<?xml version="1.0" encoding="UTF-8"?>
<codelist xmlns:xsd="http://www.w3.org/2001/XMLSchema" xmlns:xs="http://www.w3.org/2001/XMLSchema" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="http://inspire.ec.europa.eu/draft-schemas/registry/0.3/codelist.xsd" id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
<status id="http://inspire.ec.europa.eu/registry/status/submitted">
<label xml:lang="en">Submitted</label></status>
<extensibility id="http://inspire.ec.europa.eu/registry/extensibility/none">
<label xml:lang="en">None</label></extensibility>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<containeditems>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-20-I">
<label xml:lang="en">Bag filter Dust &lt; 1 - 15 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-20-II">
<label xml:lang="en">Advanced electrostatic precipitators Dust &lt; 20 - 40 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-21">
<label xml:lang="en">Waste gas treatment with activated carbon or lignite coke injection Mercury &lt; 0.03 - 0.05 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-22-I">
<label xml:lang="en">BAT I - IV  Sulphur oxides (SOX) &lt; 350 - 500 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-22-II">
<label xml:lang="en">BAT V  Sulphur oxides (SOX)   &lt; 100 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-23-I">
<label xml:lang="en">Process integrated measures (I.) Nitrogen oxides (NOX)   &lt; 500 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-23-II">
<label xml:lang="en">RAC (II.i) Nitrogen oxides (NOX)   &lt; 250 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-23-III">
<label xml:lang="en">SCR (II.ii) Nitrogen oxides (NOX)   &lt; 120 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-25-I">
<label xml:lang="en">Bag filter Polychlorinated dibenzodioxins/ furans (PCDD/F) &lt; 0.05 - 0.2 ng / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-25-II">
<label xml:lang="en">Advanced electrostatic precipitator Polychlorinated dibenzodioxins/ furans (PCDD/F) &lt; 0.2 - 0.4 ng / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-26-I">
<label xml:lang="en">Bag filter Dust   &lt; 10 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-26-II">
<label xml:lang="en">Electrostatic precipitator Dust   &lt; 30 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-28-I">
<label xml:lang="en">Heavy metal precipitation, neutralisation, sand filtration Suspended solids   &lt; 30 mg / l</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-28-II">
<label xml:lang="en">Heavy metal precipitation, neutralisation, sand filtration Chemical oxygen demand (COD)   &lt; 100 mg / l</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-28-III">
<label xml:lang="en">Heavy metal precipitation, neutralisation, sand filtration Heavy metals   &lt; 0.1 mg / l</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-33-I">
<label xml:lang="en">Crushing, grinding and drying Dust   &lt; 20 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-33-II">
<label xml:lang="en">All other process steps or where all waste gases are treated together Dust &lt; 10 - 15 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-34-I">
<label xml:lang="en">Wet scrubber, semi-dry absorption with a subsequent dedusting system Sulphur oxides (SOX)  &lt; 30 - 50 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-34-II">
<label xml:lang="en">Wet scrubber, semi-dry absorption with a subsequent dedusting system Hydrogen fluoride (HF) &lt; 1 - 3 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-34-III">
<label xml:lang="en">Wet scrubber, semi-dry absorption with a subsequent dedusting system Hydrogen chloride (HCl) &lt; 1 - 3 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-39-I">
<label xml:lang="en">Techniques (I.)-(V.)  Suspended solids   &lt; 50 mg / l</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-39-II">
<label xml:lang="en">Techniques (I.)-(V.)  Chemical oxygen demand (COD)   &lt; 160 mg / l</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-39-III">
<label xml:lang="en">Techniques (I.)-(V.)  Kjeldahl nitrogen   &lt; 45 mg / l</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-39-IV">
<label xml:lang="en">Techniques (I.)-(V.)  Heavy metals   &lt; 0.55 mg / l</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-42">
<label xml:lang="en">Coal grinding plants, techniques (I.)-(II.)  Dust &lt; 10 - 20 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-43">
<label xml:lang="en">Using efficient extraction and subsequent dedusting (technique (V.) Dust &lt; 10 - 20 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-44-I">
<label xml:lang="en">Coal charging systems with land-based treatment of extracted gases Dust   &lt; 5 g / t</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-44-II">
<label xml:lang="en">Coal charging systems with land-based treatment of extracted gases Dust   &lt; 50 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-48-I">
<label xml:lang="en">Residual hydrogen sulphide (H2S) concentrations between &lt; 300 – 1 000 mg/Nm3 when using desulphurisation by absorption systems</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-48-II">
<label xml:lang="en">Residual hydrogen sulphide (H2S) concentrations below &lt; 10 mg/Nm3 when using wet oxidative desulphurisation</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-49-I">
<label xml:lang="en">Techniques (I.)-(IV.)  Sulphur oxides (SOX)  &lt; 200 - 500 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-49-II">
<label xml:lang="en">Techniques (I.)-(IV.)  Dust &lt; 1 - 20 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-49-III">
<label xml:lang="en">Techniques (I.)-(IV.)  Nitrogen oxides (NOX) &lt; 350 - 500 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-49-IV">
<label xml:lang="en">Techniques (I.)-(IV.)  Nitrogen oxides (NOX)  500 - 650 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-50-I">
<label xml:lang="en">Bag filters Dust   &lt; 10 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-50-II">
<label xml:lang="en">Other cases Dust   &lt; 20 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-51-I">
<label xml:lang="en">Coke dry quenching (CDQ) Dust   &lt; 20 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-51-II">
<label xml:lang="en">Emission-minimised conventional wet quenching Dust   &lt; 25 g / t</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-51-III">
<label xml:lang="en">Coke stabilisation quenching (CSQ) Dust   &lt; 10 g / t</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-52">
<label xml:lang="en">Techniques (I.)-(II.)  Dust   &lt; 10 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-56-I">
<label xml:lang="en">Biological waste water treatment with denitrification/nitrification; single coke oven water treatment plants Chemical oxygen demand (COD)   &lt; 220 mg / l</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-56-II">
<label xml:lang="en">Biological waste water treatment with denitrification/nitrification; single coke oven water treatment plants Biological oxygen demand for 5 days (BOD5)   &lt; 20 mg / l</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-56-III">
<label xml:lang="en">Biological waste water treatment with denitrification/nitrification; single coke oven water treatment plants Sulphides, easily released   &lt; 0.1 mg / l</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-56-IV">
<label xml:lang="en">Biological waste water treatment with denitrification/nitrification; single coke oven water treatment plants Thiocyanate (SCN-)    &lt; 4 mg / l</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-56-V">
<label xml:lang="en">Biological waste water treatment with denitrification/nitrification; single coke oven water treatment plants Cyanide (CN-), easily released   &lt; 0.1 mg / l</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-56-VI">
<label xml:lang="en">Biological waste water treatment with denitrification/nitrification; single coke oven water treatment plants Polycyclic aromatic hydrocarbons (PAH)   &lt; 0.05 mg / l</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-56-VII">
<label xml:lang="en">Biological waste water treatment with denitrification/nitrification; single coke oven water treatment plants Phenols   &lt; 0.5 mg / l</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-56-VIII">
<label xml:lang="en">Biological waste water treatment with denitrification/nitrification; single coke oven water treatment plants Sum of ammonia-nitrogen (NH4+ - N), nitrate-nitrogen (NO3- - N) and nitrite-nitrogen (NO2- - N) &lt; 15 - 50 mg / l</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-59">
<label xml:lang="en">Dust capture and dry dedusting Dust   &lt; 20 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-61">
<label xml:lang="en">BAT II  Dust &lt; 1 - 15 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-64">
<label xml:lang="en">Residual dust concentration associated with BAT is &lt; 10 mg/Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-65-I">
<label xml:lang="en">Desulphurised and dedusted surplus coke oven gas, dedusted blast furnace gas, dedusted basic oxygen furnace gas and natural gas Sulphur oxides (SOX)    &lt; 200 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-65-II">
<label xml:lang="en">Desulphurised and dedusted surplus coke oven gas, dedusted blast furnace gas, dedusted basic oxygen furnace gas and natural gas Dust   &lt; 10 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-65-III">
<label xml:lang="en">Desulphurised and dedusted surplus coke oven gas, dedusted blast furnace gas, dedusted basic oxygen furnace gas and natural gas Nitrogen oxides (NOX)   &lt; 100 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-67-I">
<label xml:lang="en">Flocculation, sedimentation, reduction of easily released cyanide Suspended solids   &lt; 30 mg / l</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-67-II">
<label xml:lang="en">Flocculation, sedimentation, reduction of easily released cyanide Iron   &lt; 5 mg / l</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-67-III">
<label xml:lang="en">Flocculation, sedimentation, reduction of easily released cyanide Lead   &lt; 0.5 mg / l</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-67-IV">
<label xml:lang="en">Flocculation, sedimentation, reduction of easily released cyanide Zinc   &lt; 2 mg / l</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-67-V">
<label xml:lang="en">Flocculation, sedimentation, reduction of easily released cyanide Cyanide (CN-), easily released   &lt; 0.4 mg / l</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-76-I">
<label xml:lang="en">BAT I  Dust  10 - 30 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-76-II">
<label xml:lang="en">BAT II  Dust   &lt; 50 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-78-I">
<label xml:lang="en">Bag filter Dust &lt; 1 - 15 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-78-II">
<label xml:lang="en">ESP Dust   &lt; 20 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-78-III">
<label xml:lang="en">Bag filter Dust &lt; 1 - 10 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-78-IV">
<label xml:lang="en">ESP Dust   &lt; 20 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-79">
<label xml:lang="en">BAT I  Dust &lt; 10 - 20 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-81-I">
<label xml:lang="en">Techniques (I.)-(III.)  Suspended solids   &lt; 20 mg / l</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-81-II">
<label xml:lang="en">Techniques (I.)-(III.)  Iron   &lt; 5 mg / l</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-81-III">
<label xml:lang="en">Techniques (I.)-(III.)  Zinc   &lt; 2 mg / l</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-81-IV">
<label xml:lang="en">Techniques (I.)-(III.)  Nickel   &lt; 0.5 mg / l</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-81-V">
<label xml:lang="en">Techniques (I.)-(III.)  Total chromium   &lt; 0.5 mg / l</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-81-VI">
<label xml:lang="en">Techniques (I.)-(III.)  Total hydrocarbons   &lt; 5 mg / l</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-88-I">
<label xml:lang="en">Techniques (I.)-(III.)  and dedusting by bag filter Dust   &lt; 5 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-88-II">
<label xml:lang="en">Techniques (I.)-(III.)  and dedusting by bag filter Mercury   &lt; 0.05 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-89">
<label xml:lang="en">Techniques (I.)-(III.)  Polychlorinated dibenzodioxins/ furans (PCDD/F)   &lt; 0.1 ng / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-90">
<label xml:lang="en">BAT I Dust &lt; 10 - 20 mg / Nm3</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-92-I">
<label xml:lang="en">Techniques (I.)-(III.)  Suspended solids   &lt; 20 mg / l</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-92-II">
<label xml:lang="en">Techniques (I.)-(III.)  Iron   &lt; 5 mg / l</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-92-III">
<label xml:lang="en">Techniques (I.)-(III.)  Zinc   &lt; 2 mg / l</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-92-IV">
<label xml:lang="en">Techniques (I.)-(III.)  Nickel   &lt; 0.5 mg / l</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-92-V">
<label xml:lang="en">Techniques (I.)-(III.)  Total chromium   &lt; 0.5 mg / l</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
<value id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode/IS-2012-BAT-92-VI">
<label xml:lang="en">Techniques (I.)-(III.)  Total hydrocarbons   &lt; 5 mg / l</label>
<status id="http://inspire.ec.europa.eu/registry/status/valid">
<label xml:lang="en">Valid</label>
</status>
<register id="http://dd.eionet.europa.eu/vocabularies">
<label xml:lang="en">Data Dictionary Vocabularies</label>
<registry id="http://dd.eionet.europa.eu">
<label xml:lang="en">Eionet Data Dictionary</label>
</registry>
</register>
<codelist id="http://dd.eionet.europa.eu/vocabulary/IEDAnnexIIModule3/BATAELIronSteelCode">
<label xml:lang="en">BAT-AELs mentioned in the BAT conclusions Decision 2012/135/EU for the Iron and Steel sector</label>
</codelist>
</value>
</containeditems>
</codelist>
