  "@context" : {
    "@base" : "http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/",
    "skos" : "http://www.w3.org/2004/02/skos/core#",
    "concepts" : "skos:Concept",
    "prefLabel" : "skos:prefLabel",
    "broader" : "skos:broader",
    "narrower" : "skos:narrower",
    "@language" : "en",
    "VocabularyId" : "3070",
    "ContinuityId" : "4b49f08d-0d6d-3d35-a3d3-ba9872758cfd",
    "Identifier" : "BATAELIronSteelCode",
    "Label" : "BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector",
    "RegistrationStatus" : "Public draft",
    "IsWorkingCopy" : "false",
    "CheckedOutCopyId" : "0",
    "WorkingUser" : null,
    "DateModified" : "2018-01-29 17:46:18.0",
    "UserModified" : "glossioti",
    "IsNumericConceptIdentifiers" : "false",
    "VocabularyType" : "Common",
    "FolderId" : "36",
    "FolderName" : "IEDAnnexIIModule3",
    "FolderLabel" : "IED Annex II Module 3 (Sectoral spotlight of IED installation – BAT conclusion implementation)",
    "IsNotationsEqualIdentifiers" : "true",
    "Definition" : null,
    "Version" : null
  },
  "concepts" : [ {
    "@id" : "IS-2012-BAT-20-I",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Bag filter Dust < 1 - 15 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264623",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-20-I",
    "Label" : "Bag filter Dust < 1 - 15 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-20-I",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-20-II",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Advanced electrostatic precipitators Dust < 20 - 40 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264624",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-20-II",
    "Label" : "Advanced electrostatic precipitators Dust < 20 - 40 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-20-II",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-21",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Waste gas treatment with activated carbon or lignite coke injection Mercury < 0.03 - 0.05 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264625",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-21",
    "Label" : "Waste gas treatment with activated carbon or lignite coke injection Mercury < 0.03 - 0.05 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-21",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-22-I",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "BAT I - IV  Sulphur oxides (SOX) < 350 - 500 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264626",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-22-I",
    "Label" : "BAT I - IV  Sulphur oxides (SOX) < 350 - 500 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-22-I",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-22-II",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "BAT V  Sulphur oxides (SOX)   < 100 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264627",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-22-II",
    "Label" : "BAT V  Sulphur oxides (SOX)   < 100 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-22-II",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-23-I",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Process integrated measures (I.) Nitrogen oxides (NOX)   < 500 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264628",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-23-I",
    "Label" : "Process integrated measures (I.) Nitrogen oxides (NOX)   < 500 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-23-I",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-23-II",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "RAC (II.i) Nitrogen oxides (NOX)   < 250 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264629",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-23-II",
    "Label" : "RAC (II.i) Nitrogen oxides (NOX)   < 250 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-23-II",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-23-III",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "SCR (II.ii) Nitrogen oxides (NOX)   < 120 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264630",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-23-III",
    "Label" : "SCR (II.ii) Nitrogen oxides (NOX)   < 120 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-23-III",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-25-I",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Bag filter Polychlorinated dibenzodioxins/ furans (PCDD/F) < 0.05 - 0.2 ng / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264631",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-25-I",
    "Label" : "Bag filter Polychlorinated dibenzodioxins/ furans (PCDD/F) < 0.05 - 0.2 ng / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-25-I",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-25-II",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Advanced electrostatic precipitator Polychlorinated dibenzodioxins/ furans (PCDD/F) < 0.2 - 0.4 ng / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264632",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-25-II",
    "Label" : "Advanced electrostatic precipitator Polychlorinated dibenzodioxins/ furans (PCDD/F) < 0.2 - 0.4 ng / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-25-II",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-26-I",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Bag filter Dust   < 10 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264633",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-26-I",
    "Label" : "Bag filter Dust   < 10 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-26-I",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-26-II",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Electrostatic precipitator Dust   < 30 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264634",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-26-II",
    "Label" : "Electrostatic precipitator Dust   < 30 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-26-II",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-28-I",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Heavy metal precipitation, neutralisation, sand filtration Suspended solids   < 30 mg / l",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264635",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-28-I",
    "Label" : "Heavy metal precipitation, neutralisation, sand filtration Suspended solids   < 30 mg / l",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-28-I",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-28-II",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Heavy metal precipitation, neutralisation, sand filtration Chemical oxygen demand (COD)   < 100 mg / l",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264636",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-28-II",
    "Label" : "Heavy metal precipitation, neutralisation, sand filtration Chemical oxygen demand (COD)   < 100 mg / l",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-28-II",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-28-III",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Heavy metal precipitation, neutralisation, sand filtration Heavy metals   < 0.1 mg / l",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264637",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-28-III",
    "Label" : "Heavy metal precipitation, neutralisation, sand filtration Heavy metals   < 0.1 mg / l",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-28-III",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-33-I",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Crushing, grinding and drying Dust   < 20 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264638",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-33-I",
    "Label" : "Crushing, grinding and drying Dust   < 20 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-33-I",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-33-II",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "All other process steps or where all waste gases are treated together Dust < 10 - 15 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264639",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-33-II",
    "Label" : "All other process steps or where all waste gases are treated together Dust < 10 - 15 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-33-II",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-34-I",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Wet scrubber, semi-dry absorption with a subsequent dedusting system Sulphur oxides (SOX)  < 30 - 50 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264640",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-34-I",
    "Label" : "Wet scrubber, semi-dry absorption with a subsequent dedusting system Sulphur oxides (SOX)  < 30 - 50 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-34-I",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-34-II",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Wet scrubber, semi-dry absorption with a subsequent dedusting system Hydrogen fluoride (HF) < 1 - 3 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264641",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-34-II",
    "Label" : "Wet scrubber, semi-dry absorption with a subsequent dedusting system Hydrogen fluoride (HF) < 1 - 3 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-34-II",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-34-III",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Wet scrubber, semi-dry absorption with a subsequent dedusting system Hydrogen chloride (HCl) < 1 - 3 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264642",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-34-III",
    "Label" : "Wet scrubber, semi-dry absorption with a subsequent dedusting system Hydrogen chloride (HCl) < 1 - 3 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-34-III",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-39-I",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Techniques (I.)-(V.)  Suspended solids   < 50 mg / l",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264643",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-39-I",
    "Label" : "Techniques (I.)-(V.)  Suspended solids   < 50 mg / l",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-39-I",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-39-II",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Techniques (I.)-(V.)  Chemical oxygen demand (COD)   < 160 mg / l",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264644",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-39-II",
    "Label" : "Techniques (I.)-(V.)  Chemical oxygen demand (COD)   < 160 mg / l",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-39-II",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-39-III",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Techniques (I.)-(V.)  Kjeldahl nitrogen   < 45 mg / l",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264645",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-39-III",
    "Label" : "Techniques (I.)-(V.)  Kjeldahl nitrogen   < 45 mg / l",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-39-III",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-39-IV",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Techniques (I.)-(V.)  Heavy metals   < 0.55 mg / l",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264646",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-39-IV",
    "Label" : "Techniques (I.)-(V.)  Heavy metals   < 0.55 mg / l",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-39-IV",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-42",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Coal grinding plants, techniques (I.)-(II.)  Dust < 10 - 20 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264647",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-42",
    "Label" : "Coal grinding plants, techniques (I.)-(II.)  Dust < 10 - 20 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-42",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-43",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Using efficient extraction and subsequent dedusting (technique (V.) Dust < 10 - 20 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264648",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-43",
    "Label" : "Using efficient extraction and subsequent dedusting (technique (V.) Dust < 10 - 20 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-43",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-44-I",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Coal charging systems with land-based treatment of extracted gases Dust   < 5 g / t",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264649",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-44-I",
    "Label" : "Coal charging systems with land-based treatment of extracted gases Dust   < 5 g / t",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-44-I",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-44-II",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Coal charging systems with land-based treatment of extracted gases Dust   < 50 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264650",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-44-II",
    "Label" : "Coal charging systems with land-based treatment of extracted gases Dust   < 50 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-44-II",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-48-I",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Residual hydrogen sulphide (H2S) concentrations between < 300 – 1 000 mg/Nm3 when using desulphurisation by absorption systems",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264651",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-48-I",
    "Label" : "Residual hydrogen sulphide (H2S) concentrations between < 300 – 1 000 mg/Nm3 when using desulphurisation by absorption systems",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-48-I",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-23",
    "AcceptedDate" : null,
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-48-II",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Residual hydrogen sulphide (H2S) concentrations below < 10 mg/Nm3 when using wet oxidative desulphurisation",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264652",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-48-II",
    "Label" : "Residual hydrogen sulphide (H2S) concentrations below < 10 mg/Nm3 when using wet oxidative desulphurisation",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-48-II",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-23",
    "AcceptedDate" : null,
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-49-I",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Techniques (I.)-(IV.)  Sulphur oxides (SOX)  < 200 - 500 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264653",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-49-I",
    "Label" : "Techniques (I.)-(IV.)  Sulphur oxides (SOX)  < 200 - 500 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-49-I",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-49-II",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Techniques (I.)-(IV.)  Dust < 1 - 20 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264654",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-49-II",
    "Label" : "Techniques (I.)-(IV.)  Dust < 1 - 20 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-49-II",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-49-III",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Techniques (I.)-(IV.)  Nitrogen oxides (NOX) < 350 - 500 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264655",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-49-III",
    "Label" : "Techniques (I.)-(IV.)  Nitrogen oxides (NOX) < 350 - 500 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-49-III",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-49-IV",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Techniques (I.)-(IV.)  Nitrogen oxides (NOX)  500 - 650 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264656",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-49-IV",
    "Label" : "Techniques (I.)-(IV.)  Nitrogen oxides (NOX)  500 - 650 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-49-IV",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-50-I",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Bag filters Dust   < 10 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264657",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-50-I",
    "Label" : "Bag filters Dust   < 10 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-50-I",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-50-II",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Other cases Dust   < 20 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264658",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-50-II",
    "Label" : "Other cases Dust   < 20 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-50-II",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-51-I",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Coke dry quenching (CDQ) Dust   < 20 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264659",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-51-I",
    "Label" : "Coke dry quenching (CDQ) Dust   < 20 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-51-I",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-51-II",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Emission-minimised conventional wet quenching Dust   < 25 g / t",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264660",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-51-II",
    "Label" : "Emission-minimised conventional wet quenching Dust   < 25 g / t",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-51-II",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-51-III",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Coke stabilisation quenching (CSQ) Dust   < 10 g / t",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264661",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-51-III",
    "Label" : "Coke stabilisation quenching (CSQ) Dust   < 10 g / t",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-51-III",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-52",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Techniques (I.)-(II.)  Dust   < 10 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264662",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-52",
    "Label" : "Techniques (I.)-(II.)  Dust   < 10 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-52",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-56-I",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Biological waste water treatment with denitrification/nitrification; single coke oven water treatment plants Chemical oxygen demand (COD)   < 220 mg / l",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264663",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-56-I",
    "Label" : "Biological waste water treatment with denitrification/nitrification; single coke oven water treatment plants Chemical oxygen demand (COD)   < 220 mg / l",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-56-I",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-56-II",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Biological waste water treatment with denitrification/nitrification; single coke oven water treatment plants Biological oxygen demand for 5 days (BOD5)   < 20 mg / l",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264664",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-56-II",
    "Label" : "Biological waste water treatment with denitrification/nitrification; single coke oven water treatment plants Biological oxygen demand for 5 days (BOD5)   < 20 mg / l",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-56-II",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-56-III",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Biological waste water treatment with denitrification/nitrification; single coke oven water treatment plants Sulphides, easily released   < 0.1 mg / l",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264665",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-56-III",
    "Label" : "Biological waste water treatment with denitrification/nitrification; single coke oven water treatment plants Sulphides, easily released   < 0.1 mg / l",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-56-III",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-56-IV",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Biological waste water treatment with denitrification/nitrification; single coke oven water treatment plants Thiocyanate (SCN-)    < 4 mg / l",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264666",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-56-IV",
    "Label" : "Biological waste water treatment with denitrification/nitrification; single coke oven water treatment plants Thiocyanate (SCN-)    < 4 mg / l",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-56-IV",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-56-V",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Biological waste water treatment with denitrification/nitrification; single coke oven water treatment plants Cyanide (CN-), easily released   < 0.1 mg / l",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264667",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-56-V",
    "Label" : "Biological waste water treatment with denitrification/nitrification; single coke oven water treatment plants Cyanide (CN-), easily released   < 0.1 mg / l",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-56-V",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-56-VI",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Biological waste water treatment with denitrification/nitrification; single coke oven water treatment plants Polycyclic aromatic hydrocarbons (PAH)   < 0.05 mg / l",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264668",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-56-VI",
    "Label" : "Biological waste water treatment with denitrification/nitrification; single coke oven water treatment plants Polycyclic aromatic hydrocarbons (PAH)   < 0.05 mg / l",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-56-VI",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-56-VII",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Biological waste water treatment with denitrification/nitrification; single coke oven water treatment plants Phenols   < 0.5 mg / l",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264669",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-56-VII",
    "Label" : "Biological waste water treatment with denitrification/nitrification; single coke oven water treatment plants Phenols   < 0.5 mg / l",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-56-VII",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-56-VIII",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Biological waste water treatment with denitrification/nitrification; single coke oven water treatment plants Sum of ammonia-nitrogen (NH4+ - N), nitrate-nitrogen (NO3- - N) and nitrite-nitrogen (NO2- - N) < 15 - 50 mg / l",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264670",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-56-VIII",
    "Label" : "Biological waste water treatment with denitrification/nitrification; single coke oven water treatment plants Sum of ammonia-nitrogen (NH4+ - N), nitrate-nitrogen (NO3- - N) and nitrite-nitrogen (NO2- - N) < 15 - 50 mg / l",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-56-VIII",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-59",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Dust capture and dry dedusting Dust   < 20 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264671",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-59",
    "Label" : "Dust capture and dry dedusting Dust   < 20 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-59",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-61",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "BAT II  Dust < 1 - 15 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264672",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-61",
    "Label" : "BAT II  Dust < 1 - 15 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-61",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-64",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Residual dust concentration associated with BAT is < 10 mg/Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264673",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-64",
    "Label" : "Residual dust concentration associated with BAT is < 10 mg/Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-64",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-23",
    "AcceptedDate" : null,
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-65-I",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Desulphurised and dedusted surplus coke oven gas, dedusted blast furnace gas, dedusted basic oxygen furnace gas and natural gas Sulphur oxides (SOX)    < 200 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264674",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-65-I",
    "Label" : "Desulphurised and dedusted surplus coke oven gas, dedusted blast furnace gas, dedusted basic oxygen furnace gas and natural gas Sulphur oxides (SOX)    < 200 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-65-I",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-65-II",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Desulphurised and dedusted surplus coke oven gas, dedusted blast furnace gas, dedusted basic oxygen furnace gas and natural gas Dust   < 10 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264675",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-65-II",
    "Label" : "Desulphurised and dedusted surplus coke oven gas, dedusted blast furnace gas, dedusted basic oxygen furnace gas and natural gas Dust   < 10 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-65-II",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-65-III",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Desulphurised and dedusted surplus coke oven gas, dedusted blast furnace gas, dedusted basic oxygen furnace gas and natural gas Nitrogen oxides (NOX)   < 100 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264676",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-65-III",
    "Label" : "Desulphurised and dedusted surplus coke oven gas, dedusted blast furnace gas, dedusted basic oxygen furnace gas and natural gas Nitrogen oxides (NOX)   < 100 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-65-III",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-67-I",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Flocculation, sedimentation, reduction of easily released cyanide Suspended solids   < 30 mg / l",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264677",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-67-I",
    "Label" : "Flocculation, sedimentation, reduction of easily released cyanide Suspended solids   < 30 mg / l",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-67-I",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-67-II",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Flocculation, sedimentation, reduction of easily released cyanide Iron   < 5 mg / l",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264678",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-67-II",
    "Label" : "Flocculation, sedimentation, reduction of easily released cyanide Iron   < 5 mg / l",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-67-II",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-67-III",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Flocculation, sedimentation, reduction of easily released cyanide Lead   < 0.5 mg / l",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264679",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-67-III",
    "Label" : "Flocculation, sedimentation, reduction of easily released cyanide Lead   < 0.5 mg / l",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-67-III",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-67-IV",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Flocculation, sedimentation, reduction of easily released cyanide Zinc   < 2 mg / l",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264680",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-67-IV",
    "Label" : "Flocculation, sedimentation, reduction of easily released cyanide Zinc   < 2 mg / l",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-67-IV",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-67-V",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Flocculation, sedimentation, reduction of easily released cyanide Cyanide (CN-), easily released   < 0.4 mg / l",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264681",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-67-V",
    "Label" : "Flocculation, sedimentation, reduction of easily released cyanide Cyanide (CN-), easily released   < 0.4 mg / l",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-67-V",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-76-I",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "BAT I  Dust  10 - 30 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264682",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-76-I",
    "Label" : "BAT I  Dust  10 - 30 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-76-I",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-76-II",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "BAT II  Dust   < 50 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264683",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-76-II",
    "Label" : "BAT II  Dust   < 50 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-76-II",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-78-I",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Bag filter Dust < 1 - 15 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264684",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-78-I",
    "Label" : "Bag filter Dust < 1 - 15 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-78-I",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-78-II",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "ESP Dust   < 20 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264685",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-78-II",
    "Label" : "ESP Dust   < 20 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-78-II",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-78-III",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Bag filter Dust < 1 - 10 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264686",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-78-III",
    "Label" : "Bag filter Dust < 1 - 10 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-78-III",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-78-IV",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "ESP Dust   < 20 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264687",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-78-IV",
    "Label" : "ESP Dust   < 20 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-78-IV",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-79",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "BAT I  Dust < 10 - 20 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264688",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-79",
    "Label" : "BAT I  Dust < 10 - 20 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-79",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-81-I",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Techniques (I.)-(III.)  Suspended solids   < 20 mg / l",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264689",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-81-I",
    "Label" : "Techniques (I.)-(III.)  Suspended solids   < 20 mg / l",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-81-I",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-81-II",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Techniques (I.)-(III.)  Iron   < 5 mg / l",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264690",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-81-II",
    "Label" : "Techniques (I.)-(III.)  Iron   < 5 mg / l",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-81-II",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-81-III",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Techniques (I.)-(III.)  Zinc   < 2 mg / l",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264691",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-81-III",
    "Label" : "Techniques (I.)-(III.)  Zinc   < 2 mg / l",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-81-III",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-81-IV",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Techniques (I.)-(III.)  Nickel   < 0.5 mg / l",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264692",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-81-IV",
    "Label" : "Techniques (I.)-(III.)  Nickel   < 0.5 mg / l",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-81-IV",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-81-V",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Techniques (I.)-(III.)  Total chromium   < 0.5 mg / l",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264693",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-81-V",
    "Label" : "Techniques (I.)-(III.)  Total chromium   < 0.5 mg / l",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-81-V",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-81-VI",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Techniques (I.)-(III.)  Total hydrocarbons   < 5 mg / l",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264694",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-81-VI",
    "Label" : "Techniques (I.)-(III.)  Total hydrocarbons   < 5 mg / l",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-81-VI",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-88-I",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Techniques (I.)-(III.)  and dedusting by bag filter Dust   < 5 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264695",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-88-I",
    "Label" : "Techniques (I.)-(III.)  and dedusting by bag filter Dust   < 5 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-88-I",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-88-II",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Techniques (I.)-(III.)  and dedusting by bag filter Mercury   < 0.05 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264696",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-88-II",
    "Label" : "Techniques (I.)-(III.)  and dedusting by bag filter Mercury   < 0.05 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-88-II",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-89",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Techniques (I.)-(III.)  Polychlorinated dibenzodioxins/ furans (PCDD/F)   < 0.1 ng / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264697",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-89",
    "Label" : "Techniques (I.)-(III.)  Polychlorinated dibenzodioxins/ furans (PCDD/F)   < 0.1 ng / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-89",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-90",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "BAT I Dust < 10 - 20 mg / Nm3",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264698",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-90",
    "Label" : "BAT I Dust < 10 - 20 mg / Nm3",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-90",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-92-I",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Techniques (I.)-(III.)  Suspended solids   < 20 mg / l",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264699",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-92-I",
    "Label" : "Techniques (I.)-(III.)  Suspended solids   < 20 mg / l",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-92-I",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-92-II",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Techniques (I.)-(III.)  Iron   < 5 mg / l",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264700",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-92-II",
    "Label" : "Techniques (I.)-(III.)  Iron   < 5 mg / l",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-92-II",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-92-III",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Techniques (I.)-(III.)  Zinc   < 2 mg / l",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264701",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-92-III",
    "Label" : "Techniques (I.)-(III.)  Zinc   < 2 mg / l",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-92-III",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-92-IV",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Techniques (I.)-(III.)  Nickel   < 0.5 mg / l",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264702",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-92-IV",
    "Label" : "Techniques (I.)-(III.)  Nickel   < 0.5 mg / l",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-92-IV",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-92-V",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Techniques (I.)-(III.)  Total chromium   < 0.5 mg / l",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264703",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-92-V",
    "Label" : "Techniques (I.)-(III.)  Total chromium   < 0.5 mg / l",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-92-V",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  }, {
    "@id" : "IS-2012-BAT-92-VI",
    "@type" : "skos:Concept",
    "prefLabel" : [ {
      "@value" : "Techniques (I.)-(III.)  Total hydrocarbons   < 5 mg / l",
      "@language" : "en"
    } ],
    "VocabularyConceptId" : "6264704",
    "VocabularyId" : "3070",
    "Identifier" : "IS-2012-BAT-92-VI",
    "Label" : "Techniques (I.)-(III.)  Total hydrocarbons   < 5 mg / l",
    "Definition" : null,
    "Notation" : "IS-2012-BAT-92-VI",
    "Status" : "Valid",
    "StatusModifiedDate" : "2018-01-11",
    "AcceptedDate" : "2018-01-11",
    "NotAcceptedDate" : null,
    "broader" : [ ],
    "narrower" : [ ]
  } ]
}