{
  "@context" : {
    "@base" : "http://dd.eionet.europa.eu/vocabulary/aq/measurementequipment/",
    "skos" : "http://www.w3.org/2004/02/skos/core#",
    "concepts" : "skos:Concept",
    "prefLabel" : "skos:prefLabel",
    "broader" : "skos:broader",
    "narrower" : "skos:narrower",
    "@language" : "en",
    "VocabularyId" : "233",
    "ContinuityId" : "aeeecec9-d756-3b8e-beaa-eb00931dfa82",
    "Identifier" : "measurementequipment",
    "Label" : "AQD - Measurement Equipment**",
    "RegistrationStatus" : "Released",
    "IsWorkingCopy" : "false",
    "CheckedOutCopyId" : "0",
    "WorkingUser" : null,
    "DateModified" : "2025-11-26 09:16:16.0",
    "UserModified" : "colinmar",
    "IsNumericConceptIdentifiers" : "false",
    "VocabularyType" : "Common",
    "FolderId" : "1",
    "FolderName" : "aq",
    "FolderLabel" : "Air Quality Directive e-Reporting",
    "IsNotationsEqualIdentifiers" : "false",
    "Definition" : "AQD Decision 2011/850/EU - Measurement Equipment - used when measurement type is AUTOMATIC. Broader description provided within MeasurementMethod.",
    "Version" : "0.1"
  },
  "concepts" : [ {
    "@id" : "AE22-PM2.5",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "AE22 Aethalometer with PM2.5 cyclone",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729474",
    "VocabularyId" : "233",
    "Identifier" : "AE22-PM2.5",
    "Label" : "AE22 Aethalometer with PM2.5 cyclone",
    "Definition" : null,
    "Notation" : "AE22-PM2.5",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/391" ]
  }, {
    "@id" : "AE31",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "AE31 Aethalometer",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729475",
    "VocabularyId" : "233",
    "Identifier" : "AE31",
    "Label" : "AE31 Aethalometer",
    "Definition" : null,
    "Notation" : "AE31",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/391" ]
  }, {
    "@id" : "AE33",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "AE33 Aethalometer",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729476",
    "VocabularyId" : "233",
    "Identifier" : "AE33",
    "Label" : "AE33 Aethalometer",
    "Definition" : null,
    "Notation" : "AE33",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/391" ]
  }, {
    "@id" : "AE33-PM2.5",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "AE33 Aethalometer with PM2.5 cyclone",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729477",
    "VocabularyId" : "233",
    "Identifier" : "AE33-PM2.5",
    "Label" : "AE33 Aethalometer with PM2.5 cyclone",
    "Definition" : "AE33 Aethalometer with PM2.5 cyclone",
    "Notation" : "AE33-PM2.5",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/391" ]
  }, {
    "@id" : "AE36",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "AE36 Aethalometer",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729478",
    "VocabularyId" : "233",
    "Identifier" : "AE36",
    "Label" : "AE36 Aethalometer",
    "Definition" : "AE36 Aethalometer",
    "Notation" : "AE36",
    "Status" : "Valid",
    "StatusModifiedDate" : "2025-04-21",
    "AcceptedDate" : "2025-04-21",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/391" ]
  }, {
    "@id" : "AIRTOXICA73022",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Chromatotec AirTOXIC BTX PID - A73022",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729479",
    "VocabularyId" : "233",
    "Identifier" : "AIRTOXICA73022",
    "Label" : "Chromatotec AirTOXIC BTX PID - A73022",
    "Definition" : "Using gas chromatography: the model airTOXIC BTX PID measures the amount of Benzene Toluene Ethylbenzene and Xylenes in the air from sub-ppb levels up to 1.000 ppb.",
    "Notation" : "AIRTOXICA73022",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/431", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/20", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/21", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/464", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/80", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/482", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/81" ]
  }, {
    "@id" : "AL5001",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "AEROLaser 5001 CO Analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729480",
    "VocabularyId" : "233",
    "Identifier" : "AL5001",
    "Label" : "AEROLaser 5001 CO Analyser",
    "Definition" : "AEROLaser 5001 CO Analyser",
    "Notation" : "AL5001",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-23",
    "AcceptedDate" : "2024-08-23",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "ANNOX",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "ANNOX",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729481",
    "VocabularyId" : "233",
    "Identifier" : "ANNOX",
    "Label" : "ANNOX",
    "Definition" : null,
    "Notation" : "ANNOX",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "API",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Teledyne API undertermined",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729482",
    "VocabularyId" : "233",
    "Identifier" : "API",
    "Label" : "Teledyne API undertermined",
    "Definition" : null,
    "Notation" : "API",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "API100",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Teledyne API 100 UV Fluorescent SO2 Analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729483",
    "VocabularyId" : "233",
    "Identifier" : "API100",
    "Label" : "Teledyne API 100 UV Fluorescent SO2 Analyser",
    "Definition" : null,
    "Notation" : "API100",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "API100A",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Teledyne API 100A UV Fluorescent SO2 Analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729484",
    "VocabularyId" : "233",
    "Identifier" : "API100A",
    "Label" : "Teledyne API 100A UV Fluorescent SO2 Analyser",
    "Definition" : null,
    "Notation" : "API100A",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "API100E",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Teledyne API 100E UV Fluorescent SO2 Analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729485",
    "VocabularyId" : "233",
    "Identifier" : "API100E",
    "Label" : "Teledyne API 100E UV Fluorescent SO2 Analyser",
    "Definition" : null,
    "Notation" : "API100E",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "API101",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Teledyne API 101 UV Fluorescent SO2 Analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729486",
    "VocabularyId" : "233",
    "Identifier" : "API101",
    "Label" : "Teledyne API 101 UV Fluorescent SO2 Analyser",
    "Definition" : null,
    "Notation" : "API101",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "API101A",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Teledyne API 101A UV Fluorescent SO2/H2S Analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729487",
    "VocabularyId" : "233",
    "Identifier" : "API101A",
    "Label" : "Teledyne API 101A UV Fluorescent SO2/H2S Analyser",
    "Definition" : null,
    "Notation" : "API101A",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/11" ]
  }, {
    "@id" : "API200",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Teledyne API 200 chemiluminescent NOx analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729488",
    "VocabularyId" : "233",
    "Identifier" : "API200",
    "Label" : "Teledyne API 200 chemiluminescent NOx analyser",
    "Definition" : null,
    "Notation" : "API200",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38" ]
  }, {
    "@id" : "API200A",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Teledyne API 200A chemiluminescent NOx analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729489",
    "VocabularyId" : "233",
    "Identifier" : "API200A",
    "Label" : "Teledyne API 200A chemiluminescent NOx analyser",
    "Definition" : null,
    "Notation" : "API200A",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38" ]
  }, {
    "@id" : "API200AU",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "TELEDYNE API 200AU",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729490",
    "VocabularyId" : "233",
    "Identifier" : "API200AU",
    "Label" : "TELEDYNE API 200AU",
    "Definition" : "Teledyne API 200AU chemiluminescent NOx analyser",
    "Notation" : "API200AU",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9" ]
  }, {
    "@id" : "API200E",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Teledyne API 200E chemiluminescent NOx analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729491",
    "VocabularyId" : "233",
    "Identifier" : "API200E",
    "Label" : "Teledyne API 200E chemiluminescent NOx analyser",
    "Definition" : null,
    "Notation" : "API200E",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38" ]
  }, {
    "@id" : "API200EU",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Teledyne API 200EU chemiluminescent NOx analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729492",
    "VocabularyId" : "233",
    "Identifier" : "API200EU",
    "Label" : "Teledyne API 200EU chemiluminescent NOx analyser",
    "Definition" : null,
    "Notation" : "API200EU",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38" ]
  }, {
    "@id" : "API200EU-BL",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Teledyne API 200EU chemiluminescent NOx analyser - blue light",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729493",
    "VocabularyId" : "233",
    "Identifier" : "API200EU-BL",
    "Label" : "Teledyne API 200EU chemiluminescent NOx analyser - blue light",
    "Definition" : null,
    "Notation" : "API200EU-BL",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8" ]
  }, {
    "@id" : "API200UP",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Teledyne API 200UP chemiluminescent NOx analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729494",
    "VocabularyId" : "233",
    "Identifier" : "API200UP",
    "Label" : "Teledyne API 200UP chemiluminescent NOx analyser",
    "Definition" : null,
    "Notation" : "API200UP",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9" ]
  }, {
    "@id" : "API201A",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Teledyne API 200A chemiluminescent NOx analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729495",
    "VocabularyId" : "233",
    "Identifier" : "API201A",
    "Label" : "Teledyne API 200A chemiluminescent NOx analyser",
    "Definition" : null,
    "Notation" : "API201A",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38" ]
  }, {
    "@id" : "API300",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Teledyne API 300 gas filter correlation CO analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729496",
    "VocabularyId" : "233",
    "Identifier" : "API300",
    "Label" : "Teledyne API 300 gas filter correlation CO analyser",
    "Definition" : null,
    "Notation" : "API300",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "API300A",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Teledyne API 300A gas filter correlation CO analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729497",
    "VocabularyId" : "233",
    "Identifier" : "API300A",
    "Label" : "Teledyne API 300A gas filter correlation CO analyser",
    "Definition" : null,
    "Notation" : "API300A",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "API300E",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Teledyne API 300E gas filter correlation CO analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729498",
    "VocabularyId" : "233",
    "Identifier" : "API300E",
    "Label" : "Teledyne API 300E gas filter correlation CO analyser",
    "Definition" : null,
    "Notation" : "API300E",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "API400",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Teledyne API 400 UV photometric O3 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729499",
    "VocabularyId" : "233",
    "Identifier" : "API400",
    "Label" : "Teledyne API 400 UV photometric O3 analyser",
    "Definition" : null,
    "Notation" : "API400",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "API400A",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Teledyne API 400A UV photometric O3 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729500",
    "VocabularyId" : "233",
    "Identifier" : "API400A",
    "Label" : "Teledyne API 400A UV photometric O3 analyser",
    "Definition" : null,
    "Notation" : "API400A",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "API400E",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Teledyne API 400E UV photometric O3 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729501",
    "VocabularyId" : "233",
    "Identifier" : "API400E",
    "Label" : "Teledyne API 400E UV photometric O3 analyser",
    "Definition" : null,
    "Notation" : "API400E",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "APIM100E",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Teledyne API M100E UV Fluorescent SO2 Analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729502",
    "VocabularyId" : "233",
    "Identifier" : "APIM100E",
    "Label" : "Teledyne API M100E UV Fluorescent SO2 Analyser",
    "Definition" : null,
    "Notation" : "APIM100E",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "APIM200E",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Teledyne API M200E chemiluminescent NOx analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729503",
    "VocabularyId" : "233",
    "Identifier" : "APIM200E",
    "Label" : "Teledyne API M200E chemiluminescent NOx analyser",
    "Definition" : null,
    "Notation" : "APIM200E",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38" ]
  }, {
    "@id" : "APIM300E",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Teledyne API M300E gas filter correlation CO analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729504",
    "VocabularyId" : "233",
    "Identifier" : "APIM300E",
    "Label" : "Teledyne API M300E gas filter correlation CO analyser",
    "Definition" : null,
    "Notation" : "APIM300E",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "APIM400E",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Teledyne API M400E UV photometric O3 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729505",
    "VocabularyId" : "233",
    "Identifier" : "APIM400E",
    "Label" : "Teledyne API M400E UV photometric O3 analyser",
    "Definition" : null,
    "Notation" : "APIM400E",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "APIT100",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Teledyne API T100 UV Fluorescent SO2 Analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729506",
    "VocabularyId" : "233",
    "Identifier" : "APIT100",
    "Label" : "Teledyne API T100 UV Fluorescent SO2 Analyser",
    "Definition" : null,
    "Notation" : "APIT100",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "APIT100U",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Teledyne API T100U UV Fluorescent SO2 Analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729507",
    "VocabularyId" : "233",
    "Identifier" : "APIT100U",
    "Label" : "Teledyne API T100U UV Fluorescent SO2 Analyser",
    "Definition" : null,
    "Notation" : "APIT100U",
    "Status" : "Valid",
    "StatusModifiedDate" : "2025-11-25",
    "AcceptedDate" : "2025-11-25",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "APIT200",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Teledyne API T200 chemiluminescent NOx analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729508",
    "VocabularyId" : "233",
    "Identifier" : "APIT200",
    "Label" : "Teledyne API T200 chemiluminescent NOx analyser",
    "Definition" : null,
    "Notation" : "APIT200",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9" ]
  }, {
    "@id" : "APIT200U",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Teledyne API T200U chemiluminescent NOx analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729509",
    "VocabularyId" : "233",
    "Identifier" : "APIT200U",
    "Label" : "Teledyne API T200U chemiluminescent NOx analyser",
    "Definition" : "he Model T200U Trace-level NO/NO2/NOx analyzer has been developed specifically to address the challenges of low-level monitoring as required in the US NCore network. It uses the proven chemiluminescence principle and is designed to allow ultra-sensitive measurements with a lower detectable limit of 50 ppt while still meeting the requirements for use as a US EPA compliance analyzer.The Model T200U combines a gold plated reaction cell with an enhanced performance pump special low noise photomultiplier tube and unique signal conditioning to provide exceptional sensitivity. In addition a pre-reactor separates the NO-O3 reaction from background chemiluminescence to allow accurate auto-zero of the analyzer.All T Series instruments offer an advanced color display capacitive touch screen intuitive user interface flexible I/O and built-in data acquisition capability. All instrument set up control and access to stored data and diagnostic information is available through the front panel or via RS232 Ethernet or USB com ports either locally or by remote connection.The Model T200U comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.e allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.",
    "Notation" : "APIT200U",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8" ]
  }, {
    "@id" : "APIT300",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Teledyne API T300 gas filter correlation CO analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729510",
    "VocabularyId" : "233",
    "Identifier" : "APIT300",
    "Label" : "Teledyne API T300 gas filter correlation CO analyser",
    "Definition" : null,
    "Notation" : "APIT300",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "APIT400",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Teledyne API T400 UV photometric O3 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729511",
    "VocabularyId" : "233",
    "Identifier" : "APIT400",
    "Label" : "Teledyne API T400 UV photometric O3 analyser",
    "Definition" : null,
    "Notation" : "APIT400",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "APIT500U",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Teledyne API T500U CAPS NO2 Analyzer",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729512",
    "VocabularyId" : "233",
    "Identifier" : "APIT500U",
    "Label" : "Teledyne API T500U CAPS NO2 Analyzer",
    "Definition" : null,
    "Notation" : "APIT500U",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-23",
    "AcceptedDate" : "2024-08-23",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38" ]
  }, {
    "@id" : "AirmoBTX_GC866",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "AirmoBTX_GC866",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729513",
    "VocabularyId" : "233",
    "Identifier" : "AirmoBTX_GC866",
    "Label" : "AirmoBTX_GC866",
    "Definition" : "The airmoVOC BTX is a gas chromatograph for the analysis and monitoring of trace amounts of benzene, toluene, ethylbenzene (m/p/o) xylene by FID detection.",
    "Notation" : "AirmoBTX_GC866",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-12-12",
    "AcceptedDate" : "2024-12-12",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/431", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/482", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/20", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/21", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/464" ]
  }, {
    "@id" : "BAM1020",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "MetOne BAM-1020",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729514",
    "VocabularyId" : "233",
    "Identifier" : "BAM1020",
    "Label" : "MetOne BAM-1020",
    "Definition" : null,
    "Notation" : "BAM1020",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001" ]
  }, {
    "@id" : "BAM1020heated",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "MetOne BAM-1020 heated",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729515",
    "VocabularyId" : "233",
    "Identifier" : "BAM1020heated",
    "Label" : "MetOne BAM-1020 heated",
    "Definition" : null,
    "Notation" : "BAM1020heated",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001" ]
  }, {
    "@id" : "BAM1020unheated",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "MetOne BAM-1020 unheated",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729516",
    "VocabularyId" : "233",
    "Identifier" : "BAM1020unheated",
    "Label" : "MetOne BAM-1020 unheated",
    "Definition" : null,
    "Notation" : "BAM1020unheated",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5" ]
  }, {
    "@id" : "COM_DER_APM2",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "COMDE DERENDA APM-2",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729517",
    "VocabularyId" : "233",
    "Identifier" : "COM_DER_APM2",
    "Label" : "COMDE DERENDA APM-2",
    "Definition" : "The method applied by the APM-2 uses the light scattered by tiny particles (nephelometry) to determine the PM10 or PM2.5 concentration in the ambient air directly and continuously.",
    "Notation" : "COM_DER_APM2",
    "Status" : "Valid",
    "StatusModifiedDate" : "2025-07-29",
    "AcceptedDate" : "2025-07-29",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001" ]
  }, {
    "@id" : "COmonitorEurope",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "CO Monitor Europe",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729518",
    "VocabularyId" : "233",
    "Identifier" : "COmonitorEurope",
    "Label" : "CO Monitor Europe",
    "Definition" : "CO Monitor Europe",
    "Notation" : "COmonitorEurope",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "CP7001-BTX",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Chrompack   BTX  CP7001 Monitor",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729519",
    "VocabularyId" : "233",
    "Identifier" : "CP7001-BTX",
    "Label" : "Chrompack   BTX  CP7001 Monitor",
    "Definition" : null,
    "Notation" : "CP7001-BTX",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ "other BTX" ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/20" ]
  }, {
    "@id" : "DELTA",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "DELTA",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729520",
    "VocabularyId" : "233",
    "Identifier" : "DELTA",
    "Label" : "DELTA",
    "Definition" : null,
    "Notation" : "DELTA",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "DHA80-Digitel",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "High Volume Aerosol Sampler DHA-80",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729521",
    "VocabularyId" : "233",
    "Identifier" : "DHA80-Digitel",
    "Label" : "High Volume Aerosol Sampler DHA-80",
    "Definition" : "DIGITEL High Volume Samplers DHA-80 are fully automatic systems to sample dust and aerosol particles for later assessment and analysis (gravimetric and analytical determination). The sampler operation range in standard execution is 100 to 1’500 litres per minute (6 to 90 m³/h).",
    "Notation" : "DHA80-Digitel",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-23",
    "AcceptedDate" : "2024-08-23",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5" ]
  }, {
    "@id" : "DKK-TOA_Gu-X-113E",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "DKK-TOA_Gu-X-113E",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729522",
    "VocabularyId" : "233",
    "Identifier" : "DKK-TOA_Gu-X-113E",
    "Label" : "DKK-TOA_Gu-X-113E",
    "Definition" : "This instrument provides continuous and reliable measurement of Ozone in ambient air. Measurement is based on the UV photometric method as specified in ISO-13964",
    "Notation" : "DKK-TOA_Gu-X-113E",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "DPA14-Digitel",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Low Volume Aerosol Sampler DPA-14",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729523",
    "VocabularyId" : "233",
    "Identifier" : "DPA14-Digitel",
    "Label" : "Low Volume Aerosol Sampler DPA-14",
    "Definition" : "DIGITEL Low Volume Samplers DPA-14 are fully automatic systems to sample dust and aerosol particles for later assessment and analysis (gravimetric and analytical determination) in accordance with EN12341:2023",
    "Notation" : "DPA14-Digitel",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-23",
    "AcceptedDate" : "2024-08-23",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5" ]
  }, {
    "@id" : "Dasibi1003AH",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Dasibi 1003-AH Air Water Ozone Concentration PPM Measurement Analyzer Monitor",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729524",
    "VocabularyId" : "233",
    "Identifier" : "Dasibi1003AH",
    "Label" : "Dasibi 1003-AH Air Water Ozone Concentration PPM Measurement Analyzer Monitor",
    "Definition" : null,
    "Notation" : "Dasibi1003AH",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-23",
    "AcceptedDate" : "2024-08-23",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "Dasibi2110A",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Dasibi 2110A",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729525",
    "VocabularyId" : "233",
    "Identifier" : "Dasibi2110A",
    "Label" : "Dasibi 2110A",
    "Definition" : "For measuring NO NO2 and NOx",
    "Notation" : "Dasibi2110A",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9" ]
  }, {
    "@id" : "EC9852",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "ECOTECH EC9852",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729526",
    "VocabularyId" : "233",
    "Identifier" : "EC9852",
    "Label" : "ECOTECH EC9852",
    "Definition" : "The EC9852 Sulfur Compounds Analyzer combines microprocessor control with fluorescence detection and an external converter to measure H2S and SO2 or TS TRS and SO2 or H2S SO2 and H2S + SO2 in the range of 0-2 ppm with a detection limit of 0.5 ppb for SO2.",
    "Notation" : "EC9852",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "Ecophysics-CLD700AL",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Eco Physics CLD 700 AL",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729527",
    "VocabularyId" : "233",
    "Identifier" : "Ecophysics-CLD700AL",
    "Label" : "Eco Physics CLD 700 AL",
    "Definition" : null,
    "Notation" : "Ecophysics-CLD700AL",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8" ]
  }, {
    "@id" : "Ecophysics-CLD780TR",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Eco Physics CLD 780 TR",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729528",
    "VocabularyId" : "233",
    "Identifier" : "Ecophysics-CLD780TR",
    "Label" : "Eco Physics CLD 780 TR",
    "Definition" : null,
    "Notation" : "Ecophysics-CLD780TR",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9" ]
  }, {
    "@id" : "EnveaAC32e",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Envea AC32e - NO/NO2/NOx Analyzer (replaces enviroAC32E)",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729529",
    "VocabularyId" : "233",
    "Identifier" : "EnveaAC32e",
    "Label" : "Envea AC32e - NO/NO2/NOx Analyzer (replaces enviroAC32E)",
    "Definition" : null,
    "Notation" : "EnveaAC32e",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-23",
    "AcceptedDate" : "2024-08-23",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8" ]
  }, {
    "@id" : "EnveaMP101M",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "MP101M particulate analyzer (replaces enviroMP101M)",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729530",
    "VocabularyId" : "233",
    "Identifier" : "EnveaMP101M",
    "Label" : "MP101M particulate analyzer (replaces enviroMP101M)",
    "Definition" : null,
    "Notation" : "EnveaMP101M",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-23",
    "AcceptedDate" : "2024-08-23",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001" ]
  }, {
    "@id" : "EnveaO342e",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Envea O342e - UV Photometric Ozone Analyzer (replaces enviroO342E)",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729531",
    "VocabularyId" : "233",
    "Identifier" : "EnveaO342e",
    "Label" : "Envea O342e - UV Photometric Ozone Analyzer (replaces enviroO342E)",
    "Definition" : null,
    "Notation" : "EnveaO342e",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-23",
    "AcceptedDate" : "2024-08-23",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "Enviro1003RS",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Environnement S.A. Model 1003-RS O3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729532",
    "VocabularyId" : "233",
    "Identifier" : "Enviro1003RS",
    "Label" : "Environnement S.A. Model 1003-RS O3",
    "Definition" : "Environnement S.A. Model 1003-RS under DASIBI license",
    "Notation" : "Enviro1003RS",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "Environnement_SF8",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Environnement SF8",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729533",
    "VocabularyId" : "233",
    "Identifier" : "Environnement_SF8",
    "Label" : "Environnement SF8",
    "Definition" : "Environnement SF8 for black smoke and acidity",
    "Notation" : "Environnement_SF8",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "F-701-20",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "F-701-20 Verewa / Durag",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729534",
    "VocabularyId" : "233",
    "Identifier" : "F-701-20",
    "Label" : "F-701-20 Verewa / Durag",
    "Definition" : "Ambient Air Dust Concentration Monitor",
    "Notation" : "F-701-20",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6002", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001" ]
  }, {
    "@id" : "FIDAS100",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Palas model FIDAS 100",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729535",
    "VocabularyId" : "233",
    "Identifier" : "FIDAS100",
    "Label" : "Palas model FIDAS 100",
    "Definition" : null,
    "Notation" : "FIDAS100",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-12-13",
    "AcceptedDate" : "2024-12-13",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5" ]
  }, {
    "@id" : "FIDAS100E",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Palas model FIDAS 100E",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729536",
    "VocabularyId" : "233",
    "Identifier" : "FIDAS100E",
    "Label" : "Palas model FIDAS 100E",
    "Definition" : null,
    "Notation" : "FIDAS100E",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-12-13",
    "AcceptedDate" : "2024-12-13",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5" ]
  }, {
    "@id" : "FIDAS200",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Palas model FIDAS 200",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729537",
    "VocabularyId" : "233",
    "Identifier" : "FIDAS200",
    "Label" : "Palas model FIDAS 200",
    "Definition" : null,
    "Notation" : "FIDAS200",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6002", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/4" ]
  }, {
    "@id" : "FIDAS200E",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Palas model FIDAS 200E",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729538",
    "VocabularyId" : "233",
    "Identifier" : "FIDAS200E",
    "Label" : "Palas model FIDAS 200E",
    "Definition" : null,
    "Notation" : "FIDAS200E",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/4", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6002", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001" ]
  }, {
    "@id" : "FIDAS200S",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Palas model FIDAS 200S",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729539",
    "VocabularyId" : "233",
    "Identifier" : "FIDAS200S",
    "Label" : "Palas model FIDAS 200S",
    "Definition" : null,
    "Notation" : "FIDAS200S",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6002", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/4" ]
  }, {
    "@id" : "GC5000BTX-FID",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "AMA GC5000 BTX Type FID",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729540",
    "VocabularyId" : "233",
    "Identifier" : "GC5000BTX-FID",
    "Label" : "AMA GC5000 BTX Type FID",
    "Definition" : null,
    "Notation" : "GC5000BTX-FID",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/21", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/20" ]
  }, {
    "@id" : "GC5000BTX-PID",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "AMA GC5000 BTX Type PID",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729541",
    "VocabularyId" : "233",
    "Identifier" : "GC5000BTX-PID",
    "Label" : "AMA GC5000 BTX Type PID",
    "Definition" : null,
    "Notation" : "GC5000BTX-PID",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ "other BTX" ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/20" ]
  }, {
    "@id" : "GC855BTX",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "SINTECH SPECTRAS BTX GC 855 series undetermined",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729542",
    "VocabularyId" : "233",
    "Identifier" : "GC855BTX",
    "Label" : "SINTECH SPECTRAS BTX GC 855 series undetermined",
    "Definition" : null,
    "Notation" : "GC855BTX",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ "http://www.synspec.nl/docs/manuals/manual-3-Manual%20operator%20Syntech%20Spectras%20GC955%20600-800.pdf" ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/482", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/431", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/21", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/464", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/20" ]
  }, {
    "@id" : "GC855BTX-600",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "SINTECH SPECTRAS BTX GC 855 serie 600",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729543",
    "VocabularyId" : "233",
    "Identifier" : "GC855BTX-600",
    "Label" : "SINTECH SPECTRAS BTX GC 855 serie 600",
    "Definition" : null,
    "Notation" : "GC855BTX-600",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ "other BTX" ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/20" ]
  }, {
    "@id" : "GC866",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Chromatotec GC866",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729544",
    "VocabularyId" : "233",
    "Identifier" : "GC866",
    "Label" : "Chromatotec GC866",
    "Definition" : "Analysis of VOC/BTEX in ambient air at very low concentration levels (ppb/ppt) thanks to precontration using a trap",
    "Notation" : "GC866",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ "BTEX/VOC" ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/482", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/80", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/20", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/21", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/33", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/431" ]
  }, {
    "@id" : "GC955",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "SYNTECH SPECTRAS GC 955 series undetermined",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729545",
    "VocabularyId" : "233",
    "Identifier" : "GC955",
    "Label" : "SYNTECH SPECTRAS GC 955 series undetermined",
    "Definition" : null,
    "Notation" : "GC955",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ "http://www.synspec.nl/docs/manuals/manual-3-Manual%20operator%20Syntech%20Spectras%20GC955%20600-800.pdf" ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/464", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/432", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6011", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6006", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/443", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/503", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6012", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/451", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/475", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/24", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/20", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6008", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/430", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/447", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6013", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/441", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6009", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/316", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6005", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/486", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/450", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6007", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/21", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/428", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/431", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/449", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/394", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/505", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/482" ]
  }, {
    "@id" : "GC955-600",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "SYNTECH SPECTRAS GC 955-600",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729546",
    "VocabularyId" : "233",
    "Identifier" : "GC955-600",
    "Label" : "SYNTECH SPECTRAS GC 955-600",
    "Definition" : null,
    "Notation" : "GC955-600",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ "http://www.synspec.nl/docs/manuals/manual-3-Manual%20operator%20Syntech%20Spectras%20GC955%20600-800.pdf" ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/464", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/21", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/482", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/20", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/431" ]
  }, {
    "@id" : "GC955-601",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "SYNTECH SPECTRAS GC 955-601",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729547",
    "VocabularyId" : "233",
    "Identifier" : "GC955-601",
    "Label" : "SYNTECH SPECTRAS GC 955-601",
    "Definition" : "Gas chromatograph (GC) specifically built for the measurement of BTEX in ambient air. It can be utilised to simultaneously detect and measure up to 40 different components",
    "Notation" : "GC 955-601",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/431", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/21", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/33", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/80", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/20", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/482" ]
  }, {
    "@id" : "GC955-615_815",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "SYNTECH SPECTRAS GC 955-615/815",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729548",
    "VocabularyId" : "233",
    "Identifier" : "GC955-615_815",
    "Label" : "SYNTECH SPECTRAS GC 955-615/815",
    "Definition" : "SYNSPEC GC955 615/815 Ozone Precursor Analyzer",
    "Notation" : "GC955-615_815",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-12-03",
    "AcceptedDate" : "2024-12-03",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/431", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/428", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6008", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/475", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/443", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/394", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6009", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6012", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/447", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6005", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/505", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6007", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/432", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/450", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/464", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6011", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/21", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/430", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/486", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/24", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/451", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/20", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/482", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/441", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6013", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6006", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/503", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/449", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/316" ]
  }, {
    "@id" : "GC955-800",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "SYNTECH SPECTRAS GC 955-800",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729549",
    "VocabularyId" : "233",
    "Identifier" : "GC955-800",
    "Label" : "SYNTECH SPECTRAS GC 955-800",
    "Definition" : null,
    "Notation" : "GC955-800",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ "http://www.synspec.nl/docs/manuals/manual-3-Manual%20operator%20Syntech%20Spectras%20GC955%20600-800.pdf" ],
    "skos:relatedMatch" : [ "other VOC" ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/20" ]
  }, {
    "@id" : "GRIMM-CPC5412",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "GRIMM CPC model 5412 Standard Condensation Particle Counter",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729550",
    "VocabularyId" : "233",
    "Identifier" : "GRIMM-CPC5412",
    "Label" : "GRIMM CPC model 5412 Standard Condensation Particle Counter",
    "Definition" : "Compact CPC for nanoparticle counting with optimized detection efficiency and response time with integrated sample flow pump.  Different calibrations possible",
    "Notation" : "GRIMM-CPC5412",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6003" ]
  }, {
    "@id" : "GRIMM-CPC5420",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "GRIMM-CPC5420 Scanning Mobility Particle Counter and Sizer",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729551",
    "VocabularyId" : "233",
    "Identifier" : "GRIMM-CPC5420",
    "Label" : "GRIMM-CPC5420 Scanning Mobility Particle Counter and Sizer",
    "Definition" : null,
    "Notation" : "GRIMM-CPC5420",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-23",
    "AcceptedDate" : "2024-08-23",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6003" ]
  }, {
    "@id" : "GRIMM-EDM107",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "GRIMM model EDM 107 for PM10 PM2.5 PM1 and TC",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729552",
    "VocabularyId" : "233",
    "Identifier" : "GRIMM-EDM107",
    "Label" : "GRIMM model EDM 107 for PM10 PM2.5 PM1 and TC",
    "Definition" : null,
    "Notation" : "GRIMM EDM 107",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "http://www.grimm-aerosol.com/downloads/datasheets/en/GrimmAerosolTechnik_Enviro_EDM107.pdf" ],
    "skos:example" : [ "The GRIMM model 107 monitor is designed to measure particle size distribution and particulate mass based on a light scattering measurement of individual particles in the sampled air" ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5" ]
  }, {
    "@id" : "GRIMM-EDM180",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "GRIMM model EDM 180 for PM10 and PM2.5",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729553",
    "VocabularyId" : "233",
    "Identifier" : "GRIMM-EDM180",
    "Label" : "GRIMM model EDM 180 for PM10 and PM2.5",
    "Definition" : null,
    "Notation" : "GRIMM EDM 180",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5" ]
  }, {
    "@id" : "GRIMM-EDM180C",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "GRIMM model EDM 180-C for PM10 and PM2.5",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729554",
    "VocabularyId" : "233",
    "Identifier" : "GRIMM-EDM180C",
    "Label" : "GRIMM model EDM 180-C for PM10 and PM2.5",
    "Definition" : null,
    "Notation" : "GRIMM-EDM180C",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5" ]
  }, {
    "@id" : "GRIMM-EDM180D",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "GRIMM model EDM 180-D for PM10 PM2.5 PM1 and TC",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729555",
    "VocabularyId" : "233",
    "Identifier" : "GRIMM-EDM180D",
    "Label" : "GRIMM model EDM 180-D for PM10 PM2.5 PM1 and TC",
    "Definition" : null,
    "Notation" : "GRIMM-EDM180D",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/4", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6002" ]
  }, {
    "@id" : "GRIMM-EDM180MC",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "GRIMM model EDM 180-MC for PM10 PM2.5 PM1 TC and 31 size channels",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729556",
    "VocabularyId" : "233",
    "Identifier" : "GRIMM-EDM180MC",
    "Label" : "GRIMM model EDM 180-MC for PM10 PM2.5 PM1 TC and 31 size channels",
    "Definition" : null,
    "Notation" : "GRIMM-EDM180MC",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/4", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6002" ]
  }, {
    "@id" : "GRIMM-EDM280",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "GRIMM model EDM 280 for TSP PM10 PM4 PM2.5 PM1 PMcoarse",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729557",
    "VocabularyId" : "233",
    "Identifier" : "GRIMM-EDM280",
    "Label" : "GRIMM model EDM 280 for TSP PM10 PM4 PM2.5 PM1 PMcoarse",
    "Definition" : "GRIMM model EDM 280 for TSP PM10 PM4 PM2.5 PM1 PMcoarse",
    "Notation" : "GRIMM-EDM280",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6002", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5" ]
  }, {
    "@id" : "GRIMM-EDM365",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "GRIMM model EDM 365 for PM10  PM2.5  PM1 and TC",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729558",
    "VocabularyId" : "233",
    "Identifier" : "GRIMM-EDM365",
    "Label" : "GRIMM model EDM 365 for PM10  PM2.5  PM1 and TC",
    "Definition" : null,
    "Notation" : "GRIMM EDM 365",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "http://www.grimm-aerosol.com/downloads/datasheets/en/GrimmAerosolTechnik_Enviro_GeneralCatalogue.pdf" ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6002", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001" ]
  }, {
    "@id" : "GRIMM-SMPS+C420",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Model 5420 SMPS+C Scanning Mobility Particle Counter and Sizer",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729559",
    "VocabularyId" : "233",
    "Identifier" : "GRIMM-SMPS+C420",
    "Label" : "Model 5420 SMPS+C Scanning Mobility Particle Counter and Sizer",
    "Definition" : null,
    "Notation" : "GRIMM-SMPS+C420",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-23",
    "AcceptedDate" : "2024-08-23",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6003" ]
  }, {
    "@id" : "IL-Punkkinen",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "IL-Punkkinen for NO2/NO hourly measurements",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729560",
    "VocabularyId" : "233",
    "Identifier" : "IL-Punkkinen",
    "Label" : "IL-Punkkinen for NO2/NO hourly measurements",
    "Definition" : "Device based on the modified automated Saltzman method by Finnish Meteorological Institute.",
    "Notation" : "IL-Punkkinen",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "Leckel_SEQ47-50",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Leckel SEQ47/50",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729561",
    "VocabularyId" : "233",
    "Identifier" : "Leckel_SEQ47-50",
    "Label" : "Leckel SEQ47/50",
    "Definition" : null,
    "Notation" : "Leckel_SEQ47-50",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "LumexRA-915AM",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "MERCURY MONITOR RA-915AM",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729562",
    "VocabularyId" : "233",
    "Identifier" : "LumexRA-915AM",
    "Label" : "MERCURY MONITOR RA-915AM",
    "Definition" : "RA-915AM monitors are designed for continuous mercury measurements in ambient air indoor air and in natural gas. Ideal for permanent unattended installation at air monitoring stations RA-915AM monitor for ambient air allows ultra-sensitive measurements of background Hg concentrations and is compliant with the European standard EN 15852 for ambient air monitoring.The monitors feature fully-automated unattended operation without the need for the monthly technician maintenance and frequent recalibration. The use of the instrument allows cutting down operation costs as the analyzer requires no argon cylinders for operation and no consumables.The remote data transfer makes it possible to connect the monitor to data collection systems via RS232 Modbus and analogue output.",
    "Notation" : "LumexRA-915AM",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "LumexRA-915M",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Lumex RA-915M mercury vapor analyzer",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729563",
    "VocabularyId" : "233",
    "Identifier" : "LumexRA-915M",
    "Label" : "Lumex RA-915M mercury vapor analyzer",
    "Definition" : "Mercury Analyzer is a portable multifunctional atomic absorption spectrometer with Zeeman background correction  which eliminates the effect of interfering impurities. It is the only high sensitivity and selectivity instrument that does not require gold amalgam pre-concentration and subsequent regeneration steps. This enables the user to conduct real time air monitoring and detection of mercury vapor. Being combined with pyrolysis or cold vapour attachments for liquid and solid sample testing  the instrument can determine mercury content in water  soil  food products  natural and stack gases  may be used for dental and toxicological applications  etc.",
    "Notation" : "LumexRA-915M",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "MELOY_NA530R",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "MELOY_NA530R",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729564",
    "VocabularyId" : "233",
    "Identifier" : "MELOY_NA530R",
    "Label" : "MELOY_NA530R",
    "Definition" : "Nitrogen Oxides Analyzer",
    "Notation" : "MELOY_NA530R",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-12-12",
    "AcceptedDate" : "2024-12-12",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9" ]
  }, {
    "@id" : "MELOY_SA285E",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "MELOY SA285E",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729565",
    "VocabularyId" : "233",
    "Identifier" : "MELOY_SA285E",
    "Label" : "MELOY SA285E",
    "Definition" : "SO2 Analyzer",
    "Notation" : "MELOY_SA285E",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-12-12",
    "AcceptedDate" : "2024-12-12",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "ML",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "ML",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729566",
    "VocabularyId" : "233",
    "Identifier" : "ML",
    "Label" : "ML",
    "Definition" : null,
    "Notation" : "ML",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "check pollutant" ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "ML2010",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Monitor Labs model 2010 O3 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729567",
    "VocabularyId" : "233",
    "Identifier" : "ML2010",
    "Label" : "Monitor Labs model 2010 O3 analyser",
    "Definition" : null,
    "Notation" : "ML2010",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "ML2030",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Monitor Labs model 2030 CO analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729568",
    "VocabularyId" : "233",
    "Identifier" : "ML2030",
    "Label" : "Monitor Labs model 2030 CO analyser",
    "Definition" : null,
    "Notation" : "ML2030",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "ML2040",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Monitor Labs model 2040 SO2 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729569",
    "VocabularyId" : "233",
    "Identifier" : "ML2040",
    "Label" : "Monitor Labs model 2040 SO2 analyser",
    "Definition" : null,
    "Notation" : "ML2040",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "ML2041",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Monitor Labs model 2041 NOx analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729570",
    "VocabularyId" : "233",
    "Identifier" : "ML2041",
    "Label" : "Monitor Labs model 2041 NOx analyser",
    "Definition" : null,
    "Notation" : "ML2041",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9" ]
  }, {
    "@id" : "ML2050",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Monitor Labs model 2050 SO2 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729571",
    "VocabularyId" : "233",
    "Identifier" : "ML2050",
    "Label" : "Monitor Labs model 2050 SO2 analyser",
    "Definition" : null,
    "Notation" : "ML2050",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "ML8410",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Monitor Labs model 8410 NOx analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729572",
    "VocabularyId" : "233",
    "Identifier" : "ML8410",
    "Label" : "Monitor Labs model 8410 NOx analyser",
    "Definition" : "Monitor Labs model 8410 NOx analyser",
    "Notation" : "ML8410",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8" ]
  }, {
    "@id" : "ML8440",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Monitor Labs model 8440 NOx analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729573",
    "VocabularyId" : "233",
    "Identifier" : "ML8440",
    "Label" : "Monitor Labs model 8440 NOx analyser",
    "Definition" : null,
    "Notation" : "ML8440",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "check pollutant" ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9" ]
  }, {
    "@id" : "ML8441",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Monitor Labs model 8841 NOx analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729574",
    "VocabularyId" : "233",
    "Identifier" : "ML8441",
    "Label" : "Monitor Labs model 8841 NOx analyser",
    "Definition" : null,
    "Notation" : "ML8441",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "check pollutant" ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9" ]
  }, {
    "@id" : "ML8810",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Monitor Labs model 8810 O3 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729575",
    "VocabularyId" : "233",
    "Identifier" : "ML8810",
    "Label" : "Monitor Labs model 8810 O3 analyser",
    "Definition" : null,
    "Notation" : "ML8810",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "check pollutant" ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "ML8830",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Monitor Labs model 8830 CO analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729576",
    "VocabularyId" : "233",
    "Identifier" : "ML8830",
    "Label" : "Monitor Labs model 8830 CO analyser",
    "Definition" : null,
    "Notation" : "ML8830",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "check pollutant" ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "ML8831",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Monitor Labs model 8831 CO analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729577",
    "VocabularyId" : "233",
    "Identifier" : "ML8831",
    "Label" : "Monitor Labs model 8831 CO analyser",
    "Definition" : null,
    "Notation" : "ML8831",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "check pollutant" ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "ML8840",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Monitor Labs model 8840 NOx analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729578",
    "VocabularyId" : "233",
    "Identifier" : "ML8840",
    "Label" : "Monitor Labs model 8840 NOx analyser",
    "Definition" : null,
    "Notation" : "ML8840",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "check pollutant" ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9" ]
  }, {
    "@id" : "ML8841",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Monitor Labs model 8841 NOx analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729579",
    "VocabularyId" : "233",
    "Identifier" : "ML8841",
    "Label" : "Monitor Labs model 8841 NOx analyser",
    "Definition" : null,
    "Notation" : "ML8841",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "check pollutant" ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9" ]
  }, {
    "@id" : "ML8850",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Monitor Labs model 8850 SO2 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729580",
    "VocabularyId" : "233",
    "Identifier" : "ML8850",
    "Label" : "Monitor Labs model 8850 SO2 analyser",
    "Definition" : null,
    "Notation" : "ML8850",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "check pollutant" ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "ML8850M",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Monitor Labs model 8850M SO2 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729581",
    "VocabularyId" : "233",
    "Identifier" : "ML8850M",
    "Label" : "Monitor Labs model 8850M SO2 analyser",
    "Definition" : null,
    "Notation" : "ML8850M",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "check pollutant" ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "ML8850S",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Monitor Labs model 8850S SO2 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729582",
    "VocabularyId" : "233",
    "Identifier" : "ML8850S",
    "Label" : "Monitor Labs model 8850S SO2 analyser",
    "Definition" : null,
    "Notation" : "ML8850S",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "check pollutant" ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "ML8930",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Monitor Labs model 8930 CO analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729583",
    "VocabularyId" : "233",
    "Identifier" : "ML8930",
    "Label" : "Monitor Labs model 8930 CO analyser",
    "Definition" : "Monitor Labs model 8930 CO analyser",
    "Notation" : "ML8930",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "ML8941A",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Monitor Labs model 8941A NOx analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729584",
    "VocabularyId" : "233",
    "Identifier" : "ML8941A",
    "Label" : "Monitor Labs model 8941A NOx analyser",
    "Definition" : null,
    "Notation" : "ML8941A",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "check pollutant" ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38" ]
  }, {
    "@id" : "ML9800",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Monitor Labs model 9800",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729585",
    "VocabularyId" : "233",
    "Identifier" : "ML9800",
    "Label" : "Monitor Labs model 9800",
    "Definition" : null,
    "Notation" : "ML9800",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "check pollutant" ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "ML9810",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Monitor Labs model 9810 O3 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729586",
    "VocabularyId" : "233",
    "Identifier" : "ML9810",
    "Label" : "Monitor Labs model 9810 O3 analyser",
    "Definition" : null,
    "Notation" : "ML9810",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "ML9810A",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Monitor Labs model 9810A O3 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729587",
    "VocabularyId" : "233",
    "Identifier" : "ML9810A",
    "Label" : "Monitor Labs model 9810A O3 analyser",
    "Definition" : null,
    "Notation" : "ML9810A",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "ML9810B",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Monitor Labs model 9810B O3 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729588",
    "VocabularyId" : "233",
    "Identifier" : "ML9810B",
    "Label" : "Monitor Labs model 9810B O3 analyser",
    "Definition" : null,
    "Notation" : "ML9810B",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "ML9811",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Monitor Labs model 9811 O3 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729589",
    "VocabularyId" : "233",
    "Identifier" : "ML9811",
    "Label" : "Monitor Labs model 9811 O3 analyser",
    "Definition" : null,
    "Notation" : "ML9811",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "ML9812",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Monitor Labs model 9812 O3 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729590",
    "VocabularyId" : "233",
    "Identifier" : "ML9812",
    "Label" : "Monitor Labs model 9812 O3 analyser",
    "Definition" : null,
    "Notation" : "ML9812",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "ML9830",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Monitor Labs model 9830 CO analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729591",
    "VocabularyId" : "233",
    "Identifier" : "ML9830",
    "Label" : "Monitor Labs model 9830 CO analyser",
    "Definition" : null,
    "Notation" : "ML9830",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "ML9830B",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Monitor Labs model 9830B CO analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729592",
    "VocabularyId" : "233",
    "Identifier" : "ML9830B",
    "Label" : "Monitor Labs model 9830B CO analyser",
    "Definition" : null,
    "Notation" : "ML9830B",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "ML9832",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Monitor Labs model 9832 CO analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729593",
    "VocabularyId" : "233",
    "Identifier" : "ML9832",
    "Label" : "Monitor Labs model 9832 CO analyser",
    "Definition" : null,
    "Notation" : "ML9832",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "ML9840",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Monitor Labs model 9840 NOx analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729594",
    "VocabularyId" : "233",
    "Identifier" : "ML9840",
    "Label" : "Monitor Labs model 9840 NOx analyser",
    "Definition" : null,
    "Notation" : "ML9840",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9" ]
  }, {
    "@id" : "ML9841",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Monitor Labs model 9841 NOx analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729595",
    "VocabularyId" : "233",
    "Identifier" : "ML9841",
    "Label" : "Monitor Labs model 9841 NOx analyser",
    "Definition" : null,
    "Notation" : "ML9841",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38" ]
  }, {
    "@id" : "ML9841A",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Monitor Labs model 9841A NOx analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729596",
    "VocabularyId" : "233",
    "Identifier" : "ML9841A",
    "Label" : "Monitor Labs model 9841A NOx analyser",
    "Definition" : null,
    "Notation" : "ML9841A",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8" ]
  }, {
    "@id" : "ML9841B",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Monitor Labs model 9841B NOx analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729597",
    "VocabularyId" : "233",
    "Identifier" : "ML9841B",
    "Label" : "Monitor Labs model 9841B NOx analyser",
    "Definition" : null,
    "Notation" : "ML9841B",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8" ]
  }, {
    "@id" : "ML9841T",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Monitor Labs model 9841T NOx analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729598",
    "VocabularyId" : "233",
    "Identifier" : "ML9841T",
    "Label" : "Monitor Labs model 9841T NOx analyser",
    "Definition" : null,
    "Notation" : "ML9841T",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9" ]
  }, {
    "@id" : "ML9850",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Monitor Labs model 9850 SO2 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729599",
    "VocabularyId" : "233",
    "Identifier" : "ML9850",
    "Label" : "Monitor Labs model 9850 SO2 analyser",
    "Definition" : null,
    "Notation" : "ML9850",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "ML9850B",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Monitor Labs model 9850B SO2 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729600",
    "VocabularyId" : "233",
    "Identifier" : "ML9850B",
    "Label" : "Monitor Labs model 9850B SO2 analyser",
    "Definition" : null,
    "Notation" : "ML9850B",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "MRI_1550B",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "MRI_1550B",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729601",
    "VocabularyId" : "233",
    "Identifier" : "MRI_1550B",
    "Label" : "MRI_1550B",
    "Definition" : "The MRI Integrating nephelometer is used to measure the scattering coefficient of the air, caused by aerosol particulates.",
    "Notation" : "MRI_1550B",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-12-12",
    "AcceptedDate" : "2024-12-12",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/391" ]
  }, {
    "@id" : "NIRA-Venus301",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "NIRA-Venus301",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729602",
    "VocabularyId" : "233",
    "Identifier" : "NIRA-Venus301",
    "Label" : "NIRA-Venus301",
    "Definition" : "NIRA-Venus301",
    "Notation" : "NIRA-Venus301",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "PNS18-DM-3.1",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "PNS 18-DM-3.1",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729603",
    "VocabularyId" : "233",
    "Identifier" : "PNS18-DM-3.1",
    "Label" : "PNS 18-DM-3.1",
    "Definition" : "The PNS DM consists of a low/medium volume sampler (LVS or MVS) and a filter changer with intake tube and sampling inlet. It collects fine particulate matter on sampling filters according to EN 12341:2014 (PM10 and PM2.5).",
    "Notation" : "PNS18-DM-3.1",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "PNS18-DM-6.1",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "PNS 18-DM-6.1",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729604",
    "VocabularyId" : "233",
    "Identifier" : "PNS18-DM-6.1",
    "Label" : "PNS 18-DM-6.1",
    "Definition" : "The PNS DM consists of a low/medium volume sampler (LVS or MVS) and a filter changer with intake tube and sampling inlet. It collects fine particulate matter on sampling filters according to EN 12341:2014 (PM10 and PM2.5).",
    "Notation" : "PNS18-DM-6.1",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "PNS18T-DM-3.1",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "PNS 18T-DM-3.1",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729605",
    "VocabularyId" : "233",
    "Identifier" : "PNS18T-DM-3.1",
    "Label" : "PNS 18T-DM-3.1",
    "Definition" : "The PNS T-DM combines a low / medium volume sampler (LVS or MVS) and a filter changer in a stainless steel cabinet. It collects fine particulate matter on sampling filters according to EN 12341:2014 (PM10 and PM2.5).",
    "Notation" : "PNS18T-DM-3.1",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "PNS18T-DM-6.1",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "PNS 18T-DM-6.1",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729606",
    "VocabularyId" : "233",
    "Identifier" : "PNS18T-DM-6.1",
    "Label" : "PNS 18T-DM-6.1",
    "Definition" : "The PNS T-DM combines a low / medium volume sampler (LVS or MVS) and a filter changer in a stainless steel cabinet. It collects fine particulate matter on sampling filters according to EN 12341:2014 (PM10 and PM2.5).",
    "Notation" : "PNS18T-DM-6.1",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "PNS24-DM-3.1",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "PNS 24-DM-3.1",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729607",
    "VocabularyId" : "233",
    "Identifier" : "PNS24-DM-3.1",
    "Label" : "PNS 24-DM-3.1",
    "Definition" : "The PNS DM consists of a low/medium volume sampler (LVS or MVS) and a filter changer with intake tube and sampling inlet. It collects fine particulate matter on sampling filters according to EN 12341:2014 (PM10 and PM2.5).",
    "Notation" : "PNS24-DM-3.1",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "PNS24-DM-6.1",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "PNS 24-DM-6.1",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729608",
    "VocabularyId" : "233",
    "Identifier" : "PNS24-DM-6.1",
    "Label" : "PNS 24-DM-6.1",
    "Definition" : "The PNS DM consists of a low/medium volume sampler (LVS or MVS) and a filter changer with intake tube and sampling inlet. It collects fine particulate matter on sampling filters according to EN 12341:2014 (PM10 and PM2.5).",
    "Notation" : "PNS24-DM-6.1",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "PNS24T-DM-3.1",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "PNS 24T-DM-3.1",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729609",
    "VocabularyId" : "233",
    "Identifier" : "PNS24T-DM-3.1",
    "Label" : "PNS 24T-DM-3.1",
    "Definition" : "The PNS T-DM combines a low / medium volume sampler (LVS or MVS) and a filter changer in a stainless steel cabinet. It collects fine particulate matter on sampling filters according to EN 12341:2014 (PM10 and PM2.5).",
    "Notation" : "PNS24T-DM-3.1",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "PNS24T-DM-6.1",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "PNS 24T-DM-6.1",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729610",
    "VocabularyId" : "233",
    "Identifier" : "PNS24T-DM-6.1",
    "Label" : "PNS 24T-DM-6.1",
    "Definition" : "The PNS T-DM combines a low / medium volume sampler (LVS or MVS) and a filter changer in a stainless steel cabinet. It collects fine particulate matter on sampling filters according to EN 12341:2014 (PM10 and PM2.5).",
    "Notation" : "PNS24T-DM-6.1",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "Passive_Palmes_Tube",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Passive Palmes Tube",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729611",
    "VocabularyId" : "233",
    "Identifier" : "Passive_Palmes_Tube",
    "Label" : "Passive Palmes Tube",
    "Definition" : "Passive Palmes Tube. Generally for NO2. However  available for other substances like NOX-NO  SO2  O3  C6H6...",
    "Notation" : "Passive_Palmes_Tube",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "PicarroG2301",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Picarro G2301 Gas Concentration Analyzer",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729612",
    "VocabularyId" : "233",
    "Identifier" : "PicarroG2301",
    "Label" : "Picarro G2301 Gas Concentration Analyzer",
    "Definition" : "The Picarro G2301 gas concentration analyzer provides simultaneous, precise measurement of carbon dioxide (CO2) - methane (CH4) at parts-per-billion (ppb) and water (H2O) vapor at parts-per-million (ppm) sensitivity with negligible drift for atmospheric science air quality and emissions quantification. It meets the World Meteorological Organization (WMO) and Integrated Carbon Observation System (ICOS) performance requirements for CO2 and CH4 atmospheric monitoring.",
    "Notation" : "PicarroG2301",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-23",
    "AcceptedDate" : "2024-08-23",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/41", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/71" ]
  }, {
    "@id" : "PicarroG2401",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Picarro G2401 (used for CO measurement)",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729613",
    "VocabularyId" : "233",
    "Identifier" : "PicarroG2401",
    "Label" : "Picarro G2401 (used for CO measurement)",
    "Definition" : null,
    "Notation" : "PicarroG2401",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "R&P5400",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "RUPPRECHT & PATASHNICK, SERIES 5400 CARBON MONITOR",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729614",
    "VocabularyId" : "233",
    "Identifier" : "R&P5400",
    "Label" : "RUPPRECHT & PATASHNICK, SERIES 5400 CARBON MONITOR",
    "Definition" : "The Series 5400 is an automatic speciation analyzer of suspended particulate matter. It measures the elemental \r\nand organic carbon contained in suspended particulate matter at averaging times as short as one hour.",
    "Notation" : "R&P5400",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-23",
    "AcceptedDate" : "2024-08-23",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/772", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/771" ]
  }, {
    "@id" : "SFIO342M",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "SFI O342M",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729615",
    "VocabularyId" : "233",
    "Identifier" : "SFIO342M",
    "Label" : "SFI O342M",
    "Definition" : null,
    "Notation" : "SFIO342M",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "SIR-S-5001",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "SIR S-5001",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729616",
    "VocabularyId" : "233",
    "Identifier" : "SIR-S-5001",
    "Label" : "SIR S-5001",
    "Definition" : "The SIR Model S-5001 is a Non-Pulsed U.V. Fluorescence Sulfur Dioxide Analyzer. In the nalyzer  optically filtered pure monochromatic U.V. light from a Zinc lamp is focused onto the SO2 reaction chamber.",
    "Notation" : "SIR-S-5001",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "SIR-S-5006",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "SIR S-5006",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729617",
    "VocabularyId" : "233",
    "Identifier" : "SIR-S-5006",
    "Label" : "SIR S-5006",
    "Definition" : "The SIR Model S-5006 is a Non-Dispersive Infrared (NDIR) Analyzer for the measurement of Carbon Monoxide concentrations in ambient air",
    "Notation" : "SIR-S-5006",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "SIR-S-5012",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "SIR S-5012",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729618",
    "VocabularyId" : "233",
    "Identifier" : "SIR-S-5012",
    "Label" : "SIR S-5012",
    "Definition" : "The SIR Model S-5012 Nitrogen Oxides Analyzer is designed to measure the amount of nitric oxide (NO)  nitrogen dioxide (NO2) and total oxides of nitrogen (NOx) in a continuous  ambient air sample",
    "Notation" : "SIR-S-5012",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9" ]
  }, {
    "@id" : "SIR-S-5014",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "SIR S-5014",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729619",
    "VocabularyId" : "233",
    "Identifier" : "SIR-S-5014",
    "Label" : "SIR S-5014",
    "Definition" : "SIR Model S-5014 ozone analyser is a self-contained instrument which measures the concentration of ozone in a sample of ambient background) gas  such as air  oxygen  nitrogen  etc",
    "Notation" : "SIR-S-5014",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "SRI8610",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "SRI 8610",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729620",
    "VocabularyId" : "233",
    "Identifier" : "SRI8610",
    "Label" : "SRI 8610",
    "Definition" : null,
    "Notation" : "SRI8610",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "SRI8610-C",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "SRI8610-C",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729621",
    "VocabularyId" : "233",
    "Identifier" : "SRI8610-C",
    "Label" : "SRI8610-C",
    "Definition" : "Compact gas chromatograph",
    "Notation" : "SRI8610-C",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ "BTEX/VOC" ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/482", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/20", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/80", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/431", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/33", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/21" ]
  }, {
    "@id" : "SWAM5aDual",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "SWAM 5a Dual channel monitor",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729622",
    "VocabularyId" : "233",
    "Identifier" : "SWAM5aDual",
    "Label" : "SWAM 5a Dual channel monitor",
    "Definition" : null,
    "Notation" : "SWAM5aDual",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5" ]
  }, {
    "@id" : "SWAM5aSingle",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "SWAM 5a Single channel monitor",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729623",
    "VocabularyId" : "233",
    "Identifier" : "SWAM5aSingle",
    "Label" : "SWAM 5a Single channel monitor",
    "Definition" : "FAI SWAM5a Single Channel",
    "Notation" : "SWAM5aSingle",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001" ]
  }, {
    "@id" : "Serinus10",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Serinus 10 O3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729624",
    "VocabularyId" : "233",
    "Identifier" : "Serinus10",
    "Label" : "Serinus 10 O3",
    "Definition" : null,
    "Notation" : "Serinus10",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "Serinus30",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Serinus30 CO",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729625",
    "VocabularyId" : "233",
    "Identifier" : "Serinus30",
    "Label" : "Serinus30 CO",
    "Definition" : null,
    "Notation" : "Serinus30",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "Serinus50",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Serinus 50 SO2",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729626",
    "VocabularyId" : "233",
    "Identifier" : "Serinus50",
    "Label" : "Serinus 50 SO2",
    "Definition" : null,
    "Notation" : "Serinus50",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "TEOM1400",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "TEOM 1400",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729627",
    "VocabularyId" : "233",
    "Identifier" : "TEOM1400",
    "Label" : "TEOM 1400",
    "Definition" : null,
    "Notation" : "TEOM1400",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "assumed 1400" ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001" ]
  }, {
    "@id" : "TEOM1400A",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "TEOM 1400A",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729628",
    "VocabularyId" : "233",
    "Identifier" : "TEOM1400A",
    "Label" : "TEOM 1400A",
    "Definition" : null,
    "Notation" : "TEOM1400A",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5" ]
  }, {
    "@id" : "TEOM1400AB",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "TEOM 1400AB",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729629",
    "VocabularyId" : "233",
    "Identifier" : "TEOM1400AB",
    "Label" : "TEOM 1400AB",
    "Definition" : null,
    "Notation" : "TEOM1400AB",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001" ]
  }, {
    "@id" : "TEOM1400AB-FDMS",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "TEOM 1400AB with FDMS module (8500)",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729630",
    "VocabularyId" : "233",
    "Identifier" : "TEOM1400AB-FDMS",
    "Label" : "TEOM 1400AB with FDMS module (8500)",
    "Definition" : null,
    "Notation" : "TEOM1400AB-FDMS",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "must be AB" ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001" ]
  }, {
    "@id" : "TEOM1400FDMS-8500B-CB",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "TEOM 1400 FDMS + 8500 B or CB Dryer",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729631",
    "VocabularyId" : "233",
    "Identifier" : "TEOM1400FDMS-8500B-CB",
    "Label" : "TEOM 1400 FDMS + 8500 B or CB Dryer",
    "Definition" : null,
    "Notation" : "TEOM1400FDMS-8500B-CB",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "TEOM1405",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "TEOM 1405",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729632",
    "VocabularyId" : "233",
    "Identifier" : "TEOM1405",
    "Label" : "TEOM 1405",
    "Definition" : null,
    "Notation" : "TEOM1405",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5" ]
  }, {
    "@id" : "TEOM1405D",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "TEOM 1405D",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729633",
    "VocabularyId" : "233",
    "Identifier" : "TEOM1405D",
    "Label" : "TEOM 1405D",
    "Definition" : null,
    "Notation" : "TEOM1405D",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5" ]
  }, {
    "@id" : "TEOM1405DF-FDMS",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "TEOM 1405DF with FDMS Dichotomous monitor for PM2.5 & PM10",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729634",
    "VocabularyId" : "233",
    "Identifier" : "TEOM1405DF-FDMS",
    "Label" : "TEOM 1405DF with FDMS Dichotomous monitor for PM2.5 & PM10",
    "Definition" : null,
    "Notation" : "TEOM1405DF-FDMS",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001" ]
  }, {
    "@id" : "TEOM1405F-FDMS",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "TEOM 1405F with FDMS",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729635",
    "VocabularyId" : "233",
    "Identifier" : "TEOM1405F-FDMS",
    "Label" : "TEOM 1405F with FDMS",
    "Definition" : null,
    "Notation" : "TEOM1405F-FDMS",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001" ]
  }, {
    "@id" : "THERMO450i",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "THERMO 450i",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729636",
    "VocabularyId" : "233",
    "Identifier" : "THERMO450i",
    "Label" : "THERMO 450i",
    "Definition" : null,
    "Notation" : "THERMO450i",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "THERMO450iQ",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "THERMO450iQ",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729637",
    "VocabularyId" : "233",
    "Identifier" : "THERMO450iQ",
    "Label" : "THERMO450iQ",
    "Definition" : "The 450iQ analyzer operates on the principle that H2S can be converted \r\nto SO2. As the SO2 molecules absorb ultraviolet (UV) light and become excited at one wavelength, the molecules then decay to a lower energy state emitting UV light at a different wavelength.",
    "Notation" : "THERMO450iQ",
    "Status" : "Valid",
    "StatusModifiedDate" : "2025-07-29",
    "AcceptedDate" : "2025-07-29",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/11", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "TSI3022ACPC",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "TSI 3022A CPC",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729638",
    "VocabularyId" : "233",
    "Identifier" : "TSI3022ACPC",
    "Label" : "TSI 3022A CPC",
    "Definition" : "The Model 3022A Condensation Particle Counter detects particles down to 7 nm in diameter. Using both single-count and photometric detection modes  it provides highly accurate measurements for concentrations as high as 107particles/cm3.",
    "Notation" : "TSI3022ACPC",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "TSI3031",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "TSI Ultrafine Particle Monitor 3031",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729639",
    "VocabularyId" : "233",
    "Identifier" : "TSI3031",
    "Label" : "TSI Ultrafine Particle Monitor 3031",
    "Definition" : "The Ultrafine Particle Monitor Model 3031 is specifically designed to measure ultrafine particles long-term. It reports the particle number concentration in six size classes between 20 and 500 nm and requires only minimal maintenance.",
    "Notation" : "TSI3031",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-23",
    "AcceptedDate" : "2024-08-23",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6003" ]
  }, {
    "@id" : "TSI3080SMPS",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "TSI Electrostatic Classifier 3080",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729640",
    "VocabularyId" : "233",
    "Identifier" : "TSI3080SMPS",
    "Label" : "TSI Electrostatic Classifier 3080",
    "Definition" : "TSI's Electrostatic Classifiers 3080 Series produce highly monodisperse, submicrometer aerosol. They have been used in a variety of aerosol-generation or particle-sizing applications with highly accurate and repeatable results.",
    "Notation" : "TSI3080SMPS",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-23",
    "AcceptedDate" : "2024-08-23",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6003" ]
  }, {
    "@id" : "TSI3550NSAM",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "TSI Nanoparticle Surface Area Monitor 3550",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729641",
    "VocabularyId" : "233",
    "Identifier" : "TSI3550NSAM",
    "Label" : "TSI Nanoparticle Surface Area Monitor 3550",
    "Definition" : "The Nanoparticle Surface Area Monitor 3550 (NSAM) measures the human lung-deposited surface area of particles (reported as µm 2 /cm 3 ) corresponding to tracheobronchial (TB) and alveolar (A) regions of the lung. The NSAM 3550 provides a simple and fast solution for measuring the surface area equivalent dose in the lung. It is an important instrument for research in the fields of inhalation toxicology health effects and epidemiology and for measuring and monitoring workplace exposure.",
    "Notation" : "TSI3550NSAM",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-23",
    "AcceptedDate" : "2024-08-23",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6003" ]
  }, {
    "@id" : "TSI3750CPC",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "TSI Condensation Particle Counter 3750",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729642",
    "VocabularyId" : "233",
    "Identifier" : "TSI3750CPC",
    "Label" : "TSI Condensation Particle Counter 3750",
    "Definition" : "Enables ambient air monitoring stations to measure size distributions of ultrafine particles in compliance with CEN/TS 17434:2020.",
    "Notation" : "TSI3750CPC",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-23",
    "AcceptedDate" : "2024-08-23",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6003" ]
  }, {
    "@id" : "TSI3752CPC",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "TSI model 3752 High Concentration Condensation Particle Counter",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729643",
    "VocabularyId" : "233",
    "Identifier" : "TSI3752CPC",
    "Label" : "TSI model 3752 High Concentration Condensation Particle Counter",
    "Definition" : "TSI Condensation Particle Counters (CPCs)",
    "Notation" : "TSI3752CPC",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6003" ]
  }, {
    "@id" : "TSI3772CPC",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "TSI Condensation Particle Counter 3772",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729644",
    "VocabularyId" : "233",
    "Identifier" : "TSI3772CPC",
    "Label" : "TSI Condensation Particle Counter 3772",
    "Definition" : "Condensation Particle Counter Model 3772 is a compact rugged and full-featured instrument that detects airborne particles down to 10 nm at an aerosol flow rate of 1.0 L/min over a concentration range from 0 to 10000 particles/cm 3. It is ideally suited for applications that do not require measurement of high concentrations.",
    "Notation" : "TSI3772CPC",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-23",
    "AcceptedDate" : "2024-08-23",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6003" ]
  }, {
    "@id" : "TSI3775CPC",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "TSI model 3775 Condensation Particle Counter",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729645",
    "VocabularyId" : "233",
    "Identifier" : "TSI3775CPC",
    "Label" : "TSI model 3775 Condensation Particle Counter",
    "Definition" : "TSI model 3775 Condensation Particle Counter (Discontinued)",
    "Notation" : "TSI3775CPC",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6003" ]
  }, {
    "@id" : "TSI3776UCPC",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "TSI Ultrafine Condensation Particle Counter (UCPC) Model 3776",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729646",
    "VocabularyId" : "233",
    "Identifier" : "TSI3776UCPC",
    "Label" : "TSI Ultrafine Condensation Particle Counter (UCPC) Model 3776",
    "Definition" : "The Ultrafine Condensation Particle Counter 3776 (UCPC) a types of condensation particle counter (CPC) is designed primarily for researchers interested in airborne particles smaller than 20 nm. It is a continuous-flow instrument that detects particles down to 2.5 nm. It uses a special sheath-air flow design that improves response to changes in particle concentration and increases counting efficiency for ultrafine particles.",
    "Notation" : "TSI3776UCPC",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-23",
    "AcceptedDate" : "2024-08-23",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6003" ]
  }, {
    "@id" : "TSI3783",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "TSI3783",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729647",
    "VocabularyId" : "233",
    "Identifier" : "TSI3783",
    "Label" : "TSI3783",
    "Definition" : "TSI’s EPC™Monitor Model 3783 provides continuous, high\r\n precision airborne particle number concentration\r\n measurements",
    "Notation" : "TSI3783",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-12-12",
    "AcceptedDate" : "2024-12-12",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6003" ]
  }, {
    "@id" : "TSI3936SMPS",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "TSI 3936 SMPS",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729648",
    "VocabularyId" : "233",
    "Identifier" : "TSI3936SMPS",
    "Label" : "TSI 3936 SMPS",
    "Definition" : null,
    "Notation" : "TSI3936SMPS",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "TSISMPS3938",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "TSISMPS3938",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729649",
    "VocabularyId" : "233",
    "Identifier" : "TSISMPS3938",
    "Label" : "TSISMPS3938",
    "Definition" : "General Scanning Mobility Particle Sizer",
    "Notation" : "TSISMPS3938",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-12-12",
    "AcceptedDate" : "2024-12-12",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "Thermo17i",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo 17i",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729650",
    "VocabularyId" : "233",
    "Identifier" : "Thermo17i",
    "Label" : "Thermo 17i",
    "Definition" : "The Thermo Scientific Model 17i Ammonia Analyzer uses the light producing reaction of nitric oxide (NO) with ozone (O3) as its basic principle. The instrument has three modes of operation  NO  NOx and Nt.",
    "Notation" : "Thermo17i",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/44", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/35" ]
  }, {
    "@id" : "Thermo49iq",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "THERMO49iq",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729651",
    "VocabularyId" : "233",
    "Identifier" : "Thermo49iq",
    "Label" : "THERMO49iq",
    "Definition" : "With ultraviolet photometry technology. High stability and low detection limit (0.5 ppm)",
    "Notation" : "Thermo49iq",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "URG",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "URG",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729652",
    "VocabularyId" : "233",
    "Identifier" : "URG",
    "Label" : "URG",
    "Definition" : null,
    "Notation" : "URG",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "VOC71M",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Environnement VOC71M",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729653",
    "VocabularyId" : "233",
    "Identifier" : "VOC71M",
    "Label" : "Environnement VOC71M",
    "Definition" : null,
    "Notation" : "VOC71M",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ "other VOC" ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/20" ]
  }, {
    "@id" : "VOC72M",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Environnement VOC72M",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729654",
    "VocabularyId" : "233",
    "Identifier" : "VOC72M",
    "Label" : "Environnement VOC72M",
    "Definition" : null,
    "Notation" : "VOC72M",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/21", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/81", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/431", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/24", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/482", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/80", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/464", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/20" ]
  }, {
    "@id" : "WoesthoffU3S",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Woesthoff U3S",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729655",
    "VocabularyId" : "233",
    "Identifier" : "WoesthoffU3S",
    "Label" : "Woesthoff U3S",
    "Definition" : "Woesthoff U3S",
    "Notation" : "WoesthoffU3S",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "aerisAE2010U",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Aeris AE2010U",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729656",
    "VocabularyId" : "233",
    "Identifier" : "aerisAE2010U",
    "Label" : "Aeris AE2010U",
    "Definition" : "The aeris® AE2010U Trace Level Ozone (03) Analyser employs a non-dispersive ultraviolet (UV) absorption",
    "Notation" : "aerisAE2010U",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "aerisAE2030U",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Aeris AE2030U",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729657",
    "VocabularyId" : "233",
    "Identifier" : "aerisAE2030U",
    "Label" : "Aeris AE2030U",
    "Definition" : "The aeris® AE2030U Trace Level Carbon monoxide (CO) analyser employs a n on-dispersive infrared (NDIR) photometer to measure very low concentrations of CO",
    "Notation" : "aerisAE2030U",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "aerisAE2041U",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Aeris AE2041U",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729658",
    "VocabularyId" : "233",
    "Identifier" : "aerisAE2041U",
    "Label" : "Aeris AE2041U",
    "Definition" : "The aeris® AE2041U Trace Level NO/NO2/NOx chemiluminescence analyser incorporates a single-channel design measuring NO and NOx",
    "Notation" : "aerisAE2041U",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38" ]
  }, {
    "@id" : "aerisAE2050U",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Aeris AE2050U",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729659",
    "VocabularyId" : "233",
    "Identifier" : "aerisAE2050U",
    "Label" : "Aeris AE2050U",
    "Definition" : "The aeris® AE2050U Trace Level Sulphur Dioxide (S02) Analyser employs pulsed UV fluorescent radiation technology",
    "Notation" : "aerisAE2050U",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "aerodyneACSM",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Aerodyne ACSM",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729660",
    "VocabularyId" : "233",
    "Identifier" : "aerodyneACSM",
    "Label" : "Aerodyne ACSM",
    "Definition" : "The Aerosol Chemical Speciation Monitor (ACSM) measures mass loading and chemical composition of non-refractory aerosol particles in real-time. Smaller  lower cost  more robust  and simpler to operate than our AMS instruments  the ACSM is designed for long-term unattended deployment and routine monitoring applications.",
    "Notation" : "aerodyneACSM",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "agilentHP6890",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "agilent HP 6890",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729661",
    "VocabularyId" : "233",
    "Identifier" : "agilentHP6890",
    "Label" : "agilent HP 6890",
    "Definition" : "Agilent HP 6890 (used for benzene and toluene measurement)",
    "Notation" : "agilentHP6890",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/20", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/21" ]
  }, {
    "@id" : "airmoOzone",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "CHROMATOTEC airmOzone",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729662",
    "VocabularyId" : "233",
    "Identifier" : "airmoOzone",
    "Label" : "CHROMATOTEC airmOzone",
    "Definition" : "System for analysis of the Ozone precursor VOC",
    "Notation" : "airmoOzone",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "airmoVOC_BTX",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "airmoVOC BTX",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729663",
    "VocabularyId" : "233",
    "Identifier" : "airmoVOC_BTX",
    "Label" : "airmoVOC BTX",
    "Definition" : "The airmoVOC BTX is an automatic gas chromatograph dedicated to the analysis and monitoring of trace amounts of BTEX compounds(Benzene Toluene Ethylbenzene m- p- and o-Xylenes)",
    "Notation" : "airmoVOC_BTX",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2022-12-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/20", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/464", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/21", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/482", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/431" ]
  }, {
    "@id" : "airmoVOC_BTX1000",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "airmotec BTX 1000",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729664",
    "VocabularyId" : "233",
    "Identifier" : "airmoVOC_BTX1000",
    "Label" : "airmotec BTX 1000",
    "Definition" : null,
    "Notation" : "airmoVOC_BTX1000",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/21", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/20", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/464", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/431" ]
  }, {
    "@id" : "airpointer",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "airpointer",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729665",
    "VocabularyId" : "233",
    "Identifier" : "airpointer",
    "Label" : "airpointer",
    "Definition" : "The airpointer‘s modular design comprising a base unit analyzing modules and sensor modules allows for a configurationaccording to different application requirements.",
    "Notation" : "airpointer",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/11", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8" ]
  }, {
    "@id" : "airpointerNephelometer",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Airpointer Nephelometer module",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729666",
    "VocabularyId" : "233",
    "Identifier" : "airpointerNephelometer",
    "Label" : "Airpointer Nephelometer module",
    "Definition" : null,
    "Notation" : "airpointerNephelometer",
    "Status" : "Valid",
    "StatusModifiedDate" : "2025-11-25",
    "AcceptedDate" : "2025-11-25",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001" ]
  }, {
    "@id" : "alpha400",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "SYNSPEC model Alpha 400",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729667",
    "VocabularyId" : "233",
    "Identifier" : "alpha400",
    "Label" : "SYNSPEC model Alpha 400",
    "Definition" : "Benzene analyser model Alpha 400",
    "Notation" : "alpha400",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "andersenFH621N",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Andersen/GMW Model  FH621-N Beta Monitor",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729668",
    "VocabularyId" : "233",
    "Identifier" : "andersenFH621N",
    "Label" : "Andersen/GMW Model  FH621-N Beta Monitor",
    "Definition" : "Andersen Instruments Model FH62I-N PM10 Beta Attenuation Monitor consisting of the following components: FH101 Vacuum Pump Assembly - FH102 Accessory Kit - FH107 Roof Flange Kit - FH125 Zero and Span PM 10 Mass Foil Calibration Kit - FH62I Beta Attenuation 19-inch Control Module - SA246b PM10Inlet (16.7 liter/min) or the louvered inlet specified in 40 CFR 50 Appendix L Figs. L-2 thru L-19 operated for 24-hour average measurements with an observing time of 60 minutes the calibration factor set to 2400 a glass fiber filter tape an automatic filter advance after each 24-hour sample period and with or without either of the following options: FH0P1 Indoor Cabinet  FH0P2 Outdoor Shelter Assembly",
    "Notation" : "andersenFH621N",
    "Status" : "Deprecated - superseded",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5" ]
  }, {
    "@id" : "andersenFH62C14",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo Andersen Series FH 62 C14 Continuous PM10 Ambient Particulate Monitor",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729669",
    "VocabularyId" : "233",
    "Identifier" : "andersenFH62C14",
    "Label" : "Thermo Andersen Series FH 62 C14 Continuous PM10 Ambient Particulate Monitor",
    "Definition" : "Thermo Andersen Series FH 62 C14 Continuous PM10 Ambient Particulate Monitor and Thermo Scientific Model 5014i Beta (5014i Beta) Continuous Ambient Particulate Monitor ” operated for 24-hour average measurements with the specified 10-micron EPA PM10inlet (or alternative louvered PM10inlet meeting 40 CFR 50 Appendix L specifications) inlet connector sample tube with heater roof flange kit mass foil kit pump kit sample filter tape with operational settings of 1000 L/h (16.67 L/min) sample flowrate daily filter change auto filter change at volumetric flow <950 L/h auto filter change at mass >1500 micrograms and factory default calculation mode settings operated with software version 1.07. Operated calibrated and serviced according to the appropriate Operator Manual",
    "Notation" : "andersenFH62C14",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5" ]
  }, {
    "@id" : "andersenFH62IN",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Andersen/GMW Model FH62I-N Beta Monitor",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729670",
    "VocabularyId" : "233",
    "Identifier" : "andersenFH62IN",
    "Label" : "Andersen/GMW Model FH62I-N Beta Monitor",
    "Definition" : "Andersen Instruments Model FH62I-N PM10 Beta Attenuation Monitor consisting of the following components: FH101 Vacuum Pump Assembly - FH102 Accessory Kit - FH107 Roof Flange Kit - FH125 Zero and Span PM 10 Mass Foil Calibration Kit - FH62I Beta Attenuation 19-inch Control Module - SA246b PM10Inlet (16.7 liter/min) or the louvered inlet specified in 40 CFR 50 Appendix L Figs. L-2 thru L-19 - operated for 24-hour average measurements with an observing time of 60 minutes the calibration factor set to 2400 a glass fiber filter tape an automatic filter advance after each 24-hour sample period and with or without either of the following options: FH0P1 Indoor Cabinet - FH0P2 Outdoor Shelter Assembly",
    "Notation" : "andersenFH62IN",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5" ]
  }, {
    "@id" : "andersenFH62IR",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo Andersen ESM FH 62 I-R",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729671",
    "VocabularyId" : "233",
    "Identifier" : "andersenFH62IR",
    "Label" : "Thermo Andersen ESM FH 62 I-R",
    "Definition" : null,
    "Notation" : "andersenFH62IR",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ "http://www.epa.gov/ttnamti1/files/ambient/criteria/reference-equivalent-methods-list.pdf" ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/4", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5" ]
  }, {
    "@id" : "andersenGPS-1-modif",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Modified Andersen GPS-1 sampler",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729672",
    "VocabularyId" : "233",
    "Identifier" : "andersenGPS-1-modif",
    "Label" : "Modified Andersen GPS-1 sampler",
    "Definition" : null,
    "Notation" : "andersenGPS-1-modif",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "andersenHVS",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Andersen/GMW generic High-Volume Air Sampler",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729673",
    "VocabularyId" : "233",
    "Identifier" : "andersenHVS",
    "Label" : "Andersen/GMW generic High-Volume Air Sampler",
    "Definition" : null,
    "Notation" : "andersenHVS",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5" ]
  }, {
    "@id" : "aurora3000",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Aurora nephelometer 3000",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729674",
    "VocabularyId" : "233",
    "Identifier" : "aurora3000",
    "Label" : "Aurora nephelometer 3000",
    "Definition" : "3 WAVELENGTH INTEGRATING NEPHELOMETERAerosol particles in the atmosphere directly influence the earth‚Äôs radiative balance by absorbing and scattering the solar radiation and indirectly by changing the clouds microphysical properties.\"",
    "Notation" : "aurora3000",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2022-12-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "bendix8101c",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Bendix/Combustion Engineering Model 8101-C Oxides of Nitrogen Analyze",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729675",
    "VocabularyId" : "233",
    "Identifier" : "bendix8101c",
    "Label" : "Bendix/Combustion Engineering Model 8101-C Oxides of Nitrogen Analyze",
    "Definition" : "Bendix or Combustion Engineering Model 8101-C Oxides of Nitrogen Analyzer operated on a 0-0.5 ppm range with a Teflon sample filter (Bendix P/N 007163) installed on the sample inlet line.",
    "Notation" : "bendix8101c",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "Definition from US EPA" ],
    "skos:example" : [ "http://www.epa.gov/ttnamti1/files/ambient/criteria/reference-equivalent-methods-list.pdf" ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8" ]
  }, {
    "@id" : "csi1600",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Columbia Scientific Industries Models 1600",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729676",
    "VocabularyId" : "233",
    "Identifier" : "csi1600",
    "Label" : "Columbia Scientific Industries Models 1600",
    "Definition" : "CSI Model 1600 Oxides of Nitrogen Analyzer operated on a 0-0.5 ppm range with a Teflon sample filter (CSI P/N M951-8023)installed on the sample inlet line",
    "Notation" : "csi1600",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "Definition from US EPA" ],
    "skos:example" : [ "http://www.epa.gov/ttnamti1/files/ambient/criteria/reference-equivalent-methods-list.pdf" ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38" ]
  }, {
    "@id" : "csi5600",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Columbia Scientific Industries Models 5600",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729677",
    "VocabularyId" : "233",
    "Identifier" : "csi5600",
    "Label" : "Columbia Scientific Industries Models 5600",
    "Definition" : "CSI Model 5600 Oxides of Nitrogen Analyzer operated on a 0-0.5 ppm range  with any signal integration time in the range of 20 to 99 seconds  with a Teflon sample filter (CSI P/N M951-8023) installed on the sample inlet line",
    "Notation" : "csi5600",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "Definition from US EPA" ],
    "skos:example" : [ "http://www.epa.gov/ttnamti1/files/ambient/criteria/reference-equivalent-methods-list.pdf" ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9" ]
  }, {
    "@id" : "dasibi",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "DASIBI",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729678",
    "VocabularyId" : "233",
    "Identifier" : "dasibi",
    "Label" : "DASIBI",
    "Definition" : null,
    "Notation" : "dasibi",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "check pollutant" ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "dasibi1003",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "DASIBI 1003 O3 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729679",
    "VocabularyId" : "233",
    "Identifier" : "dasibi1003",
    "Label" : "DASIBI 1003 O3 analyser",
    "Definition" : null,
    "Notation" : "dasibi1003",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "dasibi1003PC",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "DASIBI 1003-PC O3 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729680",
    "VocabularyId" : "233",
    "Identifier" : "dasibi1003PC",
    "Label" : "DASIBI 1003-PC O3 analyser",
    "Definition" : null,
    "Notation" : "dasibi1003PC",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "dasibi1003RS",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "DASIBI 1003-RS O3 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729681",
    "VocabularyId" : "233",
    "Identifier" : "dasibi1003RS",
    "Label" : "DASIBI 1003-RS O3 analyser",
    "Definition" : null,
    "Notation" : "dasibi1003RS",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "dasibi1008",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "DASIBI 1008 O3 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729682",
    "VocabularyId" : "233",
    "Identifier" : "dasibi1008",
    "Label" : "DASIBI 1008 O3 analyser",
    "Definition" : null,
    "Notation" : "dasibi1008",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "dasibi1008AH",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "DASIBI 1008-AH O3 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729683",
    "VocabularyId" : "233",
    "Identifier" : "dasibi1008AH",
    "Label" : "DASIBI 1008-AH O3 analyser",
    "Definition" : null,
    "Notation" : "dasibi1008AH",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "dasibi1008PC",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "DASIBI 1008-PC O3 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729684",
    "VocabularyId" : "233",
    "Identifier" : "dasibi1008PC",
    "Label" : "DASIBI 1008-PC O3 analyser",
    "Definition" : null,
    "Notation" : "dasibi1008PC",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "dasibi1008RS",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "DASIBI 1008-RS O3 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729685",
    "VocabularyId" : "233",
    "Identifier" : "dasibi1008RS",
    "Label" : "DASIBI 1008-RS O3 analyser",
    "Definition" : null,
    "Notation" : "dasibi1008RS",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "dasibi1108",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "DASIBI 1108 O3 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729686",
    "VocabularyId" : "233",
    "Identifier" : "dasibi1108",
    "Label" : "DASIBI 1108 O3 analyser",
    "Definition" : null,
    "Notation" : "dasibi1108",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "dasibi2108",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "DASIBI 2108 NOx analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729687",
    "VocabularyId" : "233",
    "Identifier" : "dasibi2108",
    "Label" : "DASIBI 2108 NOx analyser",
    "Definition" : null,
    "Notation" : "dasibi2108",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38" ]
  }, {
    "@id" : "dasibi3008",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "DASIBI 3008 CO analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729688",
    "VocabularyId" : "233",
    "Identifier" : "dasibi3008",
    "Label" : "DASIBI 3008 CO analyser",
    "Definition" : null,
    "Notation" : "dasibi3008",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "dasibi4108",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "DASIBI 4108 SO2 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729689",
    "VocabularyId" : "233",
    "Identifier" : "dasibi4108",
    "Label" : "DASIBI 4108 SO2 analyser",
    "Definition" : null,
    "Notation" : "dasibi4108",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "dasibi5014",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "DASIBI 5014",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729690",
    "VocabularyId" : "233",
    "Identifier" : "dasibi5014",
    "Label" : "DASIBI 5014",
    "Definition" : null,
    "Notation" : "dasibi5014",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "check pollutant" ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "dasibi7001",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "DASIBI 7001",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729691",
    "VocabularyId" : "233",
    "Identifier" : "dasibi7001",
    "Label" : "DASIBI 7001",
    "Definition" : null,
    "Notation" : "dasibi7001",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "check pollutant" ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "eberlineFH62-1",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "EBERLINE model FH 62-1",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729692",
    "VocabularyId" : "233",
    "Identifier" : "eberlineFH62-1",
    "Label" : "EBERLINE model FH 62-1",
    "Definition" : "Beta-absorption method PM10 analyser",
    "Notation" : "eberlineFH62-1",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "enrivoAC21M",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Environnement S.A. Model AC21M NO2 Analyzer",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729693",
    "VocabularyId" : "233",
    "Identifier" : "enrivoAC21M",
    "Label" : "Environnement S.A. Model AC21M NO2 Analyzer",
    "Definition" : null,
    "Notation" : "enrivoAC21M",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "check pollutant" ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38" ]
  }, {
    "@id" : "enrivoAC30M",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Environnement S.A. Model AC30M NO2 Analyzer",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729694",
    "VocabularyId" : "233",
    "Identifier" : "enrivoAC30M",
    "Label" : "Environnement S.A. Model AC30M NO2 Analyzer",
    "Definition" : null,
    "Notation" : "enrivoAC30M",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9" ]
  }, {
    "@id" : "enrivoAC31M",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Environnement S.A. Model AC31M NO2 Analyzer",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729695",
    "VocabularyId" : "233",
    "Identifier" : "enrivoAC31M",
    "Label" : "Environnement S.A. Model AC31M NO2 Analyzer",
    "Definition" : "Environnement S. A. Model AC31M Chemiluminescent Nitrogen Oxide Analyzer operated with a full scale range of 0 -500ppb  at any temperature in the range of 15°C to 35°C  with a 5-micron PTFE sample particulate filter  with the following software settings: Environnement S. A. Model AC31M Chemiluminescent Nitrogen Oxide Analyzer operated with a full scale range of 0 -500ppb at any temperature in the range of 15°C to 35°C with a 5-micron PTFE sample particulate filter with the following software settings: Automatic response time ON Minimum response time set to 60 seconds (RT 2) and with or without any of the following options: Internal Permeation Oven- Connection for Silica Gel Dryer- RS232-422 interface- EV3 valve- Internal Printer",
    "Notation" : "enrivoAC31M",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9" ]
  }, {
    "@id" : "enrivoAC32M",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Environnement S.A. Model AC32M NO2 Analyzer",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729696",
    "VocabularyId" : "233",
    "Identifier" : "enrivoAC32M",
    "Label" : "Environnement S.A. Model AC32M NO2 Analyzer",
    "Definition" : "Environnement S. A. Model AC32M Chemiluminescent Nitrogen Oxides Analyzer operated with a full scale range of 0 -500 ppb  at any temperature in the range of 10°C to 35°C  with a 5-micron PTFE sample particulate filter  with response time setting 11 (automatic response time)  and with or without the following option:Internal permeation oven.",
    "Notation" : "enrivoAC32M",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "Definition from US EPA" ],
    "skos:example" : [ "http://www.epa.gov/ttnamti1/files/ambient/criteria/reference-equivalent-methods-list.pdf" ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9" ]
  }, {
    "@id" : "enveaAF22E",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "ENVEA AF22E",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729697",
    "VocabularyId" : "233",
    "Identifier" : "enveaAF22E",
    "Label" : "ENVEA AF22E",
    "Definition" : "UV Fluorescence gas monitor offering excellent performances for the monitoring of SO2 in the range 0-10 ppm or 0-1 ppmEco-designed reference air quality monitor QAL1 certified by the TÜV US-EPA approved. Utilizes the standard method for the measurement of sulfur dioxides(EN 14212). With its ultra low power consumption & 24 V supply (option) the AF22e is the sole SO2 monitor on the market able to measure without being connected to the power grid.https://www.envea.global/s/emissions-en/gas-monitors-emissions-en/af22e-dilution/",
    "Notation" : "enveaAF22E",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "enveaUT3000",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "ENVEA UT3000",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729698",
    "VocabularyId" : "233",
    "Identifier" : "enveaUT3000",
    "Label" : "ENVEA UT3000",
    "Definition" : "Total Gaseous Mercury (TGM) Ultratracer. Measuring of Total Gaseous Mercury (TGM) in air and other gases",
    "Notation" : "enveaUT3000",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/4013" ]
  }, {
    "@id" : "enviroAC32E",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Environnement S.A. Model AC32E NO2 Analyzer (superseded by EnveaAC32e)",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729699",
    "VocabularyId" : "233",
    "Identifier" : "enviroAC32E",
    "Label" : "Environnement S.A. Model AC32E NO2 Analyzer (superseded by EnveaAC32e)",
    "Definition" : null,
    "Notation" : "enviroAC32E",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8" ]
  }, {
    "@id" : "enviroAF20M",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Environnement S.A. Model AF20M SO2 Analyzer",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729700",
    "VocabularyId" : "233",
    "Identifier" : "enviroAF20M",
    "Label" : "Environnement S.A. Model AF20M SO2 Analyzer",
    "Definition" : null,
    "Notation" : "enviroAF20M",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "enviroAF21M",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Environnement S.A. Model AF21M SO2 Analyzer",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729701",
    "VocabularyId" : "233",
    "Identifier" : "enviroAF21M",
    "Label" : "Environnement S.A. Model AF21M SO2 Analyzer",
    "Definition" : "Environnement S.A Model AF21M Sulfur Dioxide Analyzer operated on a range of 0-0.5 ppm with a response time coefficient setting of 01 a Teflon ilter installed in the rear - panel filter assembly and with or without any of the following options: Rack Mount/Slides RS-232-C Interface",
    "Notation" : "enviroAF21M",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "enviroAF22E",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Environnement S.A. Model AF22E SO2 Analyzer",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729702",
    "VocabularyId" : "233",
    "Identifier" : "enviroAF22E",
    "Label" : "Environnement S.A. Model AF22E SO2 Analyzer",
    "Definition" : null,
    "Notation" : "enviroAF22E",
    "Status" : "Valid",
    "StatusModifiedDate" : "2025-11-25",
    "AcceptedDate" : "2025-11-25",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "enviroAF22M",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Environnement S.A. Model AF22M SO2 Analyzer",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729703",
    "VocabularyId" : "233",
    "Identifier" : "enviroAF22M",
    "Label" : "Environnement S.A. Model AF22M SO2 Analyzer",
    "Definition" : "Environnement S.A Model AF22M UV Fluorescence Sulfur Dioxide Analyzer operated with a full scale range of 0 - 500 ppb  at any temperature in the range of 10°C to 35°C  with a 5-micron PTFE sample particulate filter  with a response time setting of 11 (Automatic response time)  with the automatic “ZERO-REF” cycle ON and set for activation every 24 hours  and with or without either of the follow ing options: Permeation oven  Rack mount slides",
    "Notation" : "enviroAF22M",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "Definition from US EPA" ],
    "skos:example" : [ "http://www.epa.gov/ttnamti1/files/ambient/criteria/reference-equivalent-methods-list.pdf" ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "enviroAS32M",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Environnement S.A. Model AS32M Nitrogen Dioxide Analyzer",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729704",
    "VocabularyId" : "233",
    "Identifier" : "enviroAS32M",
    "Label" : "Environnement S.A. Model AS32M Nitrogen Dioxide Analyzer",
    "Definition" : null,
    "Notation" : "enviroAS32M",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8" ]
  }, {
    "@id" : "enviroCO10M",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Environnement S.A. Model CO10M CO Analyzer",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729705",
    "VocabularyId" : "233",
    "Identifier" : "enviroCO10M",
    "Label" : "Environnement S.A. Model CO10M CO Analyzer",
    "Definition" : null,
    "Notation" : "enviroCO10M",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ "http://www.epa.gov/ttnamti1/files/ambient/criteria/reference-equivalent-methods-list.pdf" ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "enviroCO11M",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Environnement S.A. Model CO11M CO Analyzer",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729706",
    "VocabularyId" : "233",
    "Identifier" : "enviroCO11M",
    "Label" : "Environnement S.A. Model CO11M CO Analyzer",
    "Definition" : "Environnement S.A. Model CO11M Ambient Carbon Monoxide Analyzer operated on a full scale range of 0 - 50 ppm  at any temperature in the range of 15 °C to 35°C  with a 5-micron PTFE sample particulate filter  with the following software settings:Automatic nvironnement S.A. Model CO11M Ambient Carbon Monoxide Analyzer operated on a full scale range of 0 - 50 ppm at any temperature in the range of 15 °C to 35°C with a 5-micron PTFE sample particulate filter with the following software settings:Automatic response time ON - Minimum response time set to 40 seconds (RT 13). Automatic ZERO-REF cycle programmed every 24 hours and with or without any of the following options: RS232-422 Serial Interface - Internal Printer",
    "Notation" : "enviroCO11M",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "enviroCO12E",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Environnement S.A. Model CO12E CO Analyzer",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729707",
    "VocabularyId" : "233",
    "Identifier" : "enviroCO12E",
    "Label" : "Environnement S.A. Model CO12E CO Analyzer",
    "Definition" : null,
    "Notation" : "enviroCO12E",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "enviroCO12M",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Environnement S.A. Model CO12M CO Analyzer",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729708",
    "VocabularyId" : "233",
    "Identifier" : "enviroCO12M",
    "Label" : "Environnement S.A. Model CO12M CO Analyzer",
    "Definition" : "Environnement S.A Model CO12M Gas Filter Correlation Carbon Monoxide Analyzer operated with a full scale range of 0 - 50 ppm  at any temperature in the range of 10°C to 35°C  with a 5-micron PTFE sample particulate filter  with response time ON  and with the automatic “ZERO-REF” cycle either ON or OFF",
    "Notation" : "enviroCO12M",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "Definition from US EPA" ],
    "skos:example" : [ "http://www.epa.gov/ttnamti1/files/ambient/criteria/reference-equivalent-methods-list.pdf" ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "enviroHC51M",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Environnement-HC51M",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729709",
    "VocabularyId" : "233",
    "Identifier" : "enviroHC51M",
    "Label" : "Environnement-HC51M",
    "Definition" : "Using a proven flame ionisation detector (FID)  the analyzer HC51M measures ambient air hydrocarbons (THC  CH4  nmHC) in the range 0-1000 ppm.",
    "Notation" : "enviroHC51M",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "enviroMP101M",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Environnement S.A. Model MP101M (may be used for PM10 and PM2.5) (superseded by EnveaMP101M)",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729710",
    "VocabularyId" : "233",
    "Identifier" : "enviroMP101M",
    "Label" : "Environnement S.A. Model MP101M (may be used for PM10 and PM2.5) (superseded by EnveaMP101M)",
    "Definition" : "Environnement S. A. Model MP101M with PM10 or PM2.5 Beta Gauge Monitor ” configured with the louvered PM 10 or PM2.5 inlet specified in 40 CFR 50 Appendix L or its flat-topped predecessor version and one of the three optional temperature-regulated sampling tubes (RST)  and operated with a full scale measurement range of 0 - 0.500 mg/m3 (0 - 500 g/m3)  with the sample flow rate set to 1.00 m3/h and flow regulation set to yes   the “norms selection” set to m3(actual volume)  the “cycle” set to 24 hours  the “period” set to none  and the “counting time” set to 200 seconds",
    "Notation" : "enviroMP101M",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "Definition from US EPA" ],
    "skos:example" : [ "http://www.epa.gov/ttnamti1/files/ambient/criteria/reference-equivalent-methods-list.pdf" ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001" ]
  }, {
    "@id" : "enviroMP2.5M",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Environnement S.A. Model MP2.5M undefined",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729711",
    "VocabularyId" : "233",
    "Identifier" : "enviroMP2.5M",
    "Label" : "Environnement S.A. Model MP2.5M undefined",
    "Definition" : null,
    "Notation" : "enviroMP2.5M",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001" ]
  }, {
    "@id" : "enviroMPSI100",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Environnement S.A. Model MPSI 100",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729712",
    "VocabularyId" : "233",
    "Identifier" : "enviroMPSI100",
    "Label" : "Environnement S.A. Model MPSI 100",
    "Definition" : null,
    "Notation" : "enviroMPSI100",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5" ]
  }, {
    "@id" : "enviroO331M",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "enviroO331M",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729713",
    "VocabularyId" : "233",
    "Identifier" : "enviroO331M",
    "Label" : "enviroO331M",
    "Definition" : null,
    "Notation" : "enviroO331M",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "enviroO341M",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Environnement S.A. Model O341M UV Ozone Analyzer",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729714",
    "VocabularyId" : "233",
    "Identifier" : "enviroO341M",
    "Label" : "Environnement S.A. Model O341M UV Ozone Analyzer",
    "Definition" : "Environnement S.A. Model O341M UV Photometric Ozone Analyzer operated on a full scale range of 0 - 500 ppb at any temperature in the range of 15°C to 35°C with the response time set to 50 seconds and with or without any of the following options: Internal Ozone Generator - Span External Control - RS232 - 422 Serial Interface - Internal Printer.",
    "Notation" : "enviroO341M",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "enviroO342E",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Environnement S.A. Model O342E UV Ozone Analyzer (superseded by EnveaO342e)",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729715",
    "VocabularyId" : "233",
    "Identifier" : "enviroO342E",
    "Label" : "Environnement S.A. Model O342E UV Ozone Analyzer (superseded by EnveaO342e)",
    "Definition" : null,
    "Notation" : "enviroO342E",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "enviroO342M",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Environnement S.A. Model O342M UV Ozone Analyze",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729716",
    "VocabularyId" : "233",
    "Identifier" : "enviroO342M",
    "Label" : "Environnement S.A. Model O342M UV Ozone Analyze",
    "Definition" : "Environnement S.A Model O342M UV Photometric Ozone Analyzer ” operated with a full scale range of 0 - 500 ppb  at any temperature in the range of 10°C to 35°C  with a 5-micron PTFE sample particulate filter  with response time setting of 11 (Automatic response time)  and with or without any of the following options: c) Internal ozone generator  d) Span external control (zero/span solenoid valve).",
    "Notation" : "enviroO342M",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "Definition from US EPA" ],
    "skos:example" : [ "http://www.epa.gov/ttnamti1/files/ambient/criteria/reference-equivalent-methods-list.pdf" ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "enviroSANOA",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Environnement S.A. SANOA Multigas Longpath Monitoring System",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729717",
    "VocabularyId" : "233",
    "Identifier" : "enviroSANOA",
    "Label" : "Environnement S.A. SANOA Multigas Longpath Monitoring System",
    "Definition" : "Environnement S.A. Model SANOA Multigas Longpath Air Quality Monitoring System consisting of a receiver one or more projectors interface unit a user-provided control unit computer running the SANOA VisionAIR software and associated incidental equipment configured for measuring SO2 with the temperature control and internal calibration cell options installed operated with a measurement range of 0 to 0.5 ppm over an installed monitoring path length of between 27 and 500 meters within an ambient air temperature range of -30 to +45°C with a measurement (integrating) time of 180 seconds and with or without external temperature and barometric pressure sensors or any of the following options: external (meteo) input connection series 1M bus connection OGR type projector analog outputs.",
    "Notation" : "enviroSANOA",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "horibaAPDA350",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APDA 350 TSP analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729718",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPDA350",
    "Label" : "Horiba model APDA 350 TSP analyser",
    "Definition" : null,
    "Notation" : "horibaAPDA350",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/4" ]
  }, {
    "@id" : "horibaAPDA350E",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APDA 350E TSP analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729719",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPDA350E",
    "Label" : "Horiba model APDA 350E TSP analyser",
    "Definition" : null,
    "Notation" : "horibaAPDA350E",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/4" ]
  }, {
    "@id" : "horibaAPDA351",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APDA 351 TSP analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729720",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPDA351",
    "Label" : "Horiba model APDA 351 TSP analyser",
    "Definition" : null,
    "Notation" : "horibaAPDA351",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/4" ]
  }, {
    "@id" : "horibaAPDA351E",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APDA 351E TSP analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729721",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPDA351E",
    "Label" : "Horiba model APDA 351E TSP analyser",
    "Definition" : null,
    "Notation" : "horibaAPDA351E",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/4" ]
  }, {
    "@id" : "horibaAPDA371",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APDA 371",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729722",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPDA371",
    "Label" : "Horiba model APDA 371",
    "Definition" : null,
    "Notation" : "horibaAPDA371",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5" ]
  }, {
    "@id" : "horibaAPDA372",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APDA 372",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729723",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPDA372",
    "Label" : "Horiba model APDA 372",
    "Definition" : "Horiba model APDA 372",
    "Notation" : "horibaAPDA372",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6002", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5" ]
  }, {
    "@id" : "horibaAPHA350E",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APHA 360E hydrocarbons analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729724",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPHA350E",
    "Label" : "Horiba model APHA 360E hydrocarbons analyser",
    "Definition" : null,
    "Notation" : "horibaAPHA350E",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ "hydrocarbons" ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "horibaAPHA360",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APHA 360 hydrocarbons analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729725",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPHA360",
    "Label" : "Horiba model APHA 360 hydrocarbons analyser",
    "Definition" : null,
    "Notation" : "horibaAPHA360",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ "hydrocarbons" ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "horibaAPHA370",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APHA 370 hydrocarbons analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729726",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPHA370",
    "Label" : "Horiba model APHA 370 hydrocarbons analyser",
    "Definition" : null,
    "Notation" : "horibaAPHA370",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "horibaAPMA300",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APMA 300 CO analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729727",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPMA300",
    "Label" : "Horiba model APMA 300 CO analyser",
    "Definition" : null,
    "Notation" : "horibaAPMA300",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "horibaAPMA300E",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APMA 300E CO analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729728",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPMA300E",
    "Label" : "Horiba model APMA 300E CO analyser",
    "Definition" : null,
    "Notation" : "horibaAPMA300E",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "horibaAPMA350",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APMA 350 CO analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729729",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPMA350",
    "Label" : "Horiba model APMA 350 CO analyser",
    "Definition" : null,
    "Notation" : "horibaAPMA350",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "horibaAPMA350E",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APMA 350E CO analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729730",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPMA350E",
    "Label" : "Horiba model APMA 350E CO analyser",
    "Definition" : null,
    "Notation" : "horibaAPMA350E",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "horibaAPMA360",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APMA 360 CO analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729731",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPMA360",
    "Label" : "Horiba model APMA 360 CO analyser",
    "Definition" : null,
    "Notation" : "horibaAPMA360",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "horibaAPMA360CE",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APMA 360CE CO analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729732",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPMA360CE",
    "Label" : "Horiba model APMA 360CE CO analyser",
    "Definition" : null,
    "Notation" : "horibaAPMA360CE",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "horibaAPMA360E",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APMA 360E CO analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729733",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPMA360E",
    "Label" : "Horiba model APMA 360E CO analyser",
    "Definition" : null,
    "Notation" : "horibaAPMA360E",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "horibaAPMA370",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APMA 370 CO analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729734",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPMA370",
    "Label" : "Horiba model APMA 370 CO analyser",
    "Definition" : null,
    "Notation" : "horibaAPMA370",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "horibaAPMA380",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APMA 380 CO analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729735",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPMA380",
    "Label" : "Horiba model APMA 380 CO analyser",
    "Definition" : null,
    "Notation" : "horibaAPMA380",
    "Status" : "Valid",
    "StatusModifiedDate" : "2025-11-25",
    "AcceptedDate" : "2025-11-25",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "horibaAPNA300",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APNA 300 NOx analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729736",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPNA300",
    "Label" : "Horiba model APNA 300 NOx analyser",
    "Definition" : null,
    "Notation" : "horibaAPNA300",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9" ]
  }, {
    "@id" : "horibaAPNA300E",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APNA 300E NOx analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729737",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPNA300E",
    "Label" : "Horiba model APNA 300E NOx analyser",
    "Definition" : null,
    "Notation" : "horibaAPNA300E",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8" ]
  }, {
    "@id" : "horibaAPNA350",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APNA 350 NOx analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729738",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPNA350",
    "Label" : "Horiba model APNA 350 NOx analyser",
    "Definition" : null,
    "Notation" : "horibaAPNA350",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38" ]
  }, {
    "@id" : "horibaAPNA350E",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APNA 350E NOx analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729739",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPNA350E",
    "Label" : "Horiba model APNA 350E NOx analyser",
    "Definition" : null,
    "Notation" : "horibaAPNA350E",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38" ]
  }, {
    "@id" : "horibaAPNA360",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APNA 360 NOx analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729740",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPNA360",
    "Label" : "Horiba model APNA 360 NOx analyser",
    "Definition" : null,
    "Notation" : "horibaAPNA360",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9" ]
  }, {
    "@id" : "horibaAPNA360E",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APNA 360E NOx analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729741",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPNA360E",
    "Label" : "Horiba model APNA 360E NOx analyser",
    "Definition" : null,
    "Notation" : "horibaAPNA360E",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9" ]
  }, {
    "@id" : "horibaAPNA370",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APNA 370 NOx analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729742",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPNA370",
    "Label" : "Horiba model APNA 370 NOx analyser",
    "Definition" : null,
    "Notation" : "horibaAPNA370",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38" ]
  }, {
    "@id" : "horibaAPNA380",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APNA 380 NOx analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729743",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPNA380",
    "Label" : "Horiba model APNA 380 NOx analyser",
    "Definition" : null,
    "Notation" : "horibaAPNA380",
    "Status" : "Valid",
    "StatusModifiedDate" : "2025-11-25",
    "AcceptedDate" : "2025-11-25",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9" ]
  }, {
    "@id" : "horibaAPOA300",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APOA 300 O3 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729744",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPOA300",
    "Label" : "Horiba model APOA 300 O3 analyser",
    "Definition" : null,
    "Notation" : "horibaAPOA300",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "horibaAPOA350",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APOA 350 O3 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729745",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPOA350",
    "Label" : "Horiba model APOA 350 O3 analyser",
    "Definition" : null,
    "Notation" : "horibaAPOA350",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "horibaAPOA350E",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APOA 350E O3 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729746",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPOA350E",
    "Label" : "Horiba model APOA 350E O3 analyser",
    "Definition" : null,
    "Notation" : "horibaAPOA350E",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "horibaAPOA360",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APOA 360 O3 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729747",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPOA360",
    "Label" : "Horiba model APOA 360 O3 analyser",
    "Definition" : null,
    "Notation" : "horibaAPOA360",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "horibaAPOA360E",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APOA 350E O3 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729748",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPOA360E",
    "Label" : "Horiba model APOA 350E O3 analyser",
    "Definition" : null,
    "Notation" : "horibaAPOA360E",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "horibaAPOA370",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APOA 370 O3 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729749",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPOA370",
    "Label" : "Horiba model APOA 370 O3 analyser",
    "Definition" : null,
    "Notation" : "horibaAPOA370",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "horibaAPSA300",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APSA 300 SO2 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729750",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPSA300",
    "Label" : "Horiba model APSA 300 SO2 analyser",
    "Definition" : null,
    "Notation" : "horibaAPSA300",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "horibaAPSA350",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APSA 350 SO2 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729751",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPSA350",
    "Label" : "Horiba model APSA 350 SO2 analyser",
    "Definition" : null,
    "Notation" : "horibaAPSA350",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "horibaAPSA350E",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APSA 350E SO2 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729752",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPSA350E",
    "Label" : "Horiba model APSA 350E SO2 analyser",
    "Definition" : null,
    "Notation" : "horibaAPSA350E",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "horibaAPSA360",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APSA 360 SO2 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729753",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPSA360",
    "Label" : "Horiba model APSA 360 SO2 analyser",
    "Definition" : null,
    "Notation" : "horibaAPSA360",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "horibaAPSA360A",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APSA 360A SO2 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729754",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPSA360A",
    "Label" : "Horiba model APSA 360A SO2 analyser",
    "Definition" : null,
    "Notation" : "horibaAPSA360A",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "horibaAPSA360E",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APSA 360E SO2 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729755",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPSA360E",
    "Label" : "Horiba model APSA 360E SO2 analyser",
    "Definition" : null,
    "Notation" : "horibaAPSA360E",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "horibaAPSA370",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APSA 370 SO2 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729756",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPSA370",
    "Label" : "Horiba model APSA 370 SO2 analyser",
    "Definition" : null,
    "Notation" : "horibaAPSA370",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/11", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "horibaFH621R",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "ONLY USED IN ONE STATION IN RS",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729757",
    "VocabularyId" : "233",
    "Identifier" : "horibaFH621R",
    "Label" : "ONLY USED IN ONE STATION IN RS",
    "Definition" : null,
    "Notation" : "horibaFH621R",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "ONLY USED IN ONE STATION IN RS" ],
    "skos:example" : [ "http://www.doiserbia.nb.rs/img/doi/1451-9372/2008/1451-93720801005J.pdf" ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5" ]
  }, {
    "@id" : "kimoto168s",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "KIMOTO 168s",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729758",
    "VocabularyId" : "233",
    "Identifier" : "kimoto168s",
    "Label" : "KIMOTO 168s",
    "Definition" : null,
    "Notation" : "kimoto168s",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5" ]
  }, {
    "@id" : "marga",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Marga",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729759",
    "VocabularyId" : "233",
    "Identifier" : "marga",
    "Label" : "Marga",
    "Definition" : null,
    "Notation" : "marga",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "mcv30ql",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "MCV 30-QL",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729760",
    "VocabularyId" : "233",
    "Identifier" : "mcv30ql",
    "Label" : "MCV 30-QL",
    "Definition" : null,
    "Notation" : "mcv30ql",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "check pollutant" ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "mcv48auv",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "MCV 48-AUV",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729761",
    "VocabularyId" : "233",
    "Identifier" : "mcv48auv",
    "Label" : "MCV 48-AUV",
    "Definition" : null,
    "Notation" : "mcv48auv",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "check pollutant" ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "mcv64fuv",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "MCV 64-FUV",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729762",
    "VocabularyId" : "233",
    "Identifier" : "mcv64fuv",
    "Label" : "MCV 64-FUV",
    "Definition" : null,
    "Notation" : "mcv64fuv",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "check pollutant" ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "mcvCAV-AMSb",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "MCV CAV-A/MSb Captador d'Alt Volum Seqüencial",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729763",
    "VocabularyId" : "233",
    "Identifier" : "mcvCAV-AMSb",
    "Label" : "MCV CAV-A/MSb Captador d'Alt Volum Seqüencial",
    "Definition" : null,
    "Notation" : "mcvCAV-AMSb",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ "http://www.mcvsa.com/Productes/Atm%C3%B3sfera/CaptadordealtovolumensecuencialMCVCAVAMSb/tabid/139/Default.aspx" ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001" ]
  }, {
    "@id" : "mcvCAV-Amb",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "MCV CAV-A/mb Captador d'Alt Volum",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729764",
    "VocabularyId" : "233",
    "Identifier" : "mcvCAV-Amb",
    "Label" : "MCV CAV-A/mb Captador d'Alt Volum",
    "Definition" : null,
    "Notation" : "mcvCAV-Amb",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ "http://www.mcvsa.com/Productes/Atm%C3%B3sfera/CaptadordealtovolumenMCVCAVAmb/tabid/114/Default.aspx" ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001" ]
  }, {
    "@id" : "meloySA700",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Meloy Model SA 700 Fluorescence Sulfur Dioxide Analyze",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729765",
    "VocabularyId" : "233",
    "Identifier" : "meloySA700",
    "Label" : "Meloy Model SA 700 Fluorescence Sulfur Dioxide Analyze",
    "Definition" : "Meloy Model SA 700 Fluorescence Sulfur Dioxide Analyzeroperated on the 0-250 ppb1 the 0-500 ppb or the 0-1000 ppb range with a time constant switch position of either 2 or 3.The analyzer may be operated at temperatures between 20°C and 30°C and at line voltages between 105 and 130 volts with or without any of the following options: FS-1 Current Output - FS-2 Rack Mount Conversion - FS-2A Rack Mount Conversion - FS-2B Rack Mount Conversion - FS-3 Front Panel Mounted Digital Meter - FS-5 Auto/Manual Zero/Span With Status - FS-6Remote/Manual Zero/Span With Status - FS-7 Auto Zero Adjust. voltages between 105 and 130 volts  with or without any of the following options: FS-1 Current Output",
    "Notation" : "meloySA700",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "multigasMMS",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Multi-gas Micro Monitoring station (MMS) Portable version",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729766",
    "VocabularyId" : "233",
    "Identifier" : "multigasMMS",
    "Label" : "Multi-gas Micro Monitoring station (MMS) Portable version",
    "Definition" : null,
    "Notation" : "multigasMMS",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ "multiple" ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "opsisAR500",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Opsis AR500 Open path monitor",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729767",
    "VocabularyId" : "233",
    "Identifier" : "opsisAR500",
    "Label" : "Opsis AR500 Open path monitor",
    "Definition" : null,
    "Notation" : "opsisAR500",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "opsisAR500-ER110",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Opsis AR500 Open path monitor with ER 110",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729768",
    "VocabularyId" : "233",
    "Identifier" : "opsisAR500-ER110",
    "Label" : "Opsis AR500 Open path monitor with ER 110",
    "Definition" : null,
    "Notation" : "opsisAR500-ER110",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/20", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "opsisAR500-ER120",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Opsis AR500 Open path monitor with ER 120",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729769",
    "VocabularyId" : "233",
    "Identifier" : "opsisAR500-ER120",
    "Label" : "Opsis AR500 Open path monitor with ER 120",
    "Definition" : null,
    "Notation" : "opsisAR500-ER120",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/20", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "opsisAR500-ER150",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Opsis AR500 Open path monitor with ER 150",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729770",
    "VocabularyId" : "233",
    "Identifier" : "opsisAR500-ER150",
    "Label" : "Opsis AR500 Open path monitor with ER 150",
    "Definition" : null,
    "Notation" : "opsisAR500-ER150",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/20", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/21", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "opsisSM200",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Opsis SM200 Particulate Analyser with PM2.5 & PM10 Heads",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729771",
    "VocabularyId" : "233",
    "Identifier" : "opsisSM200",
    "Label" : "Opsis SM200 Particulate Analyser with PM2.5 & PM10 Heads",
    "Definition" : null,
    "Notation" : "opsisSM200",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001" ]
  }, {
    "@id" : "osiris",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Osiris Turnkey Instruments",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729772",
    "VocabularyId" : "233",
    "Identifier" : "osiris",
    "Label" : "Osiris Turnkey Instruments",
    "Definition" : "Osiris air monitoring device measures airborne particles (TSP  PM10  PM2.5 and PM1). MCERTS certified for PM10",
    "Notation" : "osiris",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "other",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Other",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729773",
    "VocabularyId" : "233",
    "Identifier" : "other",
    "Label" : "Other",
    "Definition" : null,
    "Notation" : "other",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "perkinelmerC500",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Perkin Elmer Clarus 500",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729774",
    "VocabularyId" : "233",
    "Identifier" : "perkinelmerC500",
    "Label" : "Perkin Elmer Clarus 500",
    "Definition" : "Perkin Elmer Clarus 500",
    "Notation" : "perkinelmerC500",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "perkinelmerTurbomatrixDesorber",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Perking Elmer Turbomatrix Desorber",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729775",
    "VocabularyId" : "233",
    "Identifier" : "perkinelmerTurbomatrixDesorber",
    "Label" : "Perking Elmer Turbomatrix Desorber",
    "Definition" : "Perking Elmer Turbomatrix Desorber",
    "Notation" : "perkinelmerTurbomatrixDesorber",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "philipsK50031",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "PHILIPS K50031 Chromatographic Analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729776",
    "VocabularyId" : "233",
    "Identifier" : "philipsK50031",
    "Label" : "PHILIPS K50031 Chromatographic Analyser",
    "Definition" : null,
    "Notation" : "philipsK50031",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ "NM-VOC & CH4" ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "philipsK50033",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "PHILIPS K50033 API 100E",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729777",
    "VocabularyId" : "233",
    "Identifier" : "philipsK50033",
    "Label" : "PHILIPS K50033 API 100E",
    "Definition" : null,
    "Notation" : "philipsK50033",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ "http://fbd.beun.edu.tr/index.php/zkufbd/article/download/53/100" ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "philipsK50034",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "PHILIPS K50034 API 200A",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729778",
    "VocabularyId" : "233",
    "Identifier" : "philipsK50034",
    "Label" : "PHILIPS K50034 API 200A",
    "Definition" : null,
    "Notation" : "philipsK50034",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ "http://fbd.beun.edu.tr/index.php/zkufbd/article/download/53/100" ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8" ]
  }, {
    "@id" : "philipsK50093",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "PHILIPS K50093 API 300A",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729779",
    "VocabularyId" : "233",
    "Identifier" : "philipsK50093",
    "Label" : "PHILIPS K50093 API 300A",
    "Definition" : null,
    "Notation" : "philipsK50093",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ "http://fbd.beun.edu.tr/index.php/zkufbd/article/download/53/100" ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "philipsK50094",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "PHILIPS K50094 API 400",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729780",
    "VocabularyId" : "233",
    "Identifier" : "philipsK50094",
    "Label" : "PHILIPS K50094 API 400",
    "Definition" : null,
    "Notation" : "philipsK50094",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ "http://fbd.beun.edu.tr/index.php/zkufbd/article/download/53/100" ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "philipsK50102",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "PHILIPS K50102 NO",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729781",
    "VocabularyId" : "233",
    "Identifier" : "philipsK50102",
    "Label" : "PHILIPS K50102 NO",
    "Definition" : null,
    "Notation" : "philipsK50102",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ "http://www.brace.sinanet.apat.it/" ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8" ]
  }, {
    "@id" : "philipsK50109",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "PHILIPS K50109/00 Gas Filter Correlation CO analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729782",
    "VocabularyId" : "233",
    "Identifier" : "philipsK50109",
    "Label" : "PHILIPS K50109/00 Gas Filter Correlation CO analyser",
    "Definition" : null,
    "Notation" : "philipsK50109",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ "http://www.docstoc.com/docs/145715957/ABC_EAREX07_instruments" ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "philipsK50110",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "PHILIPS K50110/00 UV Photometric O3 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729783",
    "VocabularyId" : "233",
    "Identifier" : "philipsK50110",
    "Label" : "PHILIPS K50110/00 UV Photometric O3 analyser",
    "Definition" : null,
    "Notation" : "philipsK50110",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ "http://www.docstoc.com/docs/145715957/ABC_EAREX07_instruments" ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "philipsK50129",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "PHILIPS K50129 unknown",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729784",
    "VocabularyId" : "233",
    "Identifier" : "philipsK50129",
    "Label" : "PHILIPS K50129 unknown",
    "Definition" : null,
    "Notation" : "philipsK50129",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "check pollutant" ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "philipsK50130",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "PHILIPS K50130 unknown",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729785",
    "VocabularyId" : "233",
    "Identifier" : "philipsK50130",
    "Label" : "PHILIPS K50130 unknown",
    "Definition" : null,
    "Notation" : "philipsK50130",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "check pollutant" ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "philipsK50206",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "PHILIPS K50206/00 Pulsed Fluorescence SO2 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729786",
    "VocabularyId" : "233",
    "Identifier" : "philipsK50206",
    "Label" : "PHILIPS K50206/00 Pulsed Fluorescence SO2 analyser",
    "Definition" : null,
    "Notation" : "philipsK50206",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ "http://www.docstoc.com/docs/145715957/ABC_EAREX07_instruments" ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "philipsK50235",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "PHILIPS K50235/00 NO-NOx-NO2 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729787",
    "VocabularyId" : "233",
    "Identifier" : "philipsK50235",
    "Label" : "PHILIPS K50235/00 NO-NOx-NO2 analyser",
    "Definition" : null,
    "Notation" : "philipsK50235",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ "http://www.arpa.emr.it/cms3/documenti/_cerca_doc/aria/rimini/rn_valloni_tesi_laurea_mar2010.pdf" ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9" ]
  }, {
    "@id" : "philipsPW9700",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Philips PW 9700",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729788",
    "VocabularyId" : "233",
    "Identifier" : "philipsPW9700",
    "Label" : "Philips PW 9700",
    "Definition" : "Philips PW 9700",
    "Notation" : "Philips PW 9700",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "philipsPW9755",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "PHILIPS PW9755/00 SO2 Analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729789",
    "VocabularyId" : "233",
    "Identifier" : "philipsPW9755",
    "Label" : "PHILIPS PW9755/00 SO2 Analyser",
    "Definition" : null,
    "Notation" : "philipsPW9755",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "philipsPW9762",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "PHILIPS PW9762/00 NO/NO2/NOX Analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729790",
    "VocabularyId" : "233",
    "Identifier" : "philipsPW9762",
    "Label" : "PHILIPS PW9762/00 NO/NO2/NOX Analyser",
    "Definition" : null,
    "Notation" : "philipsPW9762",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ "http://www.epa.gov/ttnamti1/files/ambient/criteria/reference-equivalent-methods-list.pdf" ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38" ]
  }, {
    "@id" : "philipsPW9771",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "philipsPW9771",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729791",
    "VocabularyId" : "233",
    "Identifier" : "philipsPW9771",
    "Label" : "philipsPW9771",
    "Definition" : "philipsPW9771",
    "Notation" : "philipsPW9771",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-09-02",
    "AcceptedDate" : "2024-09-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "philipsPW9775",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "PHILIPS PW9775/00 CO Analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729792",
    "VocabularyId" : "233",
    "Identifier" : "philipsPW9775",
    "Label" : "PHILIPS PW9775/00 CO Analyser",
    "Definition" : "PHILIPS PW9775/00 CO Analyser",
    "Notation" : "philipsPW9775",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-07",
    "AcceptedDate" : "2024-08-07",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "picarroG2103",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Picarro G2103",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729793",
    "VocabularyId" : "233",
    "Identifier" : "picarroG2103",
    "Label" : "Picarro G2103",
    "Definition" : "Picarro G2103 (used for NH3 measurement)",
    "Notation" : "picarroG2103",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/35" ]
  }, {
    "@id" : "picarroG2302",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Picarro G2302",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729794",
    "VocabularyId" : "233",
    "Identifier" : "picarroG2302",
    "Label" : "Picarro G2302",
    "Definition" : "Picarro G2302 (used for CO measurement)",
    "Notation" : "picarroG2302",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "picarroG2303",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Picarro G2303",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729795",
    "VocabularyId" : "233",
    "Identifier" : "picarroG2303",
    "Label" : "Picarro G2303",
    "Definition" : "Picarro G2303 (used for CO measurement)",
    "Notation" : "picarroG2303",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "serinus40",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "serinus 40 Nox",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729796",
    "VocabularyId" : "233",
    "Identifier" : "serinus40",
    "Label" : "serinus 40 Nox",
    "Definition" : null,
    "Notation" : "serinus40",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "not from OPSIS" ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8" ]
  }, {
    "@id" : "serinus40NH3",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "serinus 40 with NH3 converter",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729797",
    "VocabularyId" : "233",
    "Identifier" : "serinus40NH3",
    "Label" : "serinus 40 with NH3 converter",
    "Definition" : "Ecotech serinus 40 used for NOx-NO2-NO modified to measure NOH3 (including a converter)",
    "Notation" : "serinus40NH3",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/35" ]
  }, {
    "@id" : "serinus51",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "ECOTECH SERINUS 51",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729798",
    "VocabularyId" : "233",
    "Identifier" : "serinus51",
    "Label" : "ECOTECH SERINUS 51",
    "Definition" : "The Serinus 51 H2S/SO2 instruments can integrate seamlessly into continuous monitoring networks and can sequentially measure H2S and then SO2",
    "Notation" : "serinus51",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "sunsetTOCA",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "EC/OC measurements Sunset Laboratory Inc Thermal / Optical Carbon Analyser (near-real time)",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729799",
    "VocabularyId" : "233",
    "Identifier" : "sunsetTOCA",
    "Label" : "EC/OC measurements Sunset Laboratory Inc Thermal / Optical Carbon Analyser (near-real time)",
    "Definition" : "EC/OC measurements Sunset Laboratory Inc Thermal / Optical Carbon Analyser - operated near real time",
    "Notation" : "sunsetTOCA",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "tecanCLD502",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Tecan CLD502",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729800",
    "VocabularyId" : "233",
    "Identifier" : "tecanCLD502",
    "Label" : "Tecan CLD502",
    "Definition" : null,
    "Notation" : "tecanCLD502",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "tekran1130",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Tekran mercury analyser 1130",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729801",
    "VocabularyId" : "233",
    "Identifier" : "tekran1130",
    "Label" : "Tekran mercury analyser 1130",
    "Definition" : "Tekran mercury analyser 1130",
    "Notation" : "tekran1130",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "tekran1135",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Tekran mercury analyser 1135",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729802",
    "VocabularyId" : "233",
    "Identifier" : "tekran1135",
    "Label" : "Tekran mercury analyser 1135",
    "Definition" : "Tekran mercury analyser 1135",
    "Notation" : "tekran1135",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "tekran2537A",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Tekran mercury analyser 2537A",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729803",
    "VocabularyId" : "233",
    "Identifier" : "tekran2537A",
    "Label" : "Tekran mercury analyser 2537A",
    "Definition" : "Tekran mercury analyser 2537A. Elemental mercury is sampled by placing the 1130 before the main 2537A instrument. The respective constituents are sampled from the air using either the 1130 add-on for reactive gaseous mercury or the 1135 add-on for particulate bound mercury.",
    "Notation" : "tekran2537A",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "tekran2537B",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Tekran mercury analyser 2537B",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729804",
    "VocabularyId" : "233",
    "Identifier" : "tekran2537B",
    "Label" : "Tekran mercury analyser 2537B",
    "Definition" : "Tekran mercury analyser 2537B",
    "Notation" : "tekran2537B",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "tekran2537X",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Tekran mercury analyser 2537X",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729805",
    "VocabularyId" : "233",
    "Identifier" : "tekran2537X",
    "Label" : "Tekran mercury analyser 2537X",
    "Definition" : "Tekran mercury analyser 2537X",
    "Notation" : "tekran2537X",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "thermo14B",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo model 14B chemiluminescence NO-NO2-Nox",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729806",
    "VocabularyId" : "233",
    "Identifier" : "thermo14B",
    "Label" : "Thermo model 14B chemiluminescence NO-NO2-Nox",
    "Definition" : null,
    "Notation" : "thermo14B",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38" ]
  }, {
    "@id" : "thermo14B-E",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo model 14B/E chemiluminescence NO-NO2-Nox",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729807",
    "VocabularyId" : "233",
    "Identifier" : "thermo14B-E",
    "Label" : "Thermo model 14B/E chemiluminescence NO-NO2-Nox",
    "Definition" : null,
    "Notation" : "thermo14B-E",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9" ]
  }, {
    "@id" : "thermo14BE",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo model 14B/E chemiluminescence NO-NO2-Nox",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729808",
    "VocabularyId" : "233",
    "Identifier" : "thermo14BE",
    "Label" : "Thermo model 14B/E chemiluminescence NO-NO2-Nox",
    "Definition" : null,
    "Notation" : "thermo14BE",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9" ]
  }, {
    "@id" : "thermo41h",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "thermo41h",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729809",
    "VocabularyId" : "233",
    "Identifier" : "thermo41h",
    "Label" : "thermo41h",
    "Definition" : "Gas Filter Correlation CO2 Analyzer 115V-AC",
    "Notation" : "thermo41h",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-12-12",
    "AcceptedDate" : "2024-12-12",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/71" ]
  }, {
    "@id" : "thermo42",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo model 42 NO/Nox analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729810",
    "VocabularyId" : "233",
    "Identifier" : "thermo42",
    "Label" : "Thermo model 42 NO/Nox analyser",
    "Definition" : null,
    "Notation" : "thermo42",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "check", "specific model undetermined" ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9" ]
  }, {
    "@id" : "thermo42c",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo model 42c NO/Nox analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729811",
    "VocabularyId" : "233",
    "Identifier" : "thermo42c",
    "Label" : "Thermo model 42c NO/Nox analyser",
    "Definition" : null,
    "Notation" : "thermo42c",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ "http://www.thermo.com/eThermo/CMA/PDFs/Various/156File_17809.pdf" ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38" ]
  }, {
    "@id" : "thermo42c-TL",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo model 42C-TL (Trace level Nox)",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729812",
    "VocabularyId" : "233",
    "Identifier" : "thermo42c-TL",
    "Label" : "Thermo model 42C-TL (Trace level Nox)",
    "Definition" : null,
    "Notation" : "thermo42c-TL",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "does this exist?" ],
    "skos:example" : [ "https://www.thermo.com/eThermo/CMA/PDFs/Product/productPDF_20985.pdf" ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38" ]
  }, {
    "@id" : "thermo42i",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo model 42i NO/Nox analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729813",
    "VocabularyId" : "233",
    "Identifier" : "thermo42i",
    "Label" : "Thermo model 42i NO/Nox analyser",
    "Definition" : null,
    "Notation" : "thermo42i",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38" ]
  }, {
    "@id" : "thermo42i-BL",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo model 42i NO/NOx analyser - blue light",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729814",
    "VocabularyId" : "233",
    "Identifier" : "thermo42i-BL",
    "Label" : "Thermo model 42i NO/NOx analyser - blue light",
    "Definition" : null,
    "Notation" : "thermo42i-BL",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9" ]
  }, {
    "@id" : "thermo42i-TL",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo model 42i-TL (Trace level Nox)",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729815",
    "VocabularyId" : "233",
    "Identifier" : "thermo42i-TL",
    "Label" : "Thermo model 42i-TL (Trace level Nox)",
    "Definition" : null,
    "Notation" : "thermo42i-TL",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ "https://www.thermo.com/eThermo/CMA/PDFs/Product/productPDF_30698.pdf" ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38" ]
  }, {
    "@id" : "thermo42s",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo model 42s NO/Nox analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729816",
    "VocabularyId" : "233",
    "Identifier" : "thermo42s",
    "Label" : "Thermo model 42s NO/Nox analyser",
    "Definition" : null,
    "Notation" : "thermo42s",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38" ]
  }, {
    "@id" : "thermo42w",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo model 42w NO/Nox analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729817",
    "VocabularyId" : "233",
    "Identifier" : "thermo42w",
    "Label" : "Thermo model 42w NO/Nox analyser",
    "Definition" : null,
    "Notation" : "thermo42w",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/8", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/9", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/38" ]
  }, {
    "@id" : "thermo43",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo model 43 SO2 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729818",
    "VocabularyId" : "233",
    "Identifier" : "thermo43",
    "Label" : "Thermo model 43 SO2 analyser",
    "Definition" : null,
    "Notation" : "thermo43",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "specific model undetermined" ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "thermo43CTL",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo model 43c-TL SO2 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729819",
    "VocabularyId" : "233",
    "Identifier" : "thermo43CTL",
    "Label" : "Thermo model 43c-TL SO2 analyser",
    "Definition" : null,
    "Notation" : "thermo43CTL",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ "https://www.thermo.com/eThermo/CMA/PDFs/Product/productPDF_30540.pdf" ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "thermo43a",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo model 43a SO2 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729820",
    "VocabularyId" : "233",
    "Identifier" : "thermo43a",
    "Label" : "Thermo model 43a SO2 analyser",
    "Definition" : null,
    "Notation" : "thermo43a",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "thermo43b",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo model 43b SO2 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729821",
    "VocabularyId" : "233",
    "Identifier" : "thermo43b",
    "Label" : "Thermo model 43b SO2 analyser",
    "Definition" : null,
    "Notation" : "thermo43b",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "thermo43bs",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo model 43bs SO2 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729822",
    "VocabularyId" : "233",
    "Identifier" : "thermo43bs",
    "Label" : "Thermo model 43bs SO2 analyser",
    "Definition" : null,
    "Notation" : "thermo43bs",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "thermo43c",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo model 43c SO2 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729823",
    "VocabularyId" : "233",
    "Identifier" : "thermo43c",
    "Label" : "Thermo model 43c SO2 analyser",
    "Definition" : null,
    "Notation" : "thermo43c",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "thermo43h",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo model 43h pulsed fluorescence SO2 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729824",
    "VocabularyId" : "233",
    "Identifier" : "thermo43h",
    "Label" : "Thermo model 43h pulsed fluorescence SO2 analyser",
    "Definition" : null,
    "Notation" : "thermo43h",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "thermo43i",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo model 43i SO2 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729825",
    "VocabularyId" : "233",
    "Identifier" : "thermo43i",
    "Label" : "Thermo model 43i SO2 analyser",
    "Definition" : null,
    "Notation" : "thermo43i",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ "https://static.thermoscientific.com/images/D19736~.pdf" ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "thermo43i-TLE",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo model 43i-TLE (Enhanced Trace Level)",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729826",
    "VocabularyId" : "233",
    "Identifier" : "thermo43i-TLE",
    "Label" : "Thermo model 43i-TLE (Enhanced Trace Level)",
    "Definition" : null,
    "Notation" : "thermo43i-TLE",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ "http://www.thermo.com/eThermo/CMA/PDFs/Product/productPDF_20982.pdf" ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "thermo43s",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo model 43s SO2 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729827",
    "VocabularyId" : "233",
    "Identifier" : "thermo43s",
    "Label" : "Thermo model 43s SO2 analyser",
    "Definition" : null,
    "Notation" : "thermo43s",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "check" ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "thermo43w",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo model 43w SO2 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729828",
    "VocabularyId" : "233",
    "Identifier" : "thermo43w",
    "Label" : "Thermo model 43w SO2 analyser",
    "Definition" : null,
    "Notation" : "thermo43w",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "thermo48",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo model 48 CO analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729829",
    "VocabularyId" : "233",
    "Identifier" : "thermo48",
    "Label" : "Thermo model 48 CO analyser",
    "Definition" : null,
    "Notation" : "thermo48",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "thermo48-GFC",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo model 48 CO analyser (gas filter correlation)",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729830",
    "VocabularyId" : "233",
    "Identifier" : "thermo48-GFC",
    "Label" : "Thermo model 48 CO analyser (gas filter correlation)",
    "Definition" : null,
    "Notation" : "thermo48-GFC",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "thermo48c",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo model 48c CO analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729831",
    "VocabularyId" : "233",
    "Identifier" : "thermo48c",
    "Label" : "Thermo model 48c CO analyser",
    "Definition" : null,
    "Notation" : "thermo48c",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "thermo48i",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo model 48i CO analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729832",
    "VocabularyId" : "233",
    "Identifier" : "thermo48i",
    "Label" : "Thermo model 48i CO analyser",
    "Definition" : null,
    "Notation" : "thermo48i",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "thermo48i-TLE",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo model 48i-TLE (Enhanced Trace Level)",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729833",
    "VocabularyId" : "233",
    "Identifier" : "thermo48i-TLE",
    "Label" : "Thermo model 48i-TLE (Enhanced Trace Level)",
    "Definition" : null,
    "Notation" : "thermo48i-TLE",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "thermo48w",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo model 48w CO analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729834",
    "VocabularyId" : "233",
    "Identifier" : "thermo48w",
    "Label" : "Thermo model 48w CO analyser",
    "Definition" : null,
    "Notation" : "thermo48w",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/10" ]
  }, {
    "@id" : "thermo49",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo model 49 O3 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729835",
    "VocabularyId" : "233",
    "Identifier" : "thermo49",
    "Label" : "Thermo model 49 O3 analyser",
    "Definition" : null,
    "Notation" : "thermo49",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "thermo49c",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo model 49c O3 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729836",
    "VocabularyId" : "233",
    "Identifier" : "thermo49c",
    "Label" : "Thermo model 49c O3 analyser",
    "Definition" : null,
    "Notation" : "thermo49c",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "thermo49cps",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo 49 CPS Ozone Primary Standard",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729837",
    "VocabularyId" : "233",
    "Identifier" : "thermo49cps",
    "Label" : "Thermo 49 CPS Ozone Primary Standard",
    "Definition" : null,
    "Notation" : "thermo49cps",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "This is a reference photomer  not an analyser", "Thermo 49 CPS Ozone Primary Standard" ],
    "skos:example" : [ "http://rental.cleanair.com/thermo49cpsozoneprimarystandard" ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "thermo49i",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo model 49i O3 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729838",
    "VocabularyId" : "233",
    "Identifier" : "thermo49i",
    "Label" : "Thermo model 49i O3 analyser",
    "Definition" : null,
    "Notation" : "thermo49i",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "thermo49w",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo model 49w O3 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729839",
    "VocabularyId" : "233",
    "Identifier" : "thermo49w",
    "Label" : "Thermo model 49w O3 analyser",
    "Definition" : null,
    "Notation" : "thermo49w",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  }, {
    "@id" : "thermo5012MAAP",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo Scientific 5012 MAAP",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729840",
    "VocabularyId" : "233",
    "Identifier" : "thermo5012MAAP",
    "Label" : "Thermo Scientific 5012 MAAP",
    "Definition" : "The Model 5012 MAAP measures the aerosol-related absorption of light and the corresponding atmospheric black carbon mass concentration. Continuous data is provided by a multiple detector setup to simultaneously measure the transmitted and the scattered light from a particle-loaded filter. Typical applications include determining ambient elemental carbon for health-related effects and aerosol light absorption for visibility monitoring (regional haze) and climate research.",
    "Notation" : "thermo5012MAAP",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "thermo5014i",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo 5014i Beta Continuous Ambient Particulate Monitor",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729841",
    "VocabularyId" : "233",
    "Identifier" : "thermo5014i",
    "Label" : "Thermo 5014i Beta Continuous Ambient Particulate Monitor",
    "Definition" : "Measure PM-10  PM-2.5 or PM-1 mass concentrations with the Thermo Scientific™ 5014i Beta Continuous Ambient Particulate Monitor. The 5014i distinguishes itself from other beta measurement methods by utilizing a continuous (non-step wise) mass measurement with a proven industry standard which provides for long-term unattended operation. To accurately address potential water bias and volatile loss  the Dynamic Heating System allows the user to hold the sample temperature at a fixed value or below a relative humidity threshold.",
    "Notation" : "thermo5014i",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6002" ]
  }, {
    "@id" : "thermo5030SHARP",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo model 5030 SHARP Particular Monitor with PM10 & PM2.5 heads",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729842",
    "VocabularyId" : "233",
    "Identifier" : "thermo5030SHARP",
    "Label" : "Thermo model 5030 SHARP Particular Monitor with PM10 & PM2.5 heads",
    "Definition" : "The Thermo Scientific™ 5030 SHARP continuously measures the mass concentration of particulate utilizing a combination of beta attenuation and light scattering technology.The only continuous (non-step wise) hybrid ambient monitor that provides high resolution measurement of airborne particulates with excellent short and long term precision.",
    "Notation" : "thermo5030SHARP",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/5", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6001", "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/6002" ]
  }, {
    "@id" : "thermoAorC",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo a or c-series",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729843",
    "VocabularyId" : "233",
    "Identifier" : "thermoAorC",
    "Label" : "Thermo a or c-series",
    "Definition" : null,
    "Notation" : "thermoAorC",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "thermoI",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Thermo i-series",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729844",
    "VocabularyId" : "233",
    "Identifier" : "thermoI",
    "Label" : "Thermo i-series",
    "Definition" : null,
    "Notation" : "thermoI",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "undetermined",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "too generic",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729845",
    "VocabularyId" : "233",
    "Identifier" : "undetermined",
    "Label" : "too generic",
    "Definition" : null,
    "Notation" : "undetermined",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "too generic" ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "unknown",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Unknown",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729846",
    "VocabularyId" : "233",
    "Identifier" : "unknown",
    "Label" : "Unknown",
    "Definition" : null,
    "Notation" : "unknown",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "unor610",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "UNOR 610 (5) - SICK",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729847",
    "VocabularyId" : "233",
    "Identifier" : "unor610",
    "Label" : "UNOR 610 (5) - SICK",
    "Definition" : "UNOR 610 (5) - SICK",
    "Notation" : "unor610",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "unor6N",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Maihak Unor 6N",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729848",
    "VocabularyId" : "233",
    "Identifier" : "unor6N",
    "Label" : "Maihak Unor 6N",
    "Definition" : null,
    "Notation" : "unor6N",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ "check pollutant" ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "varian3800",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Varian 3800",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729849",
    "VocabularyId" : "233",
    "Identifier" : "varian3800",
    "Label" : "Varian 3800",
    "Definition" : "Varian 3800",
    "Notation" : "varian3800",
    "Status" : "Valid",
    "StatusModifiedDate" : "2024-08-02",
    "AcceptedDate" : "2024-08-02",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ ]
  }, {
    "@id" : "horibaAPSA380",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APSA 380 SO2 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729985",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPSA380",
    "Label" : "Horiba model APSA 380 SO2 analyser",
    "Definition" : null,
    "Notation" : "horibaAPSA380",
    "Status" : "Valid",
    "StatusModifiedDate" : "2025-11-26",
    "AcceptedDate" : "2025-11-26",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/1" ]
  }, {
    "@id" : "horibaAPOA380",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Horiba model APOA 380 O3 analyser",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "54729986",
    "VocabularyId" : "233",
    "Identifier" : "horibaAPOA380",
    "Label" : "Horiba model APOA 380 O3 analyser",
    "Definition" : null,
    "Notation" : "horibaAPOA380",
    "Status" : "Valid",
    "StatusModifiedDate" : "2025-11-26",
    "AcceptedDate" : "2025-11-26",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ],
    "skos:editorialNote" : [ ],
    "skos:example" : [ ],
    "skos:relatedMatch" : [ ],
    "measuresPollutant" : [ "http://dd.eionet.europa.eu/vocabulary/aq/pollutant/7" ]
  } ]
}