2
valid
2022-12-02
2022-12-02
TEOM1400
TEOM 1400
valid
2022-12-02
2022-12-02
assumed 1400
TEOM1400A
TEOM 1400A
valid
2022-12-02
2022-12-02
TEOM1400AB
TEOM 1400AB
valid
2022-12-02
2022-12-02
TEOM1400AB-FDMS
TEOM 1400AB with FDMS module (8500)
valid
2022-12-02
2022-12-02
must be AB
TEOM1400FDMS-8500B-CB
TEOM 1400 FDMS + 8500 B or CB Dryer
valid
2022-12-02
2022-12-02
TEOM1405
TEOM 1405
valid
2022-12-02
2022-12-02
TEOM1405D
TEOM 1405D
valid
2022-12-02
2022-12-02
TEOM1405DF-FDMS
TEOM 1405DF with FDMS Dichotomous monitor for PM2.5 & PM10
valid
2022-12-02
2022-12-02
TEOM1405F-FDMS
TEOM 1405F with FDMS
valid
2022-12-02
2022-12-02
THERMO450i
THERMO 450i
valid
2022-12-02
2022-12-02
TSI3022ACPC
TSI 3022A CPC
The Model 3022A Condensation Particle Counter detects particles down to 7 nm in diameter. Using both single-count and photometric detection modes, it provides highly accurate measurements for concentrations as high as 107particles/cm3.
valid
2022-12-02
2022-12-02
TSI3752CPC
TSI model 3752 High Concentration Condensation Particle Counter
TSI Condensation Particle Counters (CPCs)
valid
2024-02-19
2024-02-19
TSI3775CPC
TSI model 3775 Condensation Particle Counter
TSI model 3775 Condensation Particle Counter (Discontinued)
valid
2024-02-19
2024-02-19
TSI3936SMPS
TSI 3936 SMPS
valid
2022-12-02
2022-12-02
Thermo17i
Thermo 17i
The Thermo Scientific Model 17i Ammonia Analyzer uses the light producing reaction of nitric oxide (NO) with ozone (O3) as its basic principle. The instrument has three modes of operation, NO, NOx and Nt.
valid
2022-12-02
2022-12-02
Thermo49iq
THERMO49iq
With ultraviolet photometry technology. High stability and low detection limit (0.5 ppm)
valid
2022-12-02
2022-12-02
URG
URG
valid
2022-12-02
2022-12-02
VOC71M
Environnement VOC71M
valid
2022-12-02
2022-12-02
VOC72M
Environnement VOC72M
valid
2022-12-02
2022-12-02
WoesthoffU3S
Woesthoff U3S
Woesthoff U3S
valid
2022-12-02
2022-12-02
aerisAE2010U
Aeris AE2010U
The aeris® AE2010U Trace Level Ozone (03) Analyser employs a non-dispersive ultraviolet (UV) absorption
valid
2022-12-02
2022-12-02
aerisAE2030U
Aeris AE2030U
The aeris® AE2030U Trace Level Carbon monoxide (CO) analyser employs a n on-dispersive infrared (NDIR) photometer to measure very low concentrations of CO
valid
2022-12-02
2022-12-02
aerisAE2041U
Aeris AE2041U
The aeris® AE2041U Trace Level NO/NO2/NOx chemiluminescence analyser incorporates a single-channel design measuring NO and NOx
valid
2022-12-02
2022-12-02
aerisAE2050U
Aeris AE2050U
The aeris® AE2050U Trace Level Sulphur Dioxide (S02) Analyser employs pulsed UV fluorescent radiation technology
valid
2022-12-02
2022-12-02
aerodyneACSM
Aerodyne ACSM
The Aerosol Chemical Speciation Monitor (ACSM) measures mass loading and chemical composition of non-refractory aerosol particles in real-time. Smaller, lower cost, more robust, and simpler to operate than our AMS instruments, the ACSM is designed for long-term unattended deployment and routine monitoring applications.
valid
2022-12-02
2022-12-02
agilentHP6890
agilent HP 6890
Agilent HP 6890 (used for benzene and toluene measurement)
valid
2022-12-02
2022-12-02
airmoOzone
CHROMATOTEC airmOzone
System for analysis of the Ozone precursor VOC
valid
2022-12-02
2022-12-02
airmoVOC_BTX
airmoVOC BTX
The airmoVOC BTX is an automatic gas chromatograph dedicated to
the analysis and monitoring of trace amounts of BTEX compounds
(Benzene, Toluene, Ethylbenzene, m-, p-, and o-Xylenes),
valid
2022-12-02
2022-12-02
airmoVOC_BTX1000
airmotec BTX 1000
valid
2022-12-02
2022-12-02
airpointer
airpointer
The airpointer‘s modular design comprising a base unit,
analyzing modules and sensor modules allows for a configuration
according to different application requirements.
valid
2022-12-02
2022-12-02
alpha400
SYNSPEC model Alpha 400
Benzene analyser model Alpha 400
valid
2022-12-02
2022-12-02
andersenFH621N
Andersen/GMW Model FH621-N Beta Monitor
Andersen Instruments Model FH62I-N PM10 Beta Attenuation Monitor consisting of the following components: FH101 Vacuum Pump Assembly; FH102 Accessory Kit; FH107 Roof Flange Kit; FH125 Zero and Span PM 10 Mass Foil Calibration Kit; FH62I Beta Attenuation 19-inch Control Module; SA246b PM10Inlet (16.7 liter/min) or the louvered inlet specified in 40 CFR 50 Appendix L, Figs. L-2 thru L-19; operated for 24-hour average measurements, with an observing time of 60 minutes, the calibration factor set to 2400, a glass fiber filter tape, an automatic filter advance after each 24-hour sample period, and with or without either of the following options: FH0P1 Indoor Cabinet; FH0P2 Outdoor Shelter Assembly
superseded
2022-12-02
2022-12-02
Definition from US EPA
http://www.epa.gov/ttnamti1/files/ambient/criteria/reference-equivalent-methods-list.pdf
andersenFH62C14
Thermo Andersen Series FH 62 C14 Continuous PM10 Ambient Particulate Monitor
Thermo Andersen Series FH 62 C14 Continuous PM10 Ambient Particulate Monitor and Thermo Scientific Model 5014i Beta (5014i Beta), Continuous Ambient Particulate Monitor,” operated for 24-hour average measurements, with the specified 10-micron EPA PM10inlet (or alternative louvered PM10inlet meeting 40 CFR 50 Appendix L specifications), inlet connector, sample tube with heater, roof flange kit, mass foil kit, pump kit, sample filter tape; with operational settings of 1000 L/h (16.67 L/min) sample flowrate, daily filter change, auto filter change at volumetric flow <950 L/h, auto filter change at mass >1500 micrograms, and factory default calculation mode settings operated with software version 1.07. Operated, calibrated and serviced according to the appropriate Operator Manual
valid
2022-12-02
2022-12-02
Definition from US EPA
http://www.epa.gov/ttnamti1/files/ambient/criteria/reference-equivalent-methods-list.pdf
andersenFH62IN
Andersen/GMW Model FH62I-N Beta Monitor
Andersen Instruments Model FH62I-N PM10 Beta Attenuation Monitor consisting of the following components: FH101 Vacuum Pump Assembly; FH102 Accessory Kit; FH107 Roof Flange Kit; FH125 Zero and Span PM 10 Mass Foil Calibration Kit; FH62I Beta Attenuation 19-inch Control Module; SA246b PM10Inlet (16.7 liter/min) or the louvered inlet specified in 40 CFR 50 Appendix L, Figs. L-2 thru L-19; operated for 24-hour average measurements, with an observing time of 60 minutes, the calibration factor set to 2400, a glass fiber filter tape, an automatic filter advance after each 24-hour sample period, and with or without either of the following options: FH0P1 Indoor Cabinet; FH0P2 Outdoor Shelter Assembly
valid
2022-12-02
2022-12-02
Definition from US EPA
http://www.epa.gov/ttnamti1/files/ambient/criteria/reference-equivalent-methods-list.pdf
andersenFH62IR
Thermo Andersen ESM FH 62 I-R
valid
2022-12-02
2022-12-02
http://www.epa.gov/ttnamti1/files/ambient/criteria/reference-equivalent-methods-list.pdf
andersenGPS-1-modif
Modified Andersen GPS-1 sampler
valid
2022-12-02
2022-12-02
andersenHVS
Andersen/GMW generic High-Volume Air Sampler
valid
2022-12-02
2022-12-02
aurora3000
Aurora nephelometer 3000
3 WAVELENGTH INTEGRATING NEPHELOMETER
Aerosol particles in the atmosphere directly influence the earth’s radiative balance by absorbing and scattering the solar radiation and indirectly, by changing the clouds microphysical properties."
valid
2022-12-02
2022-12-02
bendix8101c
Bendix/Combustion Engineering Model 8101-C Oxides of Nitrogen Analyze
Bendix or Combustion Engineering Model 8101-C Oxides of Nitrogen Analyzer operated on a 0-0.5 ppm range with a Teflon sample filter (Bendix P/N 007163) installed on the sample inlet line.
valid
2022-12-02
2022-12-02
Definition from US EPA
http://www.epa.gov/ttnamti1/files/ambient/criteria/reference-equivalent-methods-list.pdf
csi1600
Columbia Scientific Industries Models 1600
CSI Model 1600 Oxides of Nitrogen Analyzer operated on a 0-0.5 ppm range with a Teflon sample filter (CSI P/N M951-8023)installed on the sample inlet line
valid
2022-12-02
2022-12-02
Definition from US EPA
http://www.epa.gov/ttnamti1/files/ambient/criteria/reference-equivalent-methods-list.pdf
csi5600
Columbia Scientific Industries Models 5600
CSI Model 5600 Oxides of Nitrogen Analyzer operated on a 0-0.5 ppm range, with any signal integration time in the range of 20 to 99 seconds, with a Teflon sample filter (CSI P/N M951-8023) installed on the sample inlet line
valid
2022-12-02
2022-12-02
Definition from US EPA
http://www.epa.gov/ttnamti1/files/ambient/criteria/reference-equivalent-methods-list.pdf
dasibi
DASIBI
valid
2022-12-02
2022-12-02
check pollutant
dasibi1003
DASIBI 1003 O3 analyser
valid
2022-12-02
2022-12-02
dasibi1003PC
DASIBI 1003-PC O3 analyser
valid
2022-12-02
2022-12-02
dasibi1003RS
DASIBI 1003-RS O3 analyser
valid
2022-12-02
2022-12-02
dasibi1008
DASIBI 1008 O3 analyser
valid
2022-12-02
2022-12-02
dasibi1008AH
DASIBI 1008-AH O3 analyser
valid
2022-12-02
2022-12-02
dasibi1008PC
DASIBI 1008-PC O3 analyser
valid
2022-12-02
2022-12-02
dasibi1008RS
DASIBI 1008-RS O3 analyser
valid
2022-12-02
2022-12-02
dasibi1108
DASIBI 1108 O3 analyser
valid
2022-12-02
2022-12-02
dasibi2108
DASIBI 2108 NOx analyser
valid
2022-12-02
2022-12-02
dasibi3008
DASIBI 3008 CO analyser
valid
2022-12-02
2022-12-02
dasibi4108
DASIBI 4108 SO2 analyser
valid
2022-12-02
2022-12-02
dasibi5014
DASIBI 5014
valid
2022-12-02
2022-12-02
check pollutant
dasibi7001
DASIBI 7001
valid
2022-12-02
2022-12-02
check pollutant
eberlineFH62-1
EBERLINE model FH 62-1
Beta-absorption method PM10 analyser
valid
2022-12-02
2022-12-02
enrivoAC21M
Environnement S.A. Model AC21M NO2 Analyzer
valid
2022-12-02
2022-12-02
check pollutant
enrivoAC30M
Environnement S.A. Model AC30M NO2 Analyzer
valid
2022-12-02
2022-12-02
enrivoAC31M
Environnement S.A. Model AC31M NO2 Analyzer
Environnement S. A. Model AC31M Chemiluminescent Nitrogen Oxide Analyzer operated with a full scale range of 0 -500ppb, at any temperature in the range of 15°C to 35°C, with a 5-micron PTFE sample particulate filter, with the following software settings: Automatic response time ON; Minimum response time set to 60 seconds (RT 2); and with or without any of the following options: Internal Permeation Oven; Connection for Silica Gel Dryer; RS232-422 interface; EV3 valve; Internal Printer
valid
2022-12-02
2022-12-02
Definition from US EPA
http://www.epa.gov/ttnamti1/files/ambient/criteria/reference-equivalent-methods-list.pdf
enrivoAC32E
Environnement S.A. Model AC32E NO2 Analyzer
Environnement S.A. Model AC32E NO2 Analyzer
valid
2022-12-02
2022-12-02
enrivoAC32M
Environnement S.A. Model AC32M NO2 Analyzer
Environnement S. A. Model AC32M Chemiluminescent Nitrogen Oxides Analyzer operated with a full scale range of 0 -500 ppb, at any temperature in the range of 10°C to 35°C, with a 5-micron PTFE sample particulate filter, with response time setting 11 (automatic response time), and with or without the following option:Internal permeation oven.
valid
2022-12-02
2022-12-02
Definition from US EPA
http://www.epa.gov/ttnamti1/files/ambient/criteria/reference-equivalent-methods-list.pdf
enveaAF22E
ENVEA AF22E
UV Fluorescence gas monitor offering excellent performances for the monitoring of SO2 in the range 0-10 ppm or 0-1 ppm
Eco-designed, reference air quality monitor, QAL1 certified by the TÜV, US-EPA approved. Utilizes the standard method for the measurement of sulfur dioxides(EN 14212). With its ultra low power consumption & 24 V supply (option), the AF22e is the sole SO2 monitor on the market able to measure without being connected to the power grid.
https://www.envea.global/s/emissions-en/gas-monitors-emissions-en/af22e-dilution/
valid
2022-12-02
2022-12-02
enveaUT3000
ENVEA UT3000
Total Gaseous Mercury (TGM) Ultratracer. Measuring of Total Gaseous Mercury (TGM) in air and other gases
valid
2022-12-02
2022-12-02
enviroAC32E
Environnement S.A. Model AC32E NO2 Analyzer
valid
2022-12-02
2022-12-02
enviroAF20M
Environnement S.A. Model AF20M SO2 Analyzer
valid
2022-12-02
2022-12-02
enviroAF21M
Environnement S.A. Model AF21M SO2 Analyzer
Environnement S.A Model AF21M Sulfur Dioxide Analyzer operated on a range of 0-0.5 ppm with a response time coefficient setting of 01, a Teflon ilter installed in the rear - panel filter assembly, and with or without any of the following options: Rack Mount/Slides; RS-232-C Interface
valid
2022-12-02
2022-12-02
Definition from US EPA
http://www.epa.gov/ttnamti1/files/ambient/criteria/reference-equivalent-methods-list.pdf
enviroAF22M
Environnement S.A. Model AF22M SO2 Analyzer
Environnement S.A Model AF22M UV Fluorescence Sulfur Dioxide Analyzer operated with a full scale range of 0 - 500 ppb, at any temperature in the range of 10°C to 35°C, with a 5-micron PTFE sample particulate filter, with a response time setting of 11 (Automatic response time), with the automatic “ZERO-REF” cycle ON and set for activation every 24 hours, and with or without either of the follow ing options: Permeation oven, Rack mount slides
valid
2022-12-02
2022-12-02
Definition from US EPA
http://www.epa.gov/ttnamti1/files/ambient/criteria/reference-equivalent-methods-list.pdf
enviroAS32M
Environnement S.A. Model AS32M Nitrogen Dioxide Analyzer
valid
2022-12-02
2022-12-02
enviroCO10M
Environnement S.A. Model CO10M CO Analyzer
valid
2022-12-02
2022-12-02
http://www.epa.gov/ttnamti1/files/ambient/criteria/reference-equivalent-methods-list.pdf
enviroCO11M
Environnement S.A. Model CO11M CO Analyzer
Environnement S.A. Model CO11M Ambient Carbon Monoxide Analyzer operated on a full scale range of 0 - 50 ppm, at any temperature in the range of 15 °C to 35°C, with a 5-micron PTFE sample particulate filter, with the following software settings:Automatic response time ON; Minimum response time set to 40 seconds (RT 13); Automatic ZERO-REF cycle programmed every 24 hours; and with or without any of the following options: RS232-422 Serial Interface; Internal Printer
valid
2022-12-02
2022-12-02
Definition from US EPA
http://www.epa.gov/ttnamti1/files/ambient/criteria/reference-equivalent-methods-list.pdf
enviroCO12E
Environnement S.A. Model CO12E CO Analyzer
valid
2022-12-02
2022-12-02
enviroCO12M
Environnement S.A. Model CO12M CO Analyzer
Environnement S.A Model CO12M Gas Filter Correlation Carbon Monoxide Analyzer operated with a full scale range of 0 - 50 ppm, at any temperature in the range of 10°C to 35°C, with a 5-micron PTFE sample particulate filter, with response time ON, and with the automatic “ZERO-REF” cycle either ON or OFF
valid
2022-12-02
2022-12-02
Definition from US EPA
http://www.epa.gov/ttnamti1/files/ambient/criteria/reference-equivalent-methods-list.pdf
enviroHC51M
Environnement-HC51M
Using a proven flame ionisation detector (FID), the analyzer HC51M measures ambient air hydrocarbons (THC, CH4, nmHC) in the range 0-1000 ppm.
valid
2022-12-02
2022-12-02
enviroMP101M
Environnement S.A. Model MP101M (may be used for PM10 and PM2.5)
Environnement S. A. Model MP101M with PM10 or PM2.5 Beta Gauge Monitor,” configured with the louvered PM 10 or PM2.5 inlet specified in 40 CFR 50 Appendix L or its flat-topped predecessor version and one of the three optional temperature-regulated sampling tubes (RST), and operated with a full scale measurement range of 0 - 0.500 mg/m3 (0 - 500 g/m3), with the sample flow rate set to 1.00 m3/h and flow regulation set to yes , the “norms selection” set to m3(actual volume), the “cycle” set to 24 hours, the “period” set to none, and the “counting time” set to 200 seconds
valid
2022-12-02
2022-12-02
Definition from US EPA
http://www.epa.gov/ttnamti1/files/ambient/criteria/reference-equivalent-methods-list.pdf
enviroMP2.5M
Environnement S.A. Model MP2.5M undefined
valid
2022-12-02
2022-12-02
enviroMPSI100
Environnement S.A. Model MPSI 100
valid
2022-12-02
2022-12-02
enviroO331M
enviroO331M
valid
2022-12-02
2022-12-02
enviroO341M
Environnement S.A. Model O341M UV Ozone Analyzer
Environnement S.A. Model O341M UV Photometric Ozone Analyzer operated on a full scale range of 0 - 500 ppb, at any temperature in the range of 15°C to 35°C, with the response time set to 50 seconds, and with or without any of the following options: Internal Ozone Generator; Span External Control; RS232 - 422 Serial Interface; Internal Printer.
valid
2022-12-02
2022-12-02
Definition from US EPA
http://www.epa.gov/ttnamti1/files/ambient/criteria/reference-equivalent-methods-list.pdf
enviroO342E
Environnement S.A. Model O342E UV Ozone Analyzer
valid
2022-12-02
2022-12-02
enviroO342M
Environnement S.A. Model O342M UV Ozone Analyze
Environnement S.A Model O342M UV Photometric Ozone Analyzer,” operated with a full scale range of 0 - 500 ppb, at any temperature in the range of 10°C to 35°C, with a 5-micron PTFE sample particulate filter, with response time setting of 11 (Automatic response time), and with or without any of the following options: c) Internal ozone generator, d) Span external control (zero/span solenoid valve).
valid
2022-12-02
2022-12-02
Definition from US EPA
http://www.epa.gov/ttnamti1/files/ambient/criteria/reference-equivalent-methods-list.pdf
enviroSANOA
Environnement S.A. SANOA Multigas Longpath Monitoring System
Environnement S.A. Model SANOA Multigas Longpath Air Quality Monitoring System consisting of a receiver, one or more projectors, interface unit, a user-provided control unit computer running the SANOA VisionAIR software, and associated incidental equipment; configured for measuring SO2, with the temperature control and internal calibration cell options installed, operated with a measurement range of 0 to 0.5 ppm, over an installed monitoring path length of between 27 and 500 meters, within an ambient air temperature range of -30 to +45°C,with a measurement (integrating) time of 180 seconds, and with or without external temperature and barometric pressure sensors or any of the following options: external (meteo) input connection, series 1M bus connection, OGR type projector, analog outputs.
valid
2022-12-02
2022-12-02
Definition from US EPA
http://www.epa.gov/ttnamti1/files/ambient/criteria/reference-equivalent-methods-list.pdf
horibaAPDA350
Horiba model APDA 350 TSP analyser
valid
2022-12-02
2022-12-02
horibaAPDA350E
Horiba model APDA 350E TSP analyser
valid
2022-12-02
2022-12-02
horibaAPDA351
Horiba model APDA 351 TSP analyser
valid
2022-12-02
2022-12-02
horibaAPDA351E
Horiba model APDA 351E TSP analyser
valid
2022-12-02
2022-12-02
horibaAPDA371
Horiba model APDA 371
valid
2022-12-02
2022-12-02
horibaAPDA372
Horiba model APDA 372
Horiba model APDA 372
valid
2022-12-02
2022-12-02
horibaAPHA350E
Horiba model APHA 360E hydrocarbons analyser
valid
2022-12-02
2022-12-02
horibaAPHA360
Horiba model APHA 360 hydrocarbons analyser
valid
2022-12-02
2022-12-02
horibaAPHA370
Horiba model APHA 370 hydrocarbons analyser
valid
2022-12-02
2022-12-02
horibaAPMA300
Horiba model APMA 300 CO analyser
valid
2022-12-02
2022-12-02
horibaAPMA300E
Horiba model APMA 300E CO analyser
valid
2022-12-02
2022-12-02
horibaAPMA350
Horiba model APMA 350 CO analyser
valid
2022-12-02
2022-12-02
horibaAPMA350E
Horiba model APMA 350E CO analyser
valid
2022-12-02
2022-12-02
horibaAPMA360
Horiba model APMA 360 CO analyser
valid
2022-12-02
2022-12-02
horibaAPMA360CE
Horiba model APMA 360CE CO analyser
valid
2022-12-02
2022-12-02
horibaAPMA360E
Horiba model APMA 360E CO analyser
valid
2022-12-02
2022-12-02
horibaAPMA370
Horiba model APMA 370 CO analyser
valid
2022-12-02
2022-12-02
horibaAPNA300
Horiba model APNA 300 NOx analyser
valid
2022-12-02
2022-12-02
horibaAPNA300E
Horiba model APNA 300E NOx analyser
valid
2022-12-02
2022-12-02
horibaAPNA350
Horiba model APNA 350 NOx analyser
valid
2022-12-02
2022-12-02
horibaAPNA350E
Horiba model APNA 350E NOx analyser
valid
2022-12-02
2022-12-02
horibaAPNA360
Horiba model APNA 360 NOx analyser
valid
2022-12-02
2022-12-02
horibaAPNA360E
Horiba model APNA 360E NOx analyser
valid
2022-12-02
2022-12-02
horibaAPNA370
Horiba model APNA 370 NOx analyser
valid
2022-12-02
2022-12-02
horibaAPOA300
Horiba model APOA 300 O3 analyser
valid
2022-12-02
2022-12-02
horibaAPOA350
Horiba model APOA 350 O3 analyser
valid
2022-12-02
2022-12-02
horibaAPOA350E
Horiba model APOA 350E O3 analyser
valid
2022-12-02
2022-12-02
horibaAPOA360
Horiba model APOA 360 O3 analyser
valid
2022-12-02
2022-12-02
horibaAPOA360E
Horiba model APOA 350E O3 analyser
valid
2022-12-02
2022-12-02
horibaAPOA370
Horiba model APOA 370 O3 analyser
valid
2022-12-02
2022-12-02
horibaAPSA300
Horiba model APSA 300 SO2 analyser
valid
2022-12-02
2022-12-02
horibaAPSA350
Horiba model APSA 350 SO2 analyser
valid
2022-12-02
2022-12-02
horibaAPSA350E
Horiba model APSA 350E SO2 analyser
valid
2022-12-02
2022-12-02
horibaAPSA360
Horiba model APSA 360 SO2 analyser
valid
2022-12-02
2022-12-02
horibaAPSA360A
Horiba model APSA 360A SO2 analyser
valid
2022-12-02
2022-12-02
horibaAPSA360E
Horiba model APSA 360E SO2 analyser
valid
2022-12-02
2022-12-02
horibaAPSA370
Horiba model APSA 370 SO2 analyser
valid
2022-12-02
2022-12-02
horibaFH621R
ONLY USED IN ONE STATION IN RS
valid
2022-12-02
2022-12-02
ONLY USED IN ONE STATION IN RS
http://www.doiserbia.nb.rs/img/doi/1451-9372/2008/1451-93720801005J.pdf
kimoto168s
KIMOTO 168s
valid
2022-12-02
2022-12-02
marga
Marga
valid
2022-12-02
2022-12-02
mcv30ql
MCV 30-QL
valid
2022-12-02
2022-12-02
check pollutant
mcv48auv
MCV 48-AUV
valid
2022-12-02
2022-12-02
check pollutant
mcv64fuv
MCV 64-FUV
valid
2022-12-02
2022-12-02
check pollutant
mcvCAV-AMSb
MCV CAV-A/MSb Captador d'Alt Volum Seqüencial
valid
2022-12-02
2022-12-02
http://www.mcvsa.com/Productes/Atm%C3%B3sfera/CaptadordealtovolumensecuencialMCVCAVAMSb/tabid/139/Default.aspx
mcvCAV-Amb
MCV CAV-A/mb Captador d'Alt Volum
valid
2022-12-02
2022-12-02
http://www.mcvsa.com/Productes/Atm%C3%B3sfera/CaptadordealtovolumenMCVCAVAmb/tabid/114/Default.aspx
meloySA700
Meloy Model SA 700 Fluorescence Sulfur Dioxide Analyze
Meloy Model SA 700 Fluorescence Sulfur Dioxide Analyzeroperated on the 0-250 ppb1, the 0-500 ppb, or the 0-1000 ppb range with a time constant switch position of either 2 or 3.The analyzer may be operated at temperatures between 20°C and 30°C and at line voltages between 105 and 130 volts, with or without any of the following options: FS-1 Current Output; FS-2 Rack Mount Conversion; FS-2A Rack Mount Conversion; FS-2B Rack Mount Conversion; FS-3 Front Panel Mounted Digital Meter; FS-5 Auto/Manual Zero/Span With Status; FS-6
Remote/Manual Zero/Span With Status; FS-7 Auto Zero Adjust.
valid
2022-12-02
2022-12-02
Definition from US EPA
http://www.epa.gov/ttnamti1/files/ambient/criteria/reference-equivalent-methods-list.pdf
multigasMMS
Multi-gas Micro Monitoring station (MMS) Portable version
valid
2022-12-02
2022-12-02
opsisAR500
Opsis AR500 Open path monitor
valid
2022-12-02
2022-12-02
opsisAR500-ER110
Opsis AR500 Open path monitor with ER 110
valid
2022-12-02
2022-12-02
opsisAR500-ER120
Opsis AR500 Open path monitor with ER 120
valid
2022-12-02
2022-12-02
opsisAR500-ER150
Opsis AR500 Open path monitor with ER 150
valid
2022-12-02
2022-12-02
opsisSM200
Opsis SM200 Particulate Analyser with PM2.5 & PM10 Heads
valid
2022-12-02
2022-12-02
osiris
Osiris Turnkey Instruments
Osiris air monitoring device measures airborne particles (TSP, PM10, PM2.5 and PM1). MCERTS certified for PM10
valid
2022-12-02
2022-12-02
other
Other
valid
2022-12-02
2022-12-02
perkinelmerC500
Perkin Elmer Clarus 500
Perkin Elmer Clarus 500
valid
2022-12-02
2022-12-02
perkinelmerTurbomatrixDesorber
Perking Elmer Turbomatrix Desorber
Perking Elmer Turbomatrix Desorber
valid
2022-12-02
2022-12-02
philipsK50031
PHILIPS K50031 Chromatographic Analyser
valid
2022-12-02
2022-12-02
philipsK50033
PHILIPS K50033 API 100E
valid
2022-12-02
2022-12-02
http://fbd.beun.edu.tr/index.php/zkufbd/article/download/53/100
philipsK50034
PHILIPS K50034 API 200A
valid
2022-12-02
2022-12-02
http://fbd.beun.edu.tr/index.php/zkufbd/article/download/53/100
philipsK50093
PHILIPS K50093 API 300A
valid
2022-12-02
2022-12-02
http://fbd.beun.edu.tr/index.php/zkufbd/article/download/53/100
philipsK50094
PHILIPS K50094 API 400
valid
2022-12-02
2022-12-02
http://fbd.beun.edu.tr/index.php/zkufbd/article/download/53/100
philipsK50102
PHILIPS K50102 NO
valid
2022-12-02
2022-12-02
http://www.brace.sinanet.apat.it/
philipsK50109
PHILIPS K50109/00 Gas Filter Correlation CO analyser
valid
2022-12-02
2022-12-02
http://www.docstoc.com/docs/145715957/ABC_EAREX07_instruments
philipsK50110
PHILIPS K50110/00 UV Photometric O3 analyser
valid
2022-12-02
2022-12-02
http://www.docstoc.com/docs/145715957/ABC_EAREX07_instruments
philipsK50129
PHILIPS K50129 unknown
valid
2022-12-02
2022-12-02
check pollutant
philipsK50130
PHILIPS K50130 unknown
valid
2022-12-02
2022-12-02
check pollutant
philipsK50206
PHILIPS K50206/00 Pulsed Fluorescence SO2 analyser
valid
2022-12-02
2022-12-02
http://www.docstoc.com/docs/145715957/ABC_EAREX07_instruments
philipsK50235
PHILIPS K50235/00 NO-NOx-NO2 analyser
valid
2022-12-02
2022-12-02
http://www.arpa.emr.it/cms3/documenti/_cerca_doc/aria/rimini/rn_valloni_tesi_laurea_mar2010.pdf
Philips PW 9700
Philips PW 9700
Philips PW 9700
valid
2022-12-02
2022-12-02
philipsPW9755
PHILIPS PW9755/00 SO2 Analyser
valid
2022-12-02
2022-12-02
philipsPW9762
PHILIPS PW9762/00 NO/NO2/NOX Analyser
valid
2022-12-02
2022-12-02
http://www.epa.gov/ttnamti1/files/ambient/criteria/reference-equivalent-methods-list.pdf
picarroG2103
Picarro G2103
Picarro G2103 (used for NH3 measurement)
valid
2022-12-02
2022-12-02
picarroG2302
Picarro G2302
Picarro G2302 (used for CO measurement)
valid
2022-12-02
2022-12-02
picarroG2303
Picarro G2303
Picarro G2303 (used for CO measurement)
valid
2022-12-02
2022-12-02
serinus40
serinus 40 Nox
valid
2022-12-02
2022-12-02
not from OPSIS
serinus40NH3
serinus 40 with NH3 converter
Ecotech serinus 40 used for NOx-NO2-NO modified to measure NOH3 (including a converter)
valid
2022-12-02
2022-12-02
serinus51
ECOTECH SERINUS 51
The Serinus 51 H2S/SO2 instruments can integrate seamlessly into continuous monitoring networks and can sequentially measure H2S and then SO2
valid
2022-12-02
2022-12-02
sunsetTOCA
EC/OC measurements Sunset Laboratory Inc Thermal / Optical Carbon Analyser (near-real time)
EC/OC measurements Sunset Laboratory Inc Thermal / Optical Carbon Analyser - operated near real time
valid
2022-12-02
2022-12-02
tecanCLD502
Tecan CLD502
valid
2022-12-02
2022-12-02
tekran1130
Tekran mercury analyser 1130
Tekran mercury analyser 1130
valid
2022-12-02
2022-12-02
tekran1135
Tekran mercury analyser 1135
Tekran mercury analyser 1135
valid
2022-12-02
2022-12-02
tekran2537A
Tekran mercury analyser 2537A
Tekran mercury analyser 2537A. Elemental mercury is sampled by placing the 1130 before the main 2537A instrument. The respective constituents are sampled from the air using either the 1130 add-on for reactive gaseous mercury or the 1135 add-on for particulate bound mercury.
valid
2022-12-02
2022-12-02
tekran2537B
Tekran mercury analyser 2537B
Tekran mercury analyser 2537B
valid
2022-12-02
2022-12-02
tekran2537X
Tekran mercury analyser 2537X
Tekran mercury analyser 2537X
valid
2022-12-02
2022-12-02
thermo14B
Thermo model 14B chemiluminescence NO-NO2-Nox
valid
2022-12-02
2022-12-02
thermo14B-E
Thermo model 14B/E chemiluminescence NO-NO2-Nox
valid
2022-12-02
2022-12-02
thermo14BE
Thermo model 14B/E chemiluminescence NO-NO2-Nox
valid
2022-12-02
2022-12-02
thermo42
Thermo model 42 NO/Nox analyser
valid
2022-12-02
2022-12-02
specific model undetermined
check
thermo42c
Thermo model 42c NO/Nox analyser
valid
2022-12-02
2022-12-02
http://www.thermo.com/eThermo/CMA/PDFs/Various/156File_17809.pdf
thermo42c-TL
Thermo model 42C-TL (Trace level Nox)
valid
2022-12-02
2022-12-02
does this exist?
https://www.thermo.com/eThermo/CMA/PDFs/Product/productPDF_20985.pdf
thermo42i
Thermo model 42i NO/Nox analyser
valid
2022-12-02
2022-12-02
thermo42i-BL
Thermo model 42i NO/NOx analyser - blue light
valid
2022-12-02
2022-12-02
thermo42i-TL
Thermo model 42i-TL (Trace level Nox)
valid
2022-12-02
2022-12-02
https://www.thermo.com/eThermo/CMA/PDFs/Product/productPDF_30698.pdf
thermo42s
Thermo model 42s NO/Nox analyser
valid
2022-12-02
2022-12-02
thermo42w
Thermo model 42w NO/Nox analyser
valid
2022-12-02
2022-12-02
thermo43
Thermo model 43 SO2 analyser
valid
2022-12-02
2022-12-02
specific model undetermined
thermo43CTL
Thermo model 43c-TL SO2 analyser
valid
2022-12-02
2022-12-02
https://www.thermo.com/eThermo/CMA/PDFs/Product/productPDF_30540.pdf
thermo43a
Thermo model 43a SO2 analyser
valid
2022-12-02
2022-12-02
thermo43b
Thermo model 43b SO2 analyser
valid
2022-12-02
2022-12-02
thermo43bs
Thermo model 43bs SO2 analyser
valid
2022-12-02
2022-12-02
thermo43c
Thermo model 43c SO2 analyser
valid
2022-12-02
2022-12-02
thermo43h
Thermo model 43h pulsed fluorescence SO2 analyser
valid
2022-12-02
2022-12-02
thermo43i
Thermo model 43i SO2 analyser
valid
2022-12-02
2022-12-02
https://static.thermoscientific.com/images/D19736~.pdf
thermo43i-TLE
Thermo model 43i-TLE (Enhanced Trace Level)
valid
2022-12-02
2022-12-02
http://www.thermo.com/eThermo/CMA/PDFs/Product/productPDF_20982.pdf
thermo43s
Thermo model 43s SO2 analyser
valid
2022-12-02
2022-12-02
check
thermo43w
Thermo model 43w SO2 analyser
valid
2022-12-02
2022-12-02
thermo48
Thermo model 48 CO analyser
valid
2022-12-02
2022-12-02
thermo48-GFC
Thermo model 48 CO analyser (gas filter correlation)
valid
2022-12-02
2022-12-02
thermo48c
Thermo model 48c CO analyser
valid
2022-12-02
2022-12-02
thermo48i
Thermo model 48i CO analyser
valid
2022-12-02
2022-12-02
thermo48i-TLE
Thermo model 48i-TLE (Enhanced Trace Level)
valid
2022-12-02
2022-12-02
thermo48w
Thermo model 48w CO analyser
valid
2022-12-02
2022-12-02
thermo49
Thermo model 49 O3 analyser
valid
2022-12-02
2022-12-02
thermo49c
Thermo model 49c O3 analyser
valid
2022-12-02
2022-12-02
thermo49cps
Thermo 49 CPS Ozone Primary Standard
valid
2022-12-02
2022-12-02
Thermo 49 CPS Ozone Primary Standard
This is a reference photomer, not an analyser
http://rental.cleanair.com/thermo49cpsozoneprimarystandard
thermo49i
Thermo model 49i O3 analyser
valid
2022-12-02
2022-12-02
thermo49w
Thermo model 49w O3 analyser
valid
2022-12-02
2022-12-02
thermo5012MAAP
Thermo Scientific 5012 MAAP
The Model 5012 MAAP measures the aerosol-related absorption of light and the corresponding atmospheric black carbon mass concentration. Continuous data is provided by a multiple detector setup to simultaneously measure the transmitted and the scattered light from a particle-loaded filter. Typical applications include determining ambient elemental carbon for health-related effects and aerosol light absorption for visibility monitoring (regional haze) and climate research.
valid
2022-12-02
2022-12-02
thermo5014i
Thermo 5014i Beta Continuous Ambient Particulate Monitor
Measure PM-10, PM-2.5 or PM-1 mass concentrations with the Thermo Scientific™ 5014i Beta Continuous Ambient Particulate Monitor. The 5014i distinguishes itself from other beta measurement methods by utilizing a continuous (non-step wise) mass measurement with a proven industry standard which provides for long-term unattended operation. To accurately address potential water bias and volatile loss, the Dynamic Heating System allows the user to hold the sample temperature at a fixed value or below a relative humidity threshold.
valid
2022-12-02
2022-12-02
thermo5030SHARP
Thermo model 5030 SHARP Particular Monitor with PM10 & PM2.5 heads
The Thermo Scientific™ 5030 SHARP continuously measures the mass concentration of particulate utilizing a combination of beta attenuation and light scattering technology.
The only continuous (non-step wise) hybrid ambient monitor that provides high resolution measurement of airborne particulates with excellent short and long term precision.
valid
2022-12-02
2022-12-02
thermoAorC
Thermo a or c-series
valid
2022-12-02
2022-12-02
thermoI
Thermo i-series
valid
2022-12-02
2022-12-02
undetermined
too generic
valid
2022-12-02
2022-12-02
too generic
unknown
Unknown
valid
2022-12-02
2022-12-02
unor610
UNOR 610 (5) - SICK
UNOR 610 (5) - SICK
valid
2022-12-02
2022-12-02
unor6N
Maihak Unor 6N
valid
2022-12-02
2022-12-02
check pollutant
varian3800
Varian 3800
Varian 3800
valid
2022-12-02
2022-12-02